{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C63F44V570","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C63F44V570","canonicalUrl":"https://aoctrl.com/schneider/C63F44V570","factsUrl":"https://aoctrl.com/api/mcp/products/C63F44V570","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX630F, MCCB, 570 A, 4P, MicroLogic 4.3 electronic trip unit, 36 kA at 415 V AC, EN/IEC 60947-2.","salesMarkdown":"## Integrator note — ComPacT NSX630F, 570 A, 4P The C63F44V570 is a Schneider Electric ComPacT NSX630F moulded-case circuit breaker with a 570 A electronic trip unit (MicroLogic 4.3) at 40 °C, four poles, and an F breaking-capacity code — 36 kA Icu at 415 V AC per IEC 60947-2. ## Breaking capacity — what the F code means The F breaking-capacity code gives 36 kA Icu at 380/415 V AC and 40 kA at 220/240 V AC. At 440 V it drops to 30 kA; at 525 V to 20 kA; at 690 V to 10 kA. That's the full interrupting rating per IEC 60947-2 — the breaker can clear a fault at those levels and still be reclosed. For UL 60947-4-1 applications (motor-circuit protectors), the same breaker carries 85 kA Icu at 240 V AC, 35 kA at 480 V, and 20 kA at 600 V. If your panel is UL-listed, use those numbers for the SCCR calculation. Backplate-mounted, flat on the back, horizontal or vertical orientation. The 4-pole unit is 185 mm wide, 255 mm high, 110 mm deep — fits a standard distribution panel footprint. Front connections top and bottom; neutral on the left. Overvoltage category IV — suitable for main incoming supply. Ambient humidity 0–95 % non-condensing; altitude up to 2000 m without derating, 2000–5000 m with derating.","metaTitle":"Schneider Electric C63F44V570 ComPacT NSX630F MCCB, 570 A, 4","metaDescription":"Schneider Electric C63F44V570 ComPacT NSX630F MCCB, 570 A rated at 40 °C, 4 poles, MicroLogic 4.3 electronic trip unit, 36 kA at 415 V AC. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"110 mm","Width":"185 mm","Height":"255 mm","Voltage":"440 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"45 mm","Trip Unit Type":"Electronic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Insulation Voltage Ui":"500 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"8000 cycles at 440 V In/2 4000 cycles at 440 V In 6000 cycles at 690 V In/2 2000 cycles at 690 V In","Mechanical Life Cycles":"15000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Earth leakage circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$2,486.39 – $5,951.34","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/453988e0d9b875377b986cc36d7ec09b.pdf","sourceUrl":"https://www.se.com/id/en/product/C63F44V570/circuit-breaker-compact-nsx630f-36ka-at-415vac-micrologic-4-3-vigi-trip-unit-570a-4-poles-4d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C63F44V570/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C63F44V570","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C63F44V570 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}