{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CAD50AJL","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CAD50AJL","canonicalUrl":"https://aoctrl.com/schneider/CAD50AJL","factsUrl":"https://aoctrl.com/api/mcp/products/CAD50AJL","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca CAD control relay, 5NO, <=690V, 12V DC low consumption coil, snap-in terminals.","salesMarkdown":"The Schneider CAD50AJL is a TeSys Deca control relay with five normally-open (5 NO) pole contacts, designed for control-circuit switching up to 690 V. It uses a 12 V DC low-consumption coil and terminates via snap-in terminals — no tools needed for the connection, which matters when you're swapping a relay in a crowded panel without losing the screwdriver down the backplane. Rated for utilisation categories AC-15, AC-14, and DC-13, so it handles solenoid and contactor coils (AC-15), small electromagnetic loads (AC-14), and DC inductive loads like brake coils or clutch actuators. The DC-13 rating is what you check when the relay drives a DC valve bank — not every control relay carries it. Measures 45 mm wide, 107 mm tall, 93 mm deep — standard TeSys Deca footprint that clips onto a DIN rail. The 93 mm depth means it clears a 100 mm deep enclosure without the front cover pressing on the coil terminals. IP2X on the front face keeps fingers out per VDE 0106; fine for a closed panel, not rated for washdown. Operates from -40 °C to 60 °C ambient, with derating allowed up to 70 °C. Storage range is wider at -60 °C to 80 °C — that's the shipping and warehouse limit, not the running limit. Mechanical robustness is specified: shocks up to 10 Gn (11 ms) when open, 15 Gn when closed; vibrations 2 Gn open, 4 Gn closed across 5–300 Hz. That's enough for most industrial machinery but not for direct mounting on a large reciprocating compressor — check the vibration profile if that's the mount point. Compliant with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. The UL and CSA marks mean it's accepted in North American panels without a separate evaluation. Protective treatment is TH per IEC 60068 — tropicalised for humid environments, which matters in a brewery or paper mill control cabinet.","metaTitle":"Schneider CAD50AJL TeSys Deca Control Relay, 5NO, 12V DC","metaDescription":"Schneider CAD50AJL TeSys Deca control relay, 5NO contacts, 12V DC coil, rated <=690V. Active production. Complies with EN/IEC 60947-5-1, UL, CSA. Depth 93 mm.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Control Accessories"],"specifications":{"Depth":"93 mm","Range":"TeSys","Width":"45 mm","Height":"107 mm","Standards":"EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1","Product name":"TeSys CAD","lifecycle_stage":"current","Device short name":"CAD","Operating altitude":"0...3000 m","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-15 AC-14 DC-13","Contactor application":"Control circuit","Mechanical robustness":"Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP2X front face conforming to VDE 0106","Pole contact composition":"5 NO","Product or component type":"Control relay","[Ue] rated operational voltage":"10 MOhm","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/CAD50AJL/control-relay-tesys-deca-5no-690v-12v-dc-low-consumption-coil-snapin-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/CAD50AJL/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the CAD50AJL?","answer":"Five NO contacts, rated operational voltage up to 690 V, 12 V DC coil. Utilisation categories AC-15, AC-14, and DC-13. Ambient operating temperature -40 °C to 60 °C (derated to 70 °C). Depth 93 mm, width 45 mm, height 107 mm."},{"question":"What standards does the CAD50AJL comply with?","answer":"It complies with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. Protective treatment is TH conforming to IEC 60068 for tropical environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CAD50AJL","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CAD50AJL when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}