{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CAD32AW7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CAD32AW7","canonicalUrl":"https://aoctrl.com/schneider/CAD32AW7","factsUrl":"https://aoctrl.com/api/mcp/products/CAD32AW7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca control relay, CAD32AW7, 3NO+2NC, ≤690V, 277V AC standard coil, snap-in terminals.","salesMarkdown":"The CAD32AW7 is a TeSys Deca control relay from Schneider Electric, built for switching control circuits in industrial panels. It carries 3 normally-open and 2 normally-closed contacts, rated for operational voltages up to 690 V with a 277 V AC standard coil. The snap-in terminals cut wiring time on the rail — no screwdriver needed for the coil or contact connections. Rated for utilisation categories AC-15, AC-14, and DC-13 per EN/IEC 60947-5-1, so it handles solenoid loads, electromagnetic clutches, and DC relay coils without derating surprises. The IP2X front face keeps fingers off live terminals inside the panel. Dimensions are 45 mm wide, 107 mm tall, 93 mm deep — a standard 45 mm modular width that clips onto DIN rail and leaves room for adjacent contactors or overloads in a motor starter row. Operating temperature range is -40 to 60 °C, with derating above 60 °C up to 70 °C; storage tolerance goes from -60 to 80 °C. Good for unheated enclosures in temperate climates. Mechanical robustness specs: the relay stays closed through 15 Gn shocks and open through 10 Gn shocks (11 ms pulses), and handles vibration up to 4 Gn closed, 2 Gn open, across 5–300 Hz. That covers most conveyor-line and compressor-adjacent mounting without extra damping. Compliant with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. Protective treatment is TH conforming to IEC 60068, meaning it's tropicalised for humid environments. Operating altitude is rated up to 3000 m — no derating needed for most high-altitude plants.","metaTitle":"Schneider TeSys CAD32AW7 Control Relay, 3NO+2NC, 690V","metaDescription":"Active TeSys Deca control relay CAD32AW7, 3NO+2NC contacts, rated ≤690V with 277V AC coil. Snap-in terminals, IP2X front face. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"93 mm","Range":"TeSys","Width":"45 mm","Height":"107 mm","Standards":"EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1","Product name":"TeSys CAD","lifecycle_stage":"current","Device short name":"CAD","Operating altitude":"0...3000 m","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-15 AC-14 DC-13","Contactor application":"Control circuit","Mechanical robustness":"Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP2X front face conforming to VDE 0106","Pole contact composition":"3 NO + 2 NC","Product or component type":"Control relay","[Ue] rated operational voltage":"10 MOhm","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/CAD32AW7/control-relay-tesys-deca-3no+2nc-690v-277v-ac-standard-coil-snapin-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/CAD32AW7/alternatives.json"},"ai":{"faq":[{"question":"What utilisation categories does CAD32AW7 cover?","answer":"It is rated for AC-15, AC-14, and DC-13 per IEC 60947-5-1. AC-15 covers solenoid loads above 72 VA, AC-14 covers electromagnetic loads below 72 VA, and DC-13 covers DC solenoids and clutches."},{"question":"What is the contact configuration on CAD32AW7?","answer":"3 normally-open and 2 normally-closed poles. That gives you three form A and two form B contacts in a single 45 mm package."},{"question":"What standards does CAD32AW7 comply with?","answer":"EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. Also carries TH protective treatment per IEC 60068 for humid environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CAD32AW7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CAD32AW7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}