{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CAD32ABD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CAD32ABD","canonicalUrl":"https://aoctrl.com/schneider/CAD32ABD","factsUrl":"https://aoctrl.com/api/mcp/products/CAD32ABD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca control relay, CAD32ABD, 3NO+2NC, ≤690V, 24V DC standard coil, snap-in terminals.","salesMarkdown":"## Control relay for control-circuit switching The CAD32ABD is a TeSys Deca control relay from Schneider Electric, configured with 3 normally-open and 2 normally-closed contacts. It is designed for control-circuit duty in industrial panels, switching loads per utilisation categories AC-15, AC-14, and DC-13. The 24 V DC standard coil operates within the rated voltage range, and the snap-in terminals mount directly onto a DIN rail — no tools required for installation or removal. The AC-15 and DC-13 utilisation categories per EN/IEC 60947-5-1 define this relay for switching electromagnetic loads — contactors, solenoid valves, and small motor starters — where inrush currents can exceed steady-state. AC-14 covers switching of loads with moderate inrush, such as pilot lamps and resistive loads. The 3 NO + 2 NC contact arrangement gives you three independent make circuits and two break circuits, which suits interlocking or dual-channel safety circuits where you need both a positive-opening NC and a separate NO for feedback. The operating temperature range spans -40 to 140 °F (-40 to 60 °C), with derating permitted up to 158 °F (70 °C). The IP2X front-face protection per VDE 0106 means the relay's live parts are protected against finger contact from the front — standard for enclosed panel-mount gear. Altitude rating to 9842.52 ft (3000 m) without derating covers installations in high-altitude facilities, such as mining or mountain-based processing plants. The TH protective treatment per IEC 60068 indicates the relay is treated for tropical humid conditions — relevant for coastal or unconditioned environments.","metaTitle":"Schneider Electric CAD32ABD TeSys Deca Control Relay, 3NO+2N","metaDescription":"Active control relay, TeSys Deca series, 3NO+2NC contacts, 24V DC coil, rated to 690V. Complies with EN/IEC 60947-5-1, UL 60947-5-1, CSA. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"3.7 in (93 mm)","Range":"TeSys","Width":"1.8 in (45 mm)","title":"CAD32ABD","Height":"4.2 in (107 mm)","Category":"US10I1222371","Standards":"EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1","description":"Control relay, TeSys Deca, 3NO+2NC, <=690V, 24V DC standard coil, snap-in terminals","Product name":"TeSys CAD","lifecycle_stage":"current","Device short name":"CAD","Operating altitude":"0...9842.52 ft (0...3000 m)","Protective treatment":"TH IEC 60068","Utilisation category":"AC-15 AC-14 DC-13","Contactor application":"Control circuit","Mechanical robustness":"Shocks control relay open10 Gn for 11 ms IEC 60068-2-27 Shocks control relay closed15 Gn for 11 ms IEC 60068-2-27 Vibrations control relay open2 Gn, 5...300 Hz IEC 60068-2-6 Vibrations control relay closed4 Gn, 5...300 Hz IEC 60068-2-6","Nbr. of units in pkg.":"1","IP degree of protection":"IP2X front face VDE 0106","Pole contact composition":"3 NO + 2 NC","Product or Component Type":"Control relay","[Ue] rated operational voltage":"10 MOhm","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient air temperature for operation":"-40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$147.74","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cb3a26df5ed513bd0332104f74ccf5f0.pdf","sourceUrl":"https://www.se.com/hk/en/product/CAD32ABD/control-relay-tesys-deca-3no+2nc-690v-24v-dc-standard-coil-snapin-terminals/"},"ai":{"faq":[{"question":"What standards does the CAD32ABD comply with?","answer":"It complies with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1."},{"question":"What is the contact configuration of the CAD32ABD?","answer":"The CAD32ABD has 3 normally-open and 2 normally-closed contacts (3 NO + 2 NC)."},{"question":"What is the operating temperature range for the CAD32ABD?","answer":"The ambient air temperature for operation is -40 to 140 °F (-40 to 60 °C), with derating permitted up to 158 °F (70 °C)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CAD32ABD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CAD32ABD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}