{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60WM","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60WM","canonicalUrl":"https://aoctrl.com/schneider/C60WM","factsUrl":"https://aoctrl.com/api/mcp/products/C60WM","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NS630b-1600, MicroLogic 6.0 control unit, electronic trip, 630-1600 A at 50 °C, IEC 60947-4-2.","salesMarkdown":"## MicroLogic 6.0 control unit for ComPacT NS630b-1600 The Schneider Electric C60WM is a MicroLogic 6.0 electronic control unit for the ComPacT NS630b-1600 new generation withdrawable circuit breakers. It provides selective (S) and earth-fault (G) protection on top of the standard long-time (L) and instantaneous (I) functions — the LSI+G protection suite. Rated for trip unit currents from 630 A up to 1600 A at 50 °C, this is the brain that decides when the breaker opens and how fast. ## What the protection settings mean on the line The long-time pickup (Ir) adjusts from 0.4 to 1.0 x In across nine settings, with a thermal memory that holds the heat profile for 20 minutes — critical for motor starts where the second start sees a warmer conductor. Short-time pickup (Isd) spans 1.5 to 10 x Ir, also nine settings, with delay adjustable 0 to 0.4 s (I²t on or off). Instantaneous pickup (Ii) goes 2 to 15 x In, and can be switched Off entirely for selective coordination downstream. Ground-fault pickup (Ig) adjusts from 0.2 to 1.0 x In (for 400 A < In < 1250 A), with delay matching the short-time range. All of this means the unit can be dialed in for a specific feeder's coordination study — not just a fixed curve. This control unit is designed for the withdrawable version of the ComPacT NS630b-1600 frame. That means the breaker chassis stays wired to the bus; the cradle-mounted unit slides in and out for testing or swap without disturbing the main power connections. The protected poles config is 4t, 3t, or 3t + N/2 — covers three- and four-pole arrangements. Local signaling uses three red LEDs for electrical faults, one red for internal error, one yellow for overload. No zone-selective interlocking (ZSI) on this variant.","metaTitle":"Schneider Electric C60WM MicroLogic 6.0 Control Unit, 630-16","metaDescription":"Schneider Electric C60WM MicroLogic 6.0 control unit for ComPacT NS630b-1600. Electronic trip with LSI/G protection, 630-1600 A at 50 °C. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Range":"ComPacT","Standards":"IEC 60947-4-2","Network type":"AC","Thermal memory":"20 mn","Trip unit name":"MicroLogic 6.0","Number of poles":"3P 4P","Protection type":"L : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection G : for earth fault","lifecycle_stage":"current","Local signalling":"3 LEDs (red) for electrical fault 1 LED (red) for internal error 1 LED (yellow) for overload","Range of product":"ComPacT NS630b...1600 new generation","Trip unit rating":"630 A at 50 °C 800 A at 50 °C 1000 A at 50 °C 1250 A at 50 °C 1600 A at 50 °C","Network frequency":"50/60 Hz","Device application":"Distribution","Trip unit technology":"Electronic","Earth-leakage protection":"Without","Product or component type":"Control unit","Protected poles description":"4t 3t 3t + N/2","Circuit breaker mounting mode":"Withdrawable","Trip unit protection functions":"Selective + earth-fault protection","Zone selective interlocking ZSI":"Without","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","Long-time protection delay adjustment type tr":"Adjustable 9 settings","Short-time protection delay adjustment type tsd":"Adjustable","[Tr] Long-Time Protection Delay Adjustment Range":"0.7...16.6 s at 7.2 x Ir 0.5...24 s at 6 x Ir 12.5...600 s at 1.5 x Ir","Short-time protection pick-up adjustment type Isd":"Adjustable 9 settings","Ground-fault protection pick-up adjustment type Ig":"Adjustable 9 settings","[Ir] long-time protection pick-up adjustment range":"0.4...1 x In","[tsd] Short-time protection delay adjustment range":"0...0.4 s I²t=off 0.1...0.4 s I²t=on","Instantaneous protection pick-up adjustment type Ii":"Adjustable 9 settings","[Isd] Short-time protection pick-up adjustment range":"1.5...10 x Ir","Ground-fault protection time delay adjustment type tg":"Adjustable","[Ig] ground-fault protection pick-up adjustment range":"0.2...1 x In for 400 A < In < 1250 A 0.3...1 x In for In 500...1200 A for In >= 1250 A","[Ii] instantaneous protection pick-up adjustment range":"2...15 x In Off","[Tg] Ground-Fault Protection Time Delay Adjustment Range":"0...0.4 s I²t=off 0.1...0.4 s I²t=on","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$4,209.84","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e1e8492ae282a7adc3d47178d59094f5.pdf","sourceUrl":"https://www.se.com/id/en/product/C60WM/control-unit-micrologic-6-0-compact-ns630b-to-ns1600-withdrawable-manually-operated-selective-and-earthfault-protections/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60WM/alternatives.json"},"ai":{"faq":[{"question":"What is C60WM's listed range and standards?","answer":"The C60WM belongs to the ComPacT NS630b-1600 new generation range and is designed to IEC 60947-4-2, the standard for contactors and motor-starters with integral overload protection."},{"question":"What protection functions does the MicroLogic 6.0 control unit provide?","answer":"The MicroLogic 6.0 provides long-time (L) overload, short-time (S) selective short-circuit, instantaneous (I) short-circuit, and ground-fault (G) earth-leakage protection — the LSI+G suite. All pickup and delay settings are field-adjustable."},{"question":"Where can I buy the C60WM and what is the lead time?","answer":"The C60WM is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60WM","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60WM when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}