{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H4P4AD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H4P4AD","canonicalUrl":"https://aoctrl.com/schneider/C60H4P4AD","factsUrl":"https://aoctrl.com/api/mcp/products/C60H4P4AD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H series, C60H4P4AD miniature circuit breaker, D curve, 4 A rated current, 4 poles, 10 kA Icn at 230/400 V AC.","salesMarkdown":"The C60H4P4AD is a 4-pole miniature circuit breaker from Schneider Electric's Multi9 C60H range, rated 4 A at 40 °C with a D trip curve. The 10 kA Icn at 230/400 V AC (EN 60898) is the rated short-circuit capacity for a domestic or light commercial distribution board; the higher Icu ratings under IEC 60947-2 (up to 30 kA at 230–240 V AC) apply when the breaker is used in an industrial panel with a higher prospective fault current. The 4 A rating governs continuous load; on a 4-pole configuration, all four poles are protected, so it suits a three-phase plus neutral distribution circuit. The 72 mm width occupies 8 modules of 9 mm pitch — standard for a 4-pole MCB in a distribution board. The 73 mm depth fits standard shallow enclosures.","metaTitle":"Schneider Electric C60H4P4AD MCB, D Curve, 4 A, 4P, 10 kA","metaDescription":"Schneider Electric C60H4P4AD Multi9 C60H miniature circuit breaker, D curve, 4 A rated, 4 poles, 10 kA Icn at 230/400 V AC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"EN 60898 IEC 60947-2","Curve code":"D","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC DC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Range of product":"C60","Breaking capacity":"10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 2 N.m upside 2 N.m downside","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"4 A at 40 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid","Magnetic tripping limit":"10...14 x In","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"12...440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H4P4AD/miniature-circuit-breaker-c60h-4-poles-4-a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H4P4AD/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to C60H4P4AD in the same family?","answer":"Within the Multi9 C60H range, the closest sibling is a different current rating or pole configuration — the C60H4P4AD is a 4 A, 4-pole D-curve variant. A 6 A or 10 A version in the same 4-pole D-curve footprint would swap in if the load requires a higher continuous rating, but the 4 A version is the one specified for the BOM line."},{"question":"Where can I buy C60H4P4AD and how is it quoted?","answer":"The C60H4P4AD is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What compliance documentation does Schneider Electric provide for C60H4P4AD?","answer":"The C60H4P4AD is certified to EN 60898 and IEC 60947-2, carries CE marking, and is suitable for isolation per IEC 60947-2. The manufacturer provides a declaration of conformity; RoHS and REACH compliance documentation is available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H4P4AD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H4P4AD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}