{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CAD50AM7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CAD50AM7","canonicalUrl":"https://aoctrl.com/schneider/CAD50AM7","factsUrl":"https://aoctrl.com/api/mcp/products/CAD50AM7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca CAD50AM7 control relay, 5 normally open contacts, 220V AC standard coil, snap-in terminals, 45 mm width.","salesMarkdown":"It uses a 220 V AC standard coil and snap-in terminals for quick DIN-rail mounting and wiring. Rated for utilisation categories AC-15, AC-14, and DC-13 per EN/IEC 60947-5-1, this relay handles solenoid valve, contactor coil, and moderate inductive loads common in control logic. The front face carries IP2X protection (finger-safe per VDE 0106), so it's suitable for open-panel mounting where accidental touch is a concern. Operating temperature spans -40 to 60 °C, with derating required above 60 °C up to 70 °C — a real factor if the relay sits near a heat source or in a sealed enclosure. ## Standards and compliance — what the approvals mean The CAD50AM7 carries full global approvals: EN/IEC 60947-5-1 (the main control-circuit device standard), UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5 (China), and JIS C8201-5-1 (Japan). That means it's accepted in panels destined for North America, Europe, China, and Japan without a separate review cycle — one part for multi-region builds. The relay measures 45 mm wide, 107 mm high, and 93 mm deep — a standard TeSys Deca footprint that fits alongside contactors and overloads on the same DIN rail. The 45 mm width is three module spaces (at 15 mm per module), which matters when laying out a dense control row. Snap-in terminals mean no screws for the main connections — just strip, insert, and lock. The protective treatment is TH conforming to IEC 60068, so the relay handles tropical humid environments without corrosion issues.","metaTitle":"Schneider Electric CAD50AM7 TeSys Deca Control Relay, 5NO, 2","metaDescription":"Schneider Electric CAD50AM7 TeSys Deca control relay, 5NO contacts, 220V AC standard coil, snap-in terminals. Active production, EN/IEC 60947-5-1, UL, CSA. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Control Accessories"],"specifications":{"Depth":"93 mm","Range":"TeSys","Width":"45 mm","Height":"107 mm","Standards":"EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1","Product name":"TeSys CAD","lifecycle_stage":"current","Device short name":"CAD","Operating altitude":"0...3000 m","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-15 AC-14 DC-13","Contactor application":"Control circuit","Mechanical robustness":"Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP2X front face conforming to VDE 0106","Pole contact composition":"5 NO","Product or component type":"Control relay","[Ue] rated operational voltage":"10 MOhm","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/49c1420ffaf3e02ab3b022476dd8f0d8.pdf","sourceUrl":"https://www.se.com/be/en/product/CAD50AM7/control-relay-tesys-deca-5no-690v-220v-ac-standard-coil-snapin-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/CAD50AM7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the CAD50AM7?","answer":"It is a 5 NO control relay with a 220 V AC standard coil. It is rated for utilisation categories AC-15, AC-14, and DC-13 per EN/IEC 60947-5-1, with an operating temperature range of -40 to 60 °C (derated to 70 °C). The front face is IP2X protected."},{"question":"What compliance standards does the CAD50AM7 meet?","answer":"It complies with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. This covers acceptance in European, North American, Chinese, and Japanese panel builds."},{"question":"What is the physical size of the CAD50AM7?","answer":"Width is 45 mm, height is 107 mm, and depth is 93 mm. The 45 mm width occupies three 15 mm module spaces on a DIN rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CAD50AM7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CAD50AM7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}