{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60HC6RA30","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60HC6RA30","canonicalUrl":"https://aoctrl.com/schneider/C60HC6RA30","factsUrl":"https://aoctrl.com/api/mcp/products/C60HC6RA30","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric C60H RCBO, 1 pole + N, 6 A, C curve, 30 mA earth leakage, 10 kA breaking capacity, obsolete.","salesMarkdown":"The C60HC6RA30 is a C60H-series RCBO (residual current circuit breaker with overcurrent protection) from Schneider Electric, combining a 1P+N thermal-magnetic miniature circuit breaker with 30 mA earth-leakage protection in a single 35 mm DIN-rail module. Schneider Electric lists the C60HC6RA30 as obsolete. The C curve (5–10 × In magnetic trip) suits loads with moderate inrush, such as small motor starters, lighting banks, or control transformers — the breaker holds through brief startup peaks but trips fast on hard shorts. Class A earth-leakage protection (30 mA instantaneous) catches line-to-ground faults on personnel-protection circuits. Terminal capacity: up to 25 mm² rigid upstream, 16 mm² flexible downstream — enough for 6 A feeder wiring. The positive-break indication gives a visible air gap on the toggle when tripped, which helps lockout/tagout verification.","metaTitle":"C60HC6RA30 C60H RCBO, 1P+N, 6A, C Curve, 30mA, Obsolete","metaDescription":"C60HC6RA30 C60H RCBO by Schneider Electric. 1P+N, 6A, C curve, 30mA earth leakage, 10kA breaking capacity. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Standards":"IEC 1009-2-2","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3 conforming to EN 60898","Local signalling":"Positive break indication","Mounting support":"35 mm symmetrical DIN rail","Neutral position":"Right","Range of product":"C60","Breaking capacity":"10 kA Icu at 50...250 V AC 50/60 Hz conforming to IEC 1009","Device short name":"C60H RCBO","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Operating altitude":"2000 m","[In] rated current":"6 A at 30 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals (downstream) 10 mm² flexible Tunnel type terminals (downstream) 16 mm² rigid Tunnel type terminals (upstream) 16 mm² flexible Tunnel type terminals (upstream) 25 mm² rigid","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"With","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Circuit breaker application":"Distribution","Earth-leakage protection class":"Class A","[Ue] rated operational voltage":"50...250 V AC 50/60 Hz","Earth-leakage protection time delay":"Instantaneous"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/C60HC6RA30/miniature-circuit-breaker-c60h-rcbo-1-pole-+-n-6-a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60HC6RA30/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy C60HC6RA30 and how do I get a price?","answer":"The C60HC6RA30 is sourced to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time."},{"question":"What is C60HC6RA30's listed standards (IEC 1009-2-2) on this component line?","answer":"The C60HC6RA30 is designed and tested to IEC 1009-2-2, with a limitation class of 3 conforming to EN 60898."},{"question":"What is C60HC6RA30's listed curve code (C) on this component line?","answer":"The C60HC6RA30 uses a C curve, with magnetic tripping between 5 and 10 times the rated current (In)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60HC6RA30","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60HC6RA30 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}