{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H4P50AD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H4P50AD","canonicalUrl":"https://aoctrl.com/schneider/C60H4P50AD","factsUrl":"https://aoctrl.com/api/mcp/products/C60H4P50AD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H series, C60H4P50AD miniature circuit breaker, 4-pole, D-curve, 50 A rated, 10 kA breaking capacity per EN 60898.","salesMarkdown":"The C60H4P50AD is a 4-pole miniature circuit breaker from the Schneider Multi9 C60 range, rated 50 A at 40 °C with a D-curve magnetic trip (10–14 × In). That D-curve means it tolerates the high inrush of motor, transformer, or welding loads without nuisance tripping — the magnetic release only fires at 10 to 14 times the rated current, so a 50 A breaker won't pop on a 300 A motor start that clears in a few cycles. The 10 kA Icn at 230/400 V AC per EN 60898 is the standard household/commercial interrupting rating; the IEC 60947-2 ratings go higher (up to 50 kA Icu at 250 V DC 4P) for industrial panel duty. Thermal-magnetic trip technology covers both overload (thermal bimetal) and short-circuit (solenoid) protection in one unit. Snaps onto 35 mm symmetrical DIN rail — standard for any distribution board or industrial enclosure. At 72 mm wide (8 × 9 mm pitches), it occupies four modular spaces, so check your rail fill before slotting it in. The fixed mounting mode and toggle control are straightforward for panel builders; ON/OFF indication and a contact position indicator give a quick visual on status without needing a meter. EN 60898 covers the household/residential rating (10 kA Icn at 230/400 V), while IEC 60947-2 provides the industrial performance grades (higher Icu values, isolation suitability).","metaTitle":"Schneider C60H4P50AD MCB, 50A D-curve, 4P, Multi9","metaDescription":"Schneider Electric C60H4P50AD miniature circuit breaker, 50 A rated, D-curve, 4 poles, 10 kA breaking capacity per EN 60898. Multi9 range. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"EN 60898 IEC 60947-2","Curve code":"D","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC DC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Range of product":"C60","Breaking capacity":"10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 3.5 N.m upside 3.5 N.m downside","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"50 A at 40 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid","Magnetic tripping limit":"10...14 x In","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"12...440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H4P50AD/miniature-circuit-breaker-c60h-4-poles-50-a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H4P50AD/alternatives.json"},"ai":{"faq":[{"question":"How do I get pricing and availability for C60H4P50AD?","answer":"Pricing and availability are confirmed at quote time. Submit an RFQ through this listing; the part is sourced to order through independent distribution."},{"question":"What is the closest alternative to C60H4P50AD in the same family?","answer":"Within the Multi9 C60 range, the closest alternative would be a 50 A 4-pole breaker with a different curve (B or C) if the D-curve's 10–14 × In magnetic trip is not needed for your load. No pin-compatible drop-in with identical ratings exists outside the D-curve variant."},{"question":"What is C60H4P50AD's depth?","answer":"73 mm depth, with a width of 72 mm and height of 81 mm."},{"question":"What compliance documentation does this breaker carry?","answer":"Certified to EN 60898 and IEC 60947-2. Suitable for isolation per IEC 60947-2. Tropicalisation class 2 per IEC 60068-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H4P50AD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H4P50AD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}