{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C63H31M500","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C63H31M500","canonicalUrl":"https://aoctrl.com/schneider/C63H31M500","factsUrl":"https://aoctrl.com/api/mcp/products/C63H31M500","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, NSX630H, 3-pole, 500 A, electronic MicroLogic 1.3 M trip unit, 70 kA at 415 V AC, motor protection.","salesMarkdown":"The C63H31M500 is a Schneider Electric ComPacT NSX630H molded-case circuit breaker (MCCB) with a 500 A electronic MicroLogic 1.3 M trip unit, designed specifically for motor protection in three-phase AC networks. It's a 3-pole unit rated for 500 A at 65 °C, meaning it's sized for a motor load drawing that full current continuously in a warm panel — no derating guesswork at standard ambient. The MicroLogic 1.3 M trip unit is electronic, not thermal-magnetic. That matters for motor starting — it gives you adjustable short-time and instantaneous protection (S and I curves per the spec), so you can set the trip point above the inrush without losing coordination downstream. Category A utilization means it's not intended for current-limiting duty; it's a standard-break device for distribution and motor circuits. Front connections top and bottom, with a 45 mm connection pitch, so busbar or cable lugs land cleanly on the line and load side. IP40 front face keeps accidental tool contact out; IK07 impact rating means it survives a knock during panel assembly. The interrupting rating varies with system voltage, which is typical for an MCCB. At 240 V AC it's 100 kA Icu; at 415 V AC it's 70 kA; at 440 V AC it's 65 kA; at 500 V AC it's 50 kA; at 525 V AC it's 35 kA; and at 690 V AC it's 20 kA — all per IEC 60947-2. For UL 60947-4-1 applications, it's rated 85 kA at 240 V AC, 65 kA at 480 V AC, and 20 kA at 600 V AC. That's a wide voltage range, so it fits 400 V class and 480 V class systems without needing a different frame. ## Durability and environmental limits Mechanical durability is 15,000 cycles; electrical durability depends on the load — 8,000 cycles at 440 V at half-rated current, 4,000 cycles at full rated current, and 2,000 cycles at 690 V at full current. That's solid for a motor-protection breaker in a machine that cycles a few times per shift.","metaTitle":"C63H31M500 ComPacT NSX 630H 3P 500A MicroLogic 1.3 M MCCB","metaDescription":"Schneider Electric C63H31M500 ComPacT NSX630H MCCB, 500 A, 70 kA at 415 V AC, MicroLogic 1.3 M electronic trip unit for motor protection. Current lifecycle stage. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"110 mm","Width":"140 mm","Height":"255 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP40","Application":"Motor protection","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"45 mm","Trip Unit Type":"Electronic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 65 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 20 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1","Insulation Voltage Ui":"800 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"8000 cycles at 440 V In/2 4000 cycles at 440 V In 6000 cycles at 690 V In/2 2000 cycles at 690 V In","Mechanical Life Cycles":"15000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,206.01","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5d6e7444e396fe38c080e0cd3a2f3e3d.pdf","sourceUrl":"https://www.se.com/sg/en/product/C63H31M500/circuit-breaker-compact-nsx630h-70ka-415vac-3-poles-micrologic-1-3m-trip-unit-500a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C63H31M500/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C63H31M500","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C63H31M500 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}