{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H4P63AC","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H4P63AC","canonicalUrl":"https://aoctrl.com/schneider/C60H4P63AC","factsUrl":"https://aoctrl.com/api/mcp/products/C60H4P63AC","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H C60H4P63AC, miniature circuit breaker, 4P, 63 A, C curve, 10 kA Icn at 230/400 V AC, thermal-magnetic trip, DIN rail mount.","salesMarkdown":"The C60H4P63AC is a 4-pole miniature circuit breaker from the Multi9 C60 range, rated 63 A at 30 °C with a C curve (magnetic trip 5–10 × In). The 10 kA Icn at 230/400 V AC (EN 60898) is the standard interrupting rating for a residential or light commercial distribution board; the higher Icu ratings under IEC 60947-2 (up to 50 kA at 250 V DC 4P) tell you it can also serve in an industrial panel where the prospective fault current is higher, as long as the service breaking capacity (Ics) is coordinated downstream. The 4-pole version isolates all live conductors in a three-phase plus neutral system — common for TN or TT earthing schemes where you want full disconnection. The 72 mm width (8 × 9 mm pitches) fits standard distribution board cutouts. The toggle provides local ON/OFF indication and a contact position indicator confirms isolation status — useful for lockout/tagout verification. Separate earth-leakage block (Vigi) can be added on the downstream side if RCD protection is needed.","metaTitle":"Schneider Electric C60H4P63AC MCB, C Curve, 63 A, 4P, Multi9","metaDescription":"Schneider Electric C60H4P63AC miniature circuit breaker, 63 A, C curve, 4 poles, 10 kA breaking capacity, IEC 60947-2/EN 60898. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"IEC 60947-2 EN 60898","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC DC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Range of product":"C60","Breaking capacity":"10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 3.5 N.m upside 3.5 N.m downside","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"63 A at 30 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"12...440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H4P63AC/miniature-circuit-breaker-c60h-4-poles-63-a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H4P63AC/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of C60H4P63AC?","answer":"10 kA Icn at 230/400 V AC (EN 60898) and up to 50 kA Icu at 250 V DC 4P (IEC 60947-2). The Ics (service breaking capacity) ranges from 5 kA at 440 V AC to 15 kA at 230–240 V AC."},{"question":"What terminals does C60H4P63AC accept?","answer":"Tunnel-type terminals accept up to 35 mm² rigid or 25 mm² flexible conductors. Tightening torque is 3.5 N·m."},{"question":"Where can I buy C60H4P63AC?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H4P63AC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H4P63AC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}