{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CAD50AUD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CAD50AUD","canonicalUrl":"https://aoctrl.com/schneider/CAD50AUD","factsUrl":"https://aoctrl.com/api/mcp/products/CAD50AUD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca control relay, CAD50AUD, 5 NO contacts, ≤690 V, 250 V DC standard coil, snap-in terminals, 45 mm width.","salesMarkdown":"It uses snap-in terminals for wiring and is designed for control circuit applications — switching pilot devices, contactor coils, and signal loads in a panel. It carries certifications across EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1, so it is accepted in European, North American, Chinese, and Japanese installations without additional agency review. The 5 NO contact configuration means this relay switches five independent control circuits simultaneously — common for interlocking multiple contactors or enabling several safety/permissive signals from one command. The utilisation categories (AC-15, AC-14, DC-13) tell you it is rated for switching electromagnetic loads (contactors, solenoids) and resistive/inductive pilot-duty circuits, not power-level motor loads. Operating temperature spans -40 to 60 °C, with derating required above 60 °C up to 70 °C — relevant if the relay sits near a heat source or in a non-ventilated enclosure. Storage range is -60 to 80 °C, which covers most shipping and warehouse conditions. Mechanical robustness is specified: the relay withstands 10 Gn shocks for 11 ms in the open state and 15 Gn closed, plus vibration of 2 Gn (open) and 4 Gn (closed) across 5–300 Hz. That makes it suitable for installation on machinery with moderate vibration — conveyors, compressors, or pump skids — without contact chatter. The IP2X front-face protection (per VDE 0106) means the front is finger-safe — a panel builder can work nearby without accidental contact with live terminals behind the relay. At 45 mm wide, 107 mm tall, and 93 mm deep, the CAD50AUD occupies a standard DIN-rail footprint. The 45 mm width is three 15 mm modular units — plan your enclosure rail space accordingly. Depth of 93 mm means it fits most 120 mm deep enclosures with clearance for wiring behind the relay. The TH protective treatment (conforming to IEC 60068) means the relay is treated against humidity and tropical conditions — no extra conformal coating needed for most indoor industrial environments.","metaTitle":"Schneider Electric CAD50AUD TeSys Deca Control Relay, 5NO, 6","metaDescription":"Active-production control relay from the TeSys Deca range. 5 NO contacts, rated up to 690 V. EN/IEC 60947-5-1, UL, CSA, GB/T, JIS certified. Panel-mount, 45 mm wide. Sourced to ord","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Control Accessories"],"specifications":{"Depth":"93 mm","Range":"TeSys","Width":"45 mm","Height":"107 mm","Standards":"EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1","Product name":"TeSys CAD","lifecycle_stage":"current","Device short name":"CAD","Operating altitude":"0...3000 m","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-15 AC-14 DC-13","Contactor application":"Control circuit","Mechanical robustness":"Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP2X front face conforming to VDE 0106","Pole contact composition":"5 NO","Product or component type":"Control relay","[Ue] rated operational voltage":"10 MOhm","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/CAD50AUD/control-relay-tesys-deca-5no-690v-250v-dc-standard-coil-snapin-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/CAD50AUD/alternatives.json"},"ai":{"faq":[{"question":"What certifications does the CAD50AUD carry?","answer":"It is certified to EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1, covering European, North American, Chinese, and Japanese regulatory requirements."},{"question":"What is the physical size of the CAD50AUD?","answer":"It measures 45 mm wide, 107 mm tall, and 93 mm deep — three 15 mm modular units on a DIN rail."},{"question":"What contact configuration does the CAD50AUD have?","answer":"It has five normally-open (5 NO) contacts, suitable for switching multiple control circuits from a single command."},{"question":"What utilisation categories does the CAD50AUD support?","answer":"It is rated for AC-15, AC-14, and DC-13 utilisation categories — covering electromagnetic pilot-duty loads, resistive/inductive control circuits, and DC switching applications."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CAD50AUD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CAD50AUD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}