{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CAD50ASD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CAD50ASD","canonicalUrl":"https://aoctrl.com/schneider/CAD50ASD","factsUrl":"https://aoctrl.com/api/mcp/products/CAD50ASD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca control relay, CAD50ASD, 5NO, ≤690V, 72V DC standard coil, snap-in terminals.","salesMarkdown":"It's designed for control circuit switching in industrial panels, handling AC-15, AC-14, and DC-13 utilisation categories — meaning it's rated for solenoid and electromagnetic loads (AC-15), low-inductive loads (AC-14), and DC inductive loads like contactor coils (DC-13). The snap-in terminals simplify panel wiring, and the IP2X front face (per VDE 0106) provides basic finger protection on the panel door. The 5NO contact configuration gives you five independent sets of normally open auxiliary contacts — useful for signalling, interlocking, or driving multiple loads from one relay. The 72 V DC coil is a common control voltage in DC-powered panels or systems with battery-backed control supplies. Rated operational voltage up to 690 V means it can switch control circuits on 400 V or 480 V systems without derating. The operating temperature range of -40 to 60 °C (with derating up to 70 °C) covers most indoor industrial environments, and the 0...3000 m altitude rating handles high-altitude installations without special consideration. ## Mechanical ruggedness and compliance This relay withstands 10 Gn shocks for 11 ms when open, and 15 Gn when closed, per IEC 60068-2-27. Vibration resistance is 2 Gn (open) and 4 Gn (closed) across 5...300 Hz per IEC 60068-2-6. That's enough for installation on machinery or in panels subject to moderate vibration. Standards compliance covers EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1 — so it's accepted in North American, European, Chinese, and Japanese markets. The TH protective treatment (conforming to IEC 60068) means it's treated for tropical/humid environments.","metaTitle":"Schneider CAD50ASD TeSys Deca Control Relay, 5NO, 72V DC","metaDescription":"Schneider Electric CAD50ASD TeSys Deca control relay, 5 normally open contacts, 72 V DC coil, rated up to 690 V. Active production. Snap-in terminals. UL/CSA/IEC certified.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Control Accessories"],"specifications":{"Depth":"93 mm","Range":"TeSys","Width":"45 mm","title":"CAD50ASD","Height":"107 mm","Standards":"EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1","description":"Control relay, TeSys Deca, 5NO, <=690V, 72V DC standard coil, snap-in terminals","Product name":"TeSys CAD","lifecycle_stage":"current","Device short name":"CAD","Operating altitude":"0...3000 m","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-15 AC-14 DC-13","Contactor application":"Control circuit","Mechanical robustness":"Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP2X front face conforming to VDE 0106","Pole contact composition":"5 NO","Product or component type":"Control relay","[Ue] rated operational voltage":"10 MOhm","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/71375404fe905f6cc3fe314f48faa7f3.pdf","sourceUrl":"https://www.se.com/be/en/product/CAD50ASD/control-relay-tesys-deca-5no-690v-72v-dc-standard-coil-snapin-terminals/"},"ai":{"faq":[{"question":"What are the key ratings of the CAD50ASD?","answer":"It is a 5NO control relay with a 72 V DC coil, rated operational voltage up to 690 V, and utilisation categories AC-15, AC-14, and DC-13. Operating temperature range is -40 to 60 °C (derating to 70 °C)."},{"question":"What standards does the CAD50ASD comply with?","answer":"It complies with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1."},{"question":"What is the physical size of the CAD50ASD?","answer":"Dimensions are 45 mm width, 107 mm height, and 93 mm depth."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CAD50ASD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CAD50ASD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}