{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H4P63AD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H4P63AD","canonicalUrl":"https://aoctrl.com/schneider/C60H4P63AD","factsUrl":"https://aoctrl.com/api/mcp/products/C60H4P63AD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H series, C60H4P63AD, 4-pole miniature circuit breaker, D curve, 63 A rated current at 40 °C, thermal-magnetic trip, breaking capacity 10 kA Icn (EN 60898) at 230/400 V AC.","salesMarkdown":"The C60H4P63AD is a 4-pole miniature circuit breaker from the Schneider Multi9 C60H series, rated 63 A at 40 °C with a D tripping curve. The 4-pole version (4P) switches all four poles simultaneously, used on three-phase plus neutral circuits or DC applications where full isolation is required. Breaking capacity is the key safety spec: 10 kA Icn at 230/400 V AC per EN 60898, and higher Icu values per IEC 60947-2 — up to 50 kA at 250 V DC for the 4-pole configuration. The Icn rating (10 kA) is the standard for distribution boards under EN 60898; the Icu ratings (15 kA at 400...415 V AC, 30 kA at 230...240 V AC) apply when the breaker is specified to IEC 60947-2 for industrial panels. The Ics (service breaking capacity) ranges from 5 kA to 15 kA depending on voltage — this is the capacity the breaker can clear and still be reused, not just survive once. At 72 mm wide (8 x 9 mm pitches), it occupies 8 module spaces in a distribution board or enclosure. Depth is 73 mm, height 81 mm — check gland plate clearance if the enclosure is shallow. The fixed mounting mode means it clips onto the rail and stays put — no DIN-rail adapter or additional bracket needed. Dual-certified to IEC 60947-2 (industrial) and EN 60898 (domestic/similar) — the IEC 60947-2 rating governs industrial panel use; EN 60898 applies when installed in distribution boards to the residential/commercial standard. Relative humidity tolerance is 95 % at 55 °C. Maximum operating altitude is 2000 m without derating. Earth-leakage protection requires a separate residual current block (not integrated).","metaTitle":"Schneider Electric C60H4P63AD MCB, D Curve, 63 A, 4P, Multi9","metaDescription":"Schneider Electric C60H4P63AD miniature circuit breaker, D curve, 63 A rated at 40 °C, 4 poles, Multi9 range. IEC 60947-2 / EN 60898. Sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"IEC 60947-2 EN 60898","Curve code":"D","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Range of product":"C60","Breaking capacity":"10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 3.5 N.m upside 3.5 N.m downside","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"63 A at 40 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid","Magnetic tripping limit":"10...14 x In","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"12...440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H4P63AD/miniature-circuit-breaker-c60h-4-poles-63-a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H4P63AD/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for C60H4P63AD?","answer":"The C60H4P63AD is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit a request for quote to get a firm price and lead time for your quantity."},{"question":"What is the closest alternative to C60H4P63AD in the same family?","answer":"Within the Multi9 C60H series, the closest alternative would be a different current rating or pole count — for example, the C60H4P40AD (40 A, D curve, 4P) or C60H4P50AD (50 A, D curve, 4P). These share the same physical footprint, DIN-rail mount, and breaking capacity ratings. For a different curve, the C60H4P63AC (C curve, 63 A, 4P) offers the same current but with a lower magnetic trip threshold (5-10 x In) for general-purpose loads without high inrush."},{"question":"What is C60H4P63AD's listed depth?","answer":"The depth is 73 mm. Combined with a width of 72 mm (8 x 9 mm pitches) and height of 81 mm, it fits standard distribution board cutouts and enclosures with adequate gland plate clearance."},{"question":"What compliance documentation does Schneider provide for C60H4P63AD?","answer":"The breaker is certified to IEC 60947-2 and EN 60898. It carries tropicalisation class 2 per IEC 60068-1. For RoHS, REACH, and UL documentation, Schneider Electric provides declarations of conformity and material compliance sheets through their product documentation portal — these are typically available for download by order code."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H4P63AD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H4P63AD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}