{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H4P6AB","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H4P6AB","canonicalUrl":"https://aoctrl.com/schneider/C60H4P6AB","factsUrl":"https://aoctrl.com/api/mcp/products/C60H4P6AB","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H, miniature circuit breaker, 4 poles, 6 A rated current, B curve, 10 kA breaking capacity per EN 60898, 35 mm DIN rail mount.","salesMarkdown":"The Schneider Electric C60H4P6AB is a 4-pole miniature circuit breaker from the Multi9 C60H series, rated 6 A at 30 °C with a B tripping curve (3–5× In magnetic trip). It breaks 10 kA Icn at 230/400 V AC per EN 60898, and up to 15 kA Icu at 400–415 V AC per IEC 60947-2 — enough for most distribution subfeeds in commercial and light industrial panels. The B curve means the magnetic trip fires between 3 and 5 times the rated current (18–30 A for this 6 A unit), so it's a good fit for resistive or general-purpose loads where inrush stays low — lighting circuits, control transformers, small power supplies. Not the first choice for motor starting unless the motor's locked-rotor current is well under 30 A. Depth is 73 mm, height 81 mm. Tunnel-type terminals are straightforward for a panel wireman — strip length around 12 mm, no special lug required. ## Breaking capacity and service ratings Under IEC 60947-2 the Icu reaches 15 kA at 400–415 V AC.","metaTitle":"Schneider Electric C60H4P6AB C60H MCB, 4P, 6 A, Curve B, 10","metaDescription":"Schneider Electric C60H4P6AB miniature circuit breaker, 4P, 6 A, curve B, 10 kA breaking capacity. Multi9 range, IEC 60947-2/EN 60898. Sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"IEC 60947-2 EN 60898","Curve code":"B","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC DC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Range of product":"C60","Breaking capacity":"10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 2 N.m upside 2 N.m downside","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"6 A at 30 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"12...440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H4P6AB/miniature-circuit-breaker-c60h-4-poles-6-a-b-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H4P6AB/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of C60H4P6AB?","answer":"10 kA Icn at 230/400 V AC per EN 60898; under IEC 60947-2 the Icu reaches 15 kA at 400–415 V AC, 30 kA at 230–240 V AC, and 50 kA at 250 V DC (4P series)."},{"question":"What is the closest alternative to C60H4P6AB in the same family?","answer":"Within the Multi9 C60H series, the C60H4P6AB is the 4-pole, 6 A, B-curve variant. A direct alternative with the same pole count and rating but a different curve (C or D) would be the C60H4P6AC or C60H4P6AD — but those change the magnetic trip threshold. No pin-compatible drop-in with identical specs exists outside this order code."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H4P6AB","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H4P6AB when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}