{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H4P32AB","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H4P32AB","canonicalUrl":"https://aoctrl.com/schneider/C60H4P32AB","factsUrl":"https://aoctrl.com/api/mcp/products/C60H4P32AB","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H, miniature circuit-breaker, C60H4P32AB, 4P, 32 A, B curve, 10 kA Icn at 230/400 V AC, 35 mm DIN rail mount.","salesMarkdown":"The C60H4P32AB is a 4-pole miniature circuit-breaker from the Schneider Multi9 C60H series, rated 32 A at 30 °C with a B tripping curve (3–5 x In magnetic trip). It breaks up to 10 kA Icn under EN 60898 at 230/400 V AC, and up to 30 kA Icu under IEC 60947-2 at 230–240 V AC — covering both residential and industrial fault-current requirements. The C60H4P32AB's Ics (service breaking capacity) is 7.5 kA at 230/400 V per EN 60898, and 15 kA at 230–240 V per IEC 60947-2. That means after clearing a fault at these levels the breaker remains usable — not just safe but functional — which matters for selectivity studies and downstream coordination in a multi-level distribution board. Occupies 8 x 9 mm pitches (72 mm wide), 81 mm tall, 73 mm deep. Listed as current production (active lifecycle stage). The C60H series is a long-running platform; no official successor has been announced.","metaTitle":"C60H4P32AB Miniature Circuit Breaker, 32 A, Curve B, 10 kA,","metaDescription":"C60H4P32AB MCB from Schneider Electric Multi9 range. 32 A rated current, curve B, 10 kA breaking capacity (EN 60898). 4 poles, DIN rail mount. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"IEC 60947-2 EN 60898","Curve code":"B","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Range of product":"C60","Breaking capacity":"10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 3.5 N.m upside 3.5 N.m downside","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"32 A at 30 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"12...440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H4P32AB/miniature-circuit-breaker-c60h-4-poles-32-a-b-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H4P32AB/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of C60H4P32AB?","answer":"The C60H4P32AB has a rated breaking capacity of 10 kA Icn at 230/400 V AC per EN 60898, and up to 30 kA Icu at 230–240 V AC per IEC 60947-2. Service breaking capacity (Ics) is 7.5 kA at 230/400 V per EN 60898."},{"question":"What is the tripping curve and magnetic threshold?","answer":"B curve, with magnetic tripping between 3 and 5 times the rated current (In). That means for a 32 A breaker, the magnetic trip activates between 96 A and 160 A, suited for resistive and general-purpose loads where inrush is low."},{"question":"Where can I buy the C60H4P32AB?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H4P32AB","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H4P32AB when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}