{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CAD32AS7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CAD32AS7","canonicalUrl":"https://aoctrl.com/schneider/CAD32AS7","factsUrl":"https://aoctrl.com/api/mcp/products/CAD32AS7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca control relay, CAD32AS7, 3NO+2NC, ≤690V, 500V AC standard coil, snap-in terminals.","salesMarkdown":"The CAD32AS7 is a TeSys Deca control relay from Schneider Electric's TeSys range, configured with 3 normally-open and 2 normally-closed contacts. It's designed for control-circuit switching in industrial panels, rated for operational voltages up to 690 V and carrying utilisation categories AC-15, AC-14, and DC-13 — meaning it handles solenoid and electromagnetic loads in AC control circuits, and DC inductive loads like contactor coils. The 500 V AC standard coil is built into the snap-in terminal base. The DC-13 rating covers DC inductive loads, which is relevant when the relay is switching DC contactor coils or brake solenoids in a panel. The 3NO+2NC contact arrangement gives you three independent make contacts for pilot devices or PLC inputs, plus two break contacts for safety interlocks or status feedback. Mechanical robustness is specified: the relay withstands 10 Gn shocks for 11 ms in the open position and 15 Gn when closed, with vibration resistance of 2 Gn (open) and 4 Gn (closed) across 5–300 Hz. That's enough for installation on machinery with moderate vibration — conveyors, pumps, compressors — without nuisance dropout. The IP2X front-face protection means finger-safe to VDE 0106, which is standard for enclosed panel mounting. Operating temperature spans -40 to 60 °C, with derating required above 60 °C up to 70 °C. Storage range is -60 to 80 °C. Altitude rating goes to 3000 m without derating. The TH protective treatment per IEC 60068 means the relay is treated against tropical humidity — suitable for non-condensing environments in most industrial settings. The snap-in terminals accept the coil and contact wiring; no separate base is needed. Mount it alongside contactors in a motor control centre or as an interposing relay between a PLC output card and higher-current loads.","metaTitle":"Schneider CAD32AS7 TeSys Deca Control Relay, 3NO+2NC, ≤690V","metaDescription":"Active-production control relay from TeSys Deca series. 3NO+2NC contacts, AC-15/DC-13 rated, ≤690V. UL/CSA/IEC compliant. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"93 mm","Range":"TeSys","Width":"45 mm","Height":"107 mm","Standards":"EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1","Product name":"TeSys CAD","lifecycle_stage":"current","Device short name":"CAD","Operating altitude":"0...3000 m","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-15 AC-14 DC-13","Contactor application":"Control circuit","Mechanical robustness":"Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP2X front face conforming to VDE 0106","Pole contact composition":"3 NO + 2 NC","Product or component type":"Control relay","[Ue] rated operational voltage":"10 MOhm","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/CAD32AS7/control-relay-tesys-deca-3no+2nc-690v-500v-ac-standard-coil-snapin-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/CAD32AS7/alternatives.json"},"ai":{"faq":[{"question":"What utilisation categories does CAD32AS7 carry?","answer":"It is rated for AC-15, AC-14, and DC-13. AC-15 covers switching electromagnetic loads (contactors, solenoids) in AC control circuits; DC-13 covers DC inductive loads like DC contactor coils."},{"question":"What compliance standards does CAD32AS7 meet?","answer":"It complies with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. The TH protective treatment conforms to IEC 60068 for tropical environments."},{"question":"What is the contact configuration?","answer":"3 normally-open and 2 normally-closed poles. That gives three make contacts for pilot/control signals and two break contacts for safety or status feedback."},{"question":"What are the mounting dimensions?","answer":"Width 45 mm, height 107 mm, depth 93 mm. It snaps onto standard DIN rail. The IP2X front face is finger-safe per VDE 0106."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CAD32AS7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CAD32AS7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}