{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CAD50AG7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CAD50AG7","canonicalUrl":"https://aoctrl.com/schneider/CAD50AG7","factsUrl":"https://aoctrl.com/api/mcp/products/CAD50AG7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca control relay, CAD50AG7, 5NO, ≤690V, 120V AC standard coil, snap-in terminals.","salesMarkdown":"The CAD50AG7 is a TeSys Deca control relay from Schneider Electric, configured with five normally-open (5 NO) pole contacts. It is designed for control-circuit switching in industrial panels, rated for operational voltages up to 690 V with a 120 V AC standard coil. The snap-in terminal design speeds DIN-rail mounting and wiring — a practical detail when you're populating a row of contactors and relays in the same enclosure. The utilisation categories tell you exactly what loads this relay can handle: AC-15 (solenoid valves, electromagnetic clutches), AC-14 (small inductive loads below 72 VA), and DC-13 (solenoids with DC coils). These are the standard categories per IEC 60947-5-1 for control-circuit devices — so the CAD50AG7 is certified for the full range of pilot-duty switching you'd find in a motor control centre or a conveyor line. The 5 NO contact arrangement gives you five independent switching paths, which is useful when you need to interlock multiple starters or signal separate PLC inputs from one coil. Mechanical robustness is specified with shock and vibration limits: the relay stays closed under 15 Gn shocks (11 ms) and open under 10 Gn, per IEC 60068-2-27. Vibration resistance is 4 Gn closed, 2 Gn open across 5–300 Hz per IEC 60068-2-6. These numbers matter if the panel is mounted on a machine frame or near a large motor — the relay won't chatter or drop out under normal industrial vibration. Storage range extends from -60 to 80 °C. The TH protective treatment per IEC 60068 means the relay is coated against humidity and corrosive atmospheres — relevant for installations in unheated warehouses or near chemical processing areas. The CAD50AG7 carries approvals under EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. That covers the major global markets — IEC for Europe and much of Asia, UL/CSA for North America, GB/T for China, JIS for Japan. For a procurement desk filling a BOM for a machine headed to multiple regions, this single part number satisfies the certification requirements across all those jurisdictions.","metaTitle":"Schneider CAD50AG7 TeSys Deca Control Relay, 5NO, 120V AC","metaDescription":"Active production control relay, 5NO contacts, 120V AC coil, 690V rated. Complies with EN/IEC 60947-5-1, UL, CSA. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Control Accessories"],"specifications":{"Depth":"93 mm","Range":"TeSys","Width":"45 mm","title":"CAD50AG7","Height":"107 mm","Standards":"EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1","description":"Control relay, TeSys Deca, 5NO, <=690V, 120V AC standard coil, snap-in terminals","Product name":"TeSys CAD","lifecycle_stage":"current","Device short name":"CAD","Operating altitude":"0...3000 m","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-15 AC-14 DC-13","Contactor application":"Control circuit","Mechanical robustness":"Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP2X front face conforming to VDE 0106","Pole contact composition":"5 NO","Product or component type":"Control relay","[Ue] rated operational voltage":"10 MOhm","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6cdcdef8647d6c89084686c7a6b9f2f4.pdf","sourceUrl":"https://www.se.com/be/en/product/CAD50AG7/control-relay-tesys-deca-5no-690v-120v-ac-standard-coil-snapin-terminals/"},"ai":{"faq":[{"question":"What standards does the CAD50AG7 comply with?","answer":"It complies with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. This covers IEC, North American, Chinese, and Japanese control-device standards."},{"question":"What is the contact configuration and coil voltage?","answer":"The relay has 5 normally-open (5 NO) contacts and a 120 V AC standard coil. It is rated for operational voltages up to 690 V."},{"question":"What utilisation categories does the CAD50AG7 support?","answer":"It supports AC-15, AC-14, and DC-13 per IEC 60947-5-1. These cover solenoid valves, small inductive loads, and DC solenoid switching respectively."},{"question":"What are the environmental limits for operation and storage?","answer":"Operating temperature is -40 to 60 °C (with derating to 70 °C). Storage temperature range is -60 to 80 °C. Operating altitude is 0 to 3000 m."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CAD50AG7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CAD50AG7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}