{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H4P3AD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H4P3AD","canonicalUrl":"https://aoctrl.com/schneider/C60H4P3AD","factsUrl":"https://aoctrl.com/api/mcp/products/C60H4P3AD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H, C60H4P3AD, 4-pole miniature circuit breaker, D curve, 3 A rated current, 10 kA breaking capacity at 230/400 V AC, DIN rail mount.","salesMarkdown":"The Schneider Electric C60H4P3AD is a 4-pole miniature circuit breaker from the Multi9 C60H series, rated 3 A at 40 °C with a D tripping curve. Under IEC 60947-2, the ultimate breaking capacity (Icu) reaches 15 kA at 400...415 V AC, 30 kA at 230...240 V AC, and 40 kA at 125 V DC for 3-pole connection. The service breaking capacity (Ics) is 7.5 kA at 230/400 V AC per EN 60898, confirming the breaker clears faults repeatedly within its rating. Occupies 8 modules of 9 mm pitch on the DIN rail — 72 mm wide, 81 mm tall, 73 mm deep. The toggle provides local ON/OFF indication with a contact position indicator for isolation verification per IEC 60947-2. Separate earth-leakage protection block can be added alongside.","metaTitle":"C60H4P3AD MCB, 4P, D Curve, 3 A, 10 kA, Multi9","metaDescription":"Schneider Electric C60H4P3AD miniature circuit breaker, 4 poles, D curve, 3 A rated, 10 kA breaking capacity at 230/400 V AC. Multi9 range, DIN rail mount. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"EN 60898 IEC 60947-2","Curve code":"D","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Range of product":"C60","Breaking capacity":"10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 2 N.m upside 2 N.m downside","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"3 A at 40 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid","Magnetic tripping limit":"10...14 x In","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"12...440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H4P3AD/miniature-circuit-breaker-c60h-4-poles-3-a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H4P3AD/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of C60H4P3AD?","answer":"The Icn is 10 kA at 230/400 V AC per EN 60898. Under IEC 60947-2, Icu reaches 15 kA at 400...415 V AC and 30 kA at 230...240 V AC. Ics is 7.5 kA at 230/400 V AC per EN 60898."},{"question":"What is the D curve on this MCB for?","answer":"The D curve trips magnetically at 10 to 14 times the rated current (3 A), so it handles high inrush loads like motor starters, transformers, or welding equipment without nuisance tripping."},{"question":"Where can I buy C60H4P3AD?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does C60H4P3AD carry?","answer":"It complies with EN 60898 and IEC 60947-2. Tropicalisation level 2 per IEC 60068-1. The product is suitable for isolation per IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H4P3AD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H4P3AD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}