{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CAD50AE7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CAD50AE7","canonicalUrl":"https://aoctrl.com/schneider/CAD50AE7","factsUrl":"https://aoctrl.com/api/mcp/products/CAD50AE7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca control relay, CAD50AE7, 5 NO contacts, ≤690 V rated operational voltage, 48 V AC 50/60 Hz standard coil, snap-in terminals.","salesMarkdown":"The Schneider CAD50AE7 is a TeSys Deca control relay with five normally open (5 NO) pole contacts, designed for switching control circuits in industrial panels. It carries a 48 V AC standard coil and is rated for operational voltages up to 690 V. The snap-in terminals simplify wiring and panel assembly. Rated for utilization categories AC-15 (electromagnetic loads), AC-14 (control circuit loads with low inrush), and DC-13 (solenoid/contactors with parallel diode suppression), this relay covers the common control-circuit switching duties in motor starter and PLC output isolation applications. The 5 NO arrangement gives you five independent make contacts in a single 45 mm wide package. Mounts on a DIN rail in the standard 45 mm footprint (width 45 mm, height 107 mm, depth 93 mm). The IP2X front-face protection (per VDE 0106) means accidental finger contact with live terminals is prevented when the relay is installed in a closed panel — standard for control-gear compartments. Operates from -40 to 60 °C with full rating, and up to 70 °C with derating. Storage range is -60 to 80 °C. Altitude rating to 3000 m without derating. The TH protective treatment (conforming to IEC 60068) means it withstands tropical humid environments — relevant for HVAC or outdoor-adjacent cabinet placement. Mechanical robustness: survives 10 Gn shocks (11 ms) in the open state and 15 Gn in the closed state. Vibration resistance is 2 Gn (5–300 Hz) open, 4 Gn closed. These figures mean the relay holds its state under moderate machine vibration — suitable for mounting near conveyor drives or pump motors without auxiliary dampening. Certified to EN/IEC 60947-5-1 (control circuit devices), UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. This covers acceptance in European, North American, Chinese, and Japanese installations — a single part number for multi-jurisdiction BOMs.","metaTitle":"Schneider CAD50AE7 TeSys Deca Control Relay, 5NO, 48V AC","metaDescription":"Schneider CAD50AE7 TeSys Deca control relay, 5 normally open contacts, 48V AC 50/60 Hz coil, rated ≤690V. Active production. Snap-in terminals. EN/IEC 60947-5-1, UL, CSA.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Control Accessories"],"specifications":{"Depth":"93 mm","Range":"TeSys","Width":"45 mm","title":"CAD50AE7","Height":"107 mm","Standards":"EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1","description":"Control relay, TeSys Deca, 5NO, <=690V, 48V AC standard coil, snap-in terminals","Product name":"TeSys CAD","lifecycle_stage":"current","Device short name":"CAD","Operating altitude":"0...3000 m","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-15 AC-14 DC-13","Contactor application":"Control circuit","Mechanical robustness":"Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP2X front face conforming to VDE 0106","Pole contact composition":"5 NO","Product or component type":"Control relay","[Ue] rated operational voltage":"10 MOhm","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3f2551b474d721b22c2b4fd87efbbbc8.pdf","sourceUrl":"https://www.se.com/be/en/product/CAD50AE7/control-relay-tesys-deca-5no-690v-48v-ac-standard-coil-snapin-terminals/"},"ai":{"faq":[{"question":"What are the key ratings for CAD50AE7?","answer":"Five normally open contacts, 48 V AC coil, rated operational voltage up to 690 V. Utilization categories AC-15, AC-14, and DC-13. Operating temperature -40 to 60 °C (70 °C with derating). Width 45 mm, depth 93 mm."},{"question":"What compliance documentation does Schneider provide for CAD50AE7?","answer":"The relay is certified to EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. TH protective treatment per IEC 60068 for tropical environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CAD50AE7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CAD50AE7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}