{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CAD50AU7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CAD50AU7","canonicalUrl":"https://aoctrl.com/schneider/CAD50AU7","factsUrl":"https://aoctrl.com/api/mcp/products/CAD50AU7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca control relay, CAD50AU7, 5 NO, ≤690V, 240V AC standard coil, snap-in terminals.","salesMarkdown":"The CAD50AU7 is a TeSys Deca control relay from Schneider Electric, built for switching control circuits in industrial panels. It carries five normally-open (5 NO) pole contacts and a 240V AC standard coil, terminated through snap-in terminals for quick panel wiring. Rated utilisation categories AC-15, AC-14, and DC-13 mean it handles solenoid valves, contactor coils, and small DC loads typical in control logic — not motor power switching. Operating temperature spans -40 to 60 °C standard, with derating allowed up to 70 °C. Storage range extends -60 to 80 °C. The front face carries IP2X finger protection per VDE 0106, so it's safe for open-panel builds where operators might reach near live terminals. ## Standards and compliance footprint Certified to EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. That covers North American, European, Chinese, and Japanese acceptance — one part number for multi-jurisdiction machine builds. Protective treatment conforms to TH per IEC 60068 for tropical environments. Shock and vibration ratings are specified: relay holds closed at 15 Gn, open at 10 Gn for 11 ms; vibration resistance is 4 Gn closed, 2 Gn open across 5–300 Hz. ## Mechanical fit and integration notes Dimensions are 107 mm high, 45 mm wide, 93 mm deep. Operating altitude is rated to 3000 m without derating.","metaTitle":"Schneider TeSys CAD50AU7 Control Relay, 5NO, 240V AC Coil","metaDescription":"Active TeSys Deca control relay, 5 NO contacts, 240V AC coil, snap-in terminals. Rated AC-15/DC-13 for control circuits. UL/CSA/IEC certified. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Control Accessories"],"specifications":{"Depth":"93 mm","Range":"TeSys","Width":"45 mm","title":"CAD50AU7","Height":"107 mm","Standards":"EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1","description":"Control relay, TeSys Deca, 5NO, <=690V, 240V AC standard coil, snap-in terminals","Product name":"TeSys CAD","lifecycle_stage":"current","Device short name":"CAD","Operating altitude":"0...3000 m","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-15 AC-14 DC-13","Contactor application":"Control circuit","Mechanical robustness":"Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP2X front face conforming to VDE 0106","Pole contact composition":"5 NO","Product or component type":"Control relay","[Ue] rated operational voltage":"10 MOhm","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b966cf3f839fb67b3cb3e5087db9b56c.pdf","sourceUrl":"https://www.se.com/be/en/product/CAD50AU7/control-relay-tesys-deca-5no-690v-240v-ac-standard-coil-snapin-terminals/"},"ai":{"faq":[{"question":"What standards does CAD50AU7 comply with?","answer":"It is certified to EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1. Protective treatment conforms to TH per IEC 60068 for tropical environments."},{"question":"What is the operating temperature range for CAD50AU7?","answer":"Operating ambient is -40 to 60 °C, with derating allowed up to 70 °C. Storage temperature range is -60 to 80 °C."},{"question":"What contact configuration does CAD50AU7 have?","answer":"It has five normally-open (5 NO) poles, rated for utilisation categories AC-15, AC-14, and DC-13 — suitable for switching solenoid valves, contactor coils, and small DC loads in control circuits."},{"question":"How do I source CAD50AU7?","answer":"The part is active and sourced to order. Submit an RFQ for current availability and lead time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CAD50AU7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CAD50AU7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}