{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CAD32AV7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CAD32AV7","canonicalUrl":"https://aoctrl.com/schneider/CAD32AV7","factsUrl":"https://aoctrl.com/api/mcp/products/CAD32AV7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca control relay, CAD32AV7, 3NO+2NC, ≤690V, 400V AC standard coil, snap-in terminals.","salesMarkdown":"The Schneider Electric CAD32AV7 is a TeSys Deca control relay with a 3 NO + 2 NC pole contact composition, rated for operational voltages up to 690 V and fitted with a 400 V AC standard coil. It's designed for control circuit applications — the kind of relay that sits between a PLC output and a motor contactor coil, or that extends the auxiliary contact count on a larger starter assembly. The utilisation categories — AC-15, AC-14, and DC-13 — tell you exactly what loads this relay can switch. AC-15 covers solenoid valves and electromagnetic clutches (inductive loads above 72 VA); AC-14 covers smaller contactor coils and relays (inductive loads below 72 VA); DC-13 covers solenoids and contactors in DC control circuits. So this relay is not a general-purpose signal relay — it's built for the inrush and break currents that control-circuit inductive loads demand. The 3 NO + 2 NC contact arrangement gives you flexibility: three normally-open for switching loads on, two normally-closed for status feedback or interlock circuits. The IP2X front-face protection (conforming to VDE 0106) means it's finger-safe from the front once installed, which is the minimum for a panel with live exposed terminals. Operating temperature range is -40 to 60 °C, with derating allowed up to 70 °C, and storage from -60 to 80 °C — so it handles unheated warehouses and plant-floor heat alike. The relay carries approvals under EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. That covers the main global regulatory jurisdictions — IEC for Europe and much of Asia, UL/CSA for North America, GB/T for China, JIS for Japan. If you're shipping panels to multiple regions, this single part number satisfies the certification requirements without needing region-specific variants. The mechanical robustness ratings — 10 Gn shocks for 11 ms when open, 15 Gn when closed, and vibration tolerance up to 4 Gn at 5-300 Hz when closed — mean it holds its state under the kind of vibration you'd see near a large motor or on a machine baseplate.","metaTitle":"Schneider Electric CAD32AV7 TeSys Deca Control Relay, 3NO+2N","metaDescription":"Schneider Electric CAD32AV7 TeSys Deca control relay, 3NO+2NC, ≤690V, 400V AC coil. Active production. Sourced to order. Cite EN/IEC 60947-5-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"93 mm","Range":"TeSys","Width":"45 mm","title":"CAD32AV7","Height":"107 mm","Standards":"EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1","description":"Control relay, TeSys Deca, 3NO+2NC, <=690V, 400V AC standard coil, snap-in terminals","Product name":"TeSys CAD","lifecycle_stage":"current","Device short name":"CAD","Operating altitude":"0...3000 m","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-15 AC-14 DC-13","Contactor application":"Control circuit","Mechanical robustness":"Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP2X front face conforming to VDE 0106","Pole contact composition":"3 NO + 2 NC","Product or component type":"Control relay","[Ue] rated operational voltage":"10 MOhm","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/048acd40c55398f09d1cb42cea380656.pdf","sourceUrl":"https://www.se.com/uk/en/product/CAD32AV7/control-relay-tesys-deca-3no+2nc-690v-400v-ac-standard-coil-snapin-terminals/"},"ai":{"faq":[{"question":"What is the closest alternative to the CAD32AV7 in the TeSys family?","answer":"Within the TeSys Deca range, the closest alternative would be a relay with the same 3 NO + 2 NC contact configuration but a different coil voltage — for example, a 230 V AC coil variant if your control voltage differs. The mechanical footprint and terminal layout are identical across the Deca series, so swapping coil voltage doesn't change the mounting or wiring."},{"question":"What compliance documentation does Schneider provide for the CAD32AV7?","answer":"The relay is certified to EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. Schneider typically provides a Declaration of Conformity covering these standards, plus the standard EU Declaration of Conformity for the Low Voltage Directive."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CAD32AV7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CAD32AV7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}