{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CAD50AS7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CAD50AS7","canonicalUrl":"https://aoctrl.com/schneider/CAD50AS7","factsUrl":"https://aoctrl.com/api/mcp/products/CAD50AS7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca control relay, CAD50AS7, 5NO, ≤690V, 500V AC standard coil, snap-in terminals.","salesMarkdown":"It carries utilisation categories AC-15, AC-14, and DC-13, which means it is rated for electromagnetic loads like contactor coils (AC-15) and resistive/inductive DC loads (DC-13) — the ratings that govern real-world switching life, not just the maximum voltage. The relay uses snap-in terminals for panel wiring and is rated IP2X on the front face per VDE 0106, so it provides basic finger-probe protection on the panel door. Storage range is -60 to 80 °C. The CAD50AS7 is certified to EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. These are the control-circuit switching standards that cover its rated operational voltage, making the relay accepted in IEC, UL, CSA, Chinese (GB), and Japanese (JIS) jurisdictions without additional qualification. ## Mechanical robustness The relay withstands 10 Gn shocks for 11 ms in the open state and 15 Gn for 11 ms in the closed state per IEC 60068-2-27. Vibration resistance is 2 Gn (5–300 Hz) open and 4 Gn (5–300 Hz) closed per IEC 60068-2-6. These ratings matter for applications mounted on machinery or in panels subject to transport or process vibration — the contacts stay where they are supposed to. ## Integration notes The 5 NO contact arrangement gives you five independent control-circuit switching paths from one coil; useful for distributed control schemes where a single relay must signal multiple PLC inputs or contactor coils.","metaTitle":"Schneider TeSys CAD50AS7 Control Relay, 5NO, 690V","metaDescription":"Active-production control relay from Schneider TeSys Deca series. 5 normally-open contacts, rated up to 690V. AC-15/DC-13 utilisation. Snap-in terminals. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Control Accessories"],"specifications":{"Depth":"93 mm","Range":"TeSys","Width":"45 mm","Height":"107 mm","Standards":"EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1","Product name":"TeSys CAD","lifecycle_stage":"current","Device short name":"CAD","Operating altitude":"0...3000 m","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-15 AC-14 DC-13","Contactor application":"Control circuit","Mechanical robustness":"Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP2X front face conforming to VDE 0106","Pole contact composition":"5 NO","Product or component type":"Control relay","[Ue] rated operational voltage":"10 MOhm","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/CAD50AS7/control-relay-tesys-deca-5no-690v-500v-ac-standard-coil-snapin-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/CAD50AS7/alternatives.json"},"ai":{"faq":[{"question":"What standards does the CAD50AS7 comply with?","answer":"It complies with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. This covers the main global control-circuit switching standards."},{"question":"What is the utilisation category of this relay?","answer":"The CAD50AS7 is rated for AC-15 (electromagnetic loads like contactor coils), AC-14 (small electromagnetic loads), and DC-13 (solenoid and inductive DC loads). These categories define the switching capability for real-world control circuits."},{"question":"How many contacts does the CAD50AS7 have?","answer":"It has five normally-open (5 NO) pole contacts. All five are independent switching paths controlled by the same coil."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CAD50AS7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CAD50AS7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}