{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CAD32ML","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CAD32ML","canonicalUrl":"https://aoctrl.com/schneider/CAD32ML","factsUrl":"https://aoctrl.com/api/mcp/products/CAD32ML","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca CAD32ML control relay, 3NO+2NC, ≤690V, 220V DC low consumption coil, screw clamp terminals.","salesMarkdown":"The 220 V DC low-consumption coil is the defining selection parameter here — it draws less inrush than an equivalently rated AC coil, which matters when the control transformer or DC supply is already loaded near its limit. Screw-clamp terminals on the contact block keep wiring straightforward for panel builders. This relay carries utilisation categories AC-15, AC-14, and DC-13 per IEC 60947-5-1. AC-15 covers solenoid-valve and electromagnetic-brake loads above 72 VA; AC-14 covers smaller solenoid loads below 72 VA. DC-13 is the inductive DC load category — solenoids, contactor coils — so if you are switching a DC coil bank or a valve manifold, this is the rating that governs contact life. The relay is also certified to UL 60947-5-1 and CSA C22.2 No 60947-5-1, so it passes North American panel inspections without a separate UL marking exercise. The CAD32ML occupies a 45 mm wide footprint on the DIN rail — three modules wide in a typical 18 mm-per-module panel layout. Depth is 93 mm from the DIN rail back to the furthest terminal point, so it clears a 100 mm deep enclosure without forcing a deeper gland plate. Storage range extends to -60 to 80 °C, which is the handling and shipping limit, not the running limit. Operating altitude is rated to 3000 m; above that, air density affects dielectric withstand and cooling, so the relay should be derated per IEC 60947-1. IP2X finger protection per VDE 0106 means the live parts are guarded against accidental contact but the relay is not sealed — it belongs in a clean, dry enclosure, not a washdown zone. Protective treatment is TH per IEC 60068, which is a tropical-heat classification: the relay is treated against humidity and fungal growth, so it holds up in non-condensing environments up to 95% RH.","metaTitle":"Schneider TeSys CAD32ML Control Relay, 3NO+2NC, 220V DC","metaDescription":"TeSys Deca control relay CAD32ML, 3NO+2NC contacts, 220V DC low consumption coil, screw clamp terminals. Active production. UL/CSA/IEC certified.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"3.7 in (93 mm)","Range":"TeSys","Width":"1.8 in (45 mm)","title":"CAD32ML","Height":"3.03 in (77 mm)","Standards":"EN/IEC 60947-5-1 GB/T 14048.5 UL 60947-5-1 CSA C22.2 No 60947-5-1 JIS C8201-5-1","description":"Control relay, TeSys Deca, 3NO+2NC, <=690V, 220V DC low consumption coil, screw clamp terminals","Product name":"TeSys CAD","lifecycle_stage":"current","Device short name":"CAD","Operating altitude":"0...3000 m","Protective treatment":"TH IEC 60068","Utilisation category":"DC-13 AC-15 AC-14","Contactor application":"Control circuit","Mechanical robustness":"Shocks control relay open10 Gn for 11 ms IEC 60068-2-27 Shocks control relay closed15 Gn for 11 ms IEC 60068-2-27 Vibrations control relay open2 Gn, 5...300 Hz IEC 60068-2-6 Vibrations control relay closed4 Gn, 5...300 Hz IEC 60068-2-6","IP degree of protection":"IP2X VDE 0106","Pole contact composition":"3 NO + 2 NC","Product or component type":"Control relay","[Ue] rated operational voltage":"10 MOhm","Ambient air temperature for storage":"-76...176 °F (-60...80 °C)","Ambient air temperature for operation":"-40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a00e5d4caf378dae777587c026a3d3f8.pdf","sourceUrl":"https://www.se.com/be/en/product/CAD32ML/control-relay-tesys-deca-3no+2nc-690v-220v-dc-low-consumption-coil-screw-clamp-terminals/"},"ai":{"faq":[{"question":"What compliance standards does the CAD32ML meet?","answer":"The CAD32ML is certified to EN/IEC 60947-5-1, GB/T 14048.5, UL 60947-5-1, CSA C22.2 No 60947-5-1, and JIS C8201-5-1. It carries IP2X finger protection per VDE 0106 and TH protective treatment per IEC 60068 for tropical environments."},{"question":"What is the physical size of the CAD32ML?","answer":"Width is 45 mm (1.8 in), depth is 93 mm (3.7 in), and height is 77 mm (3.03 in). It occupies three 18 mm DIN-rail module positions."},{"question":"What utilisation categories does the CAD32ML support?","answer":"It is rated for AC-15, AC-14, and DC-13 per IEC 60947-5-1. AC-15 covers solenoid and brake loads above 72 VA; AC-14 covers smaller solenoid loads below 72 VA; DC-13 covers inductive DC loads such as contactor coils and solenoid valves."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CAD32ML","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CAD32ML when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}