{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CAD50AJ7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CAD50AJ7","canonicalUrl":"https://aoctrl.com/schneider/CAD50AJ7","factsUrl":"https://aoctrl.com/api/mcp/products/CAD50AJ7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca control relay, CAD50AJ7, 5 NO, ≤690V, 12V AC standard coil, snap-in terminals.","salesMarkdown":"The CAD50AJ7 is a TeSys Deca control relay from Schneider Electric, built for switching loads in control circuits. It carries five normally-open (5 NO) pole contacts and a 12V AC standard coil, with a rated operational voltage up to 690V. The utilisation categories — AC-15, AC-14, and DC-13 — define its switching capability: AC-15 covers solenoid and electromagnetic loads above 72 VA, AC-14 handles smaller solenoid loads below 72 VA, and DC-13 is for solenoids with parallel diodes. That means this relay is sized for the inductive loads typical in contactor coils, valve actuators, and small motor starters, not resistive heating elements. Ambient operating range is -40 to 60 °C, with derating allowed up to 70 °C, and storage from -60 to 80 °C. Altitude rating goes to 3000 m without derating. The CAD50AJ7 is certified to EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1 — the core standards for control-circuit devices and switching elements. It also carries TH protective treatment conforming to IEC 60068 for tropical environments. Mechanical robustness is tested to 10 Gn shocks (relay open) and 15 Gn (closed), with vibration resistance at 2 Gn open and 4 Gn closed across 5-300 Hz.","metaTitle":"TeSys CAD50AJ7 Control Relay, 5NO, 12V AC, 690V","metaDescription":"Active TeSys Deca control relay CAD50AJ7, 5 NO contacts, 12V AC coil, rated to 690V. AC-15/DC-13 utilisation. EN/IEC/UL/CSA certified. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Control Accessories"],"specifications":{"Depth":"93 mm","Range":"TeSys","Width":"45 mm","Height":"107 mm","Standards":"EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1","Product name":"TeSys CAD","lifecycle_stage":"current","Device short name":"CAD","Operating altitude":"0...3000 m","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-15 AC-14 DC-13","Contactor application":"Control circuit","Mechanical robustness":"Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP2X front face conforming to VDE 0106","Pole contact composition":"5 NO","Product or component type":"Control relay","[Ue] rated operational voltage":"10 MOhm","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/CAD50AJ7/control-relay-tesys-deca-5no-690v-12v-ac-standard-coil-snapin-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/CAD50AJ7/alternatives.json"},"ai":{"faq":[{"question":"What utilisation categories does this relay support?","answer":"It is rated for AC-15, AC-14, and DC-13. AC-15 covers solenoid loads above 72 VA, AC-14 covers solenoid loads below 72 VA, and DC-13 covers DC solenoids with parallel diodes."},{"question":"What are the key dimensions?","answer":"Width is 45 mm, height is 107 mm, depth is 93 mm. It fits the standard TeSys Deca DIN-rail footprint."},{"question":"What compliance documentation is available?","answer":"The relay is certified to EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. It also meets TH protective treatment per IEC 60068."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CAD50AJ7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CAD50AJ7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}