{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C63N47E570","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C63N47E570","canonicalUrl":"https://aoctrl.com/schneider/C63N47E570","factsUrl":"https://aoctrl.com/api/mcp/products/C63N47E570","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX C63N47E570 molded case circuit breaker, 4 poles, 570 A switching current, 570 A trip unit rating at 40 °C, 85 kA Icu at 440 V AC, MicroLogic 7.3 E electronic trip unit with L,S,I,R protection, fixed mounting, 45 mm terminal pitch, EN/IEC 60947-2.","salesMarkdown":"## Overview The C63N47E570 is a Schneider ComPacT NSX molded case circuit breaker rated for 570 A switching current on a 440 V AC, 60 Hz network, with a 4-pole configuration and an 85 kA Icu breaking capacity. It carries a MicroLogic 7.3 E electronic trip unit providing L (overload), S (short-time short-circuit), I (instantaneous short-circuit), and R (earth-leakage) protection, plus integrated energy metering with time-stamped event logs. Compared to the C63N3, the C63N47E570 adds a fourth pole (4 vs 3) and drops the switching current from 630 A to 570 A, while the C63N3 is a basic frame without earth-leakage protection. Choose the C63N47E570 when a 4-pole, earth-leakage-protected breaker is required; the C63N3 suits 3-pole distribution without ground-fault sensing.","metaTitle":"Schneider C63N47E570 ComPacT NSX MCCB, 4-pole, 570 A, 85 kA Icu","metaDescription":"Schneider C63N47E570 ComPacT NSX molded case circuit breaker: 4 poles, 570 A switching current, 85 kA Icu at 440 V AC, MicroLogic 7.3 E trip unit with L,S,I,R protection, energy me","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"110 mm","Width":"185 mm","Height":"255 mm","Voltage":"440 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Toggle","Display Type":"LCD display","Product Status":"Active","Terminal Pitch":"45 mm","Trip Unit Type":"Electronic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Breaking Capacity":"85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 50 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 20 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1","Insulation Voltage Ui":"500 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"8000 cycles at 440 V In/2 4000 cycles at 440 V In 6000 cycles at 690 V In/2 2000 cycles at 690 V In","Mechanical Life Cycles":"15000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Earth leakage circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$3,207.93","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/47ffbc5e1f53d587a1eda204db974cba.pdf","sourceUrl":"https://www.se.com/hk/en/product/C63N47E570/circuit-breaker-compact-nsx630n-50ka-415vac-4-poles-micrologic-vigi-7-3e-trip-unit-570a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C63N47E570/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C63N47E570","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C63N47E570 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}