{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CAD32AMD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CAD32AMD","canonicalUrl":"https://aoctrl.com/schneider/CAD32AMD","factsUrl":"https://aoctrl.com/api/mcp/products/CAD32AMD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca control relay, CAD32AMD, 3NO+2NC, ≤690V, 220V DC standard coil, snap-in terminals.","salesMarkdown":"Its 3 NO + 2 NC pole configuration gives you three normally-open and two normally-closed contact sets in one 45 mm wide package, sized for a 107 mm height and 93 mm depth on the DIN rail. Rated for utilisation categories AC-15, AC-14, and DC-13, this relay is designed to switch electromagnetic loads like contactor coils, solenoid valves, and small DC motors — the AC-15 rating specifically covers switching of electromagnetic loads above 72 VA, which is the typical control transformer or contactor coil pull-in current. The DC-13 rating handles solenoids and DC electromagnets, so it's suited for DC control circuits common in process lines. The 220 V DC standard coil means it pulls in reliably on a 220 VDC control supply, and the snap-in terminals speed up panel wiring — no screwdriver needed for the coil or contact terminations. ## Where you'll find it in a panel This relay lives on a DIN rail inside a control cabinet, typically as an interposing relay between a PLC output card and a contactor coil or valve manifold. The IP2X front-face protection (per VDE 0106) means the front of the relay is finger-safe when mounted in an enclosure — no additional cover needed on the front face, though the rear terminals are live. Storage range of -60 to 80 °C handles shipping and idle spares. Altitude rating to 3000 m means it's fine for most installations outside high-mountain or unpressurised aircraft applications. The CAD32AMD carries EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. IEC 60947-5-1 is the standard for control circuit devices and switching elements — it covers the relay's rated operational voltage, making and breaking capacity, and endurance. UL and CSA marks mean the relay is accepted for North American panels without additional evaluation. GB/T and JIS marks cover Chinese and Japanese installations respectively. The protective treatment 'TH' per IEC 60068 means the relay is treated for tropical environments — humidity and fungal growth resistance, relevant if the panel sits in a non-air-conditioned space in a warm climate.","metaTitle":"Schneider Electric CAD32AMD TeSys Deca Control Relay, 3NO+2N","metaDescription":"Active TeSys Deca control relay CAD32AMD with 3NO+2NC contacts, 220V DC coil, rated for AC-15/DC-13 control circuits. Complies with EN/IEC 60947-5-1, UL, CSA. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"93 mm","Range":"TeSys","Width":"45 mm","title":"CAD32AMD","Height":"107 mm","Standards":"EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1","description":"Control relay, TeSys Deca, 3NO+2NC, <=690V, 220V DC standard coil, snap-in terminals","Product name":"TeSys CAD","lifecycle_stage":"current","Device short name":"CAD","Operating altitude":"0...3000 m","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-15 AC-14 DC-13","Contactor application":"Control circuit","Mechanical robustness":"Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP2X front face conforming to VDE 0106","Pole contact composition":"3 NO + 2 NC","Product or component type":"Control relay","[Ue] rated operational voltage":"10 MOhm","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/946e2f6df7773c7e046b67e5482010dd.pdf","sourceUrl":"https://www.se.com/ie/en/product/CAD32AMD/control-relay-tesys-deca-3no+2nc-690v-220v-dc-standard-coil-snapin-terminals/"},"ai":{"faq":[{"question":"What are the key ratings I need to check for fit?","answer":"The key ratings are the 3 NO + 2 NC contact configuration, the 220 V DC coil voltage, and the utilisation categories AC-15, AC-14, and DC-13. The AC-15 rating means it's rated for switching electromagnetic loads above 72 VA, typical for contactor coils. The DC-13 rating covers DC solenoid and electromagnet loads. Physical dimensions are 107 mm height, 45 mm width, and 93 mm depth."},{"question":"What compliance documentation does Schneider provide for the CAD32AMD?","answer":"The CAD32AMD complies with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. It also carries protective treatment TH per IEC 60068 for tropical environments."},{"question":"What is the closest alternative to the CAD32AMD in the TeSys Deca family?","answer":"Within the TeSys Deca range, the closest alternative would be a relay with the same 3 NO + 2 NC contact configuration but a different coil voltage — for example, a 24 V DC or 110 V DC coil variant. The physical footprint and contact ratings are identical; only the coil voltage changes. For a direct pin-compatible swap, match the coil voltage to your control supply."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CAD32AMD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CAD32AMD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}