{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C6347E570","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C6347E570","canonicalUrl":"https://aoctrl.com/schneider/C6347E570","factsUrl":"https://aoctrl.com/api/mcp/products/C6347E570","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX400...630, MicroLogic 7.3 E electronic trip unit, 570 A at 40 °C, 4P, LSIR protection, LCD display, EN/IEC 60947-2.","salesMarkdown":"## MicroLogic 7.3 E Trip Unit for ComPacT NSX — 570 A, LSIR Protection The Schneider Electric C6347E570 is a MicroLogic 7.3 E electronic trip unit for the ComPacT NSX400...630 range, rated 570 A at 40 °C. It provides LSIR protection — long-time (L), short-time (S), instantaneous (I), and earth-leakage (R) — meeting EN/IEC 60947-2 for distribution applications. The 4-pole unit includes an integrated earth-leakage protection (Class A) and an LCD display for metering and event logs. A 20-minute thermal memory before and after tripping ensures coordination on reclose cycles, critical for keeping a weld line or conveyor string running without nuisance trips. ## Protection Functions and Adjustability Long-time pick-up (Ir) adjusts from 250 to 570 A, with delay tr settable 15–400 s at 1.5×Ir, 0.35–11 s at 7.2×Ir, or 0.5–16 s at 6×Ir. Short-time pick-up (Isd) is adjustable, with delay tsd from 0 to 0.4 s (I²t off) or 0.1 to 0.4 s (I²t on). Instantaneous protection (Ii) is also adjustable. Earth-leakage can be disabled via the IΔn rotary switch. Neutral protection offers four configurations: 3D + N/2, 4D, 3D + OSN, or no protection. ## Communication, Metering, and Signalling The trip unit reports protection and alarm settings, energy metering, demand current and power, power quality, earth-leakage current, time-stamped histories and event tables, instantaneous and demand values, maximeters/minimeters, maintenance indicators, and test reports. Local signalling includes a flashing green LED for ready-to-operate, a red LED at 105% Ir for overload, and an orange LED at 90% Ir for pre-alarm. The LCD display supports on-device interrogation of all these metrics. ## Environmental and Installation Ratings IP40 front-of-panel protection (IEC 60529) keeps out tools and dust. The unit is Class II electrically (double-insulated), fixed-mount, with neutral on the left. No zone selective interlocking (ZSI) is provided.","metaTitle":"Schneider Electric C6347E570 ComPacT NSX MicroLogic 7.3 E Tr","metaDescription":"Schneider Electric C6347E570 MicroLogic 7.3 E electronic trip unit for ComPacT NSX400-630. 570 A at 40 °C, LSIR protection, LCD display, EN/IEC 60947-2. Current lifecycle stage, av","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Range":"ComPacT","title":"C6347E570","Standards":"EN/IEC 60947-2","description":"Trip unit MicroLogic Vigi 7.3E, ComPacT NSX630, 4 poles, basic and earth leakage protections, energy meter, 570A rating","Display type":"LCD display","Network type":"AC","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 7.3 E","Protection type":"L : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection R : for earth-leakage protection","lifecycle_stage":"current","Local signalling":"Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload","Neutral position":"Left","Pollution degree":"3 conforming to IEC 60947-1","Range of product":"ComPacT NSX400...630","Trip unit rating":"570 A at 40 °C","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","Type of measurement":"Energy meter","Trip unit technology":"Electronic","Communication of data":"Protection and alarm settings Energy metering Demand current and power Power quality Earth leakage current Time-stamped histories and event tables Instantaneous and demand values Maximeters/minimeters Maintenance indicators Test reports","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Integrated","Product or component type":"Trip unit","Neutral protection settings":"0.5 x Ir (3D + N/2) 1 x Ir (4D) 1.6 x Ir (3D + OSN) No protection (3D)","Protected poles description":"3D + N/2 4D 3D + OSN 3D","Circuit breaker mounting mode":"Fixed","Earth-leakage protection class":"Class A","Trip unit protection functions":"LSIR","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Zone selective interlocking ZSI":"Without","Electrical shock protection class":"Class II","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","Earth-leakage protection specific mode":"OFF using the IΔn rotary switch","Long-time protection delay adjustment type tr":"Adjustable","Short-time protection delay adjustment type tsd":"Adjustable","[Tr] Long-Time Protection Delay Adjustment Range":"15...400 s at 1.5 x Ir 0.35...11 s at 7.2 x Ir 0.5...16 s at 6 x Ir","Short-time protection pick-up adjustment type Isd":"Adjustable","[Ir] long-time protection pick-up adjustment range":"250...570 A","[tsd] Short-time protection delay adjustment range":"0...0.4 s I²t=off 0.1...0.4 s I²t=on","Instantaneous protection pick-up adjustment type Ii":"Adjustable","[Isd] Short-time protection pick-up adjustment range":"1.5...10 x Ir","[Ii] instantaneous protection pick-up adjustment range":"1.5...11 x In","Earth-leakage protection sensitity adjustment type IΔn":"Adjustable","Earth-leakage protection time delay adjustement type Δt":"Adjustable","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings","[Δt] Earth-leakage protection time delay adjustment range":"0 ms 60 ms 150 ms 500 ms 1 s","[IΔn] earth-leakage protection sensitivity adjustment range":"0.3 A 0.5 A 1 A 3 A 5 A 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$24.40","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1169a3bc3906339382bf0025d50b8173.pdf","sourceUrl":"https://www.se.com/ph/en/product/C6347E570/trip-unit-micrologic-vigi-7-3e-compact-nsx630-4-poles-basic-and-earth-leakage-protections-energy-meter-570a-rating/"},"ai":{"faq":[{"question":"Where can I buy C6347E570 and how do I get a price?","answer":"The C6347E570 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is C6347E570's listed range and standards compliance?","answer":"The C6347E570 belongs to the Schneider Electric ComPacT NSX400...630 range and complies with EN/IEC 60947-2 for circuit-breaker and trip-unit coordination."},{"question":"What protection functions does the MicroLogic 7.3 E provide?","answer":"The MicroLogic 7.3 E provides LSIR protection: L for overload (long-time), S for short-time short-circuit, I for instantaneous short-circuit, and R for earth-leakage protection. All four are adjustable."},{"question":"What compliance documentation does Schneider provide for C6347E570?","answer":"The unit is designed to EN/IEC 60947-2, carries IP40 (IEC 60529), Pollution Degree 3 (IEC 60947-1), and Class II electrical shock protection. Specific RoHS, REACH, and UL documentation should be confirmed from the manufacturer's compliance portal for the exact date code."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C6347E570","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C6347E570 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}