{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CAD50AX7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CAD50AX7","canonicalUrl":"https://aoctrl.com/schneider/CAD50AX7","factsUrl":"https://aoctrl.com/api/mcp/products/CAD50AX7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca CAD50AX7 control relay, 5 normally open contacts, rated <=690 V, 600 V AC standard coil, snap-in terminals.","salesMarkdown":"## Control relay, 5 NO, TeSys Deca The CAD50AX7 is a TeSys Deca control relay from Schneider Electric, packing five normally open (5 NO) pole contacts into a 45 mm wide package. It's rated for operational voltages up to 690 V with a 600 V AC standard coil, and the snap-in terminals cut wiring time on the panel. The 93 mm depth keeps it from crowding the backplane. This is a control-circuit relay, not a power contactor — the utilisation categories tell you the load type it's designed for: AC-15 (solenoid valves, electromagnetic clutches), AC-14 (small contactor coils), and DC-13 (solenoids with DC supplies). The 5 NO contact arrangement means it's a straight-forward pick for latching or interlock circuits where you need multiple isolated outputs from one coil signal. The IP2X front-face protection means it's finger-safe from the front when mounted in an enclosure — standard for control relays on a DIN rail. The TH protective treatment per IEC 60068 means the relay is built to handle tropical climates (heat and humidity), so it's a solid pick for non-conditioned electrical rooms or outdoor-rated panels. Mechanical robustness specs are worth noting: the relay stays closed under 15 Gn shocks and open under 10 Gn, and it handles 4 Gn vibration closed, 2 Gn open. That's better than many general-purpose relays — it'll hold state on a conveyor line or near a compressor without nuisance dropouts. Operating temperature spans -40 to 60 °C, with derating needed above 60 up to 70 °C. Storage range is -60 to 80 °C. The 0 to 3000 m altitude rating covers most installations without derating. The CAD50AX7 carries approvals across the major industrial regions: EN/IEC 60947-5-1 (Europe), UL 60947-5-1 (US), CSA C22.2 No 60947-5-1 (Canada), GB/T 14048.5 (China), and JIS C8201-5-1 (Japan). That's a global spec sheet — no need to swap variants for different markets.","metaTitle":"Schneider Electric CAD50AX7 TeSys CAD Control Relay, 5NO, 69","metaDescription":"Schneider Electric CAD50AX7 TeSys Deca control relay, 5NO contacts, rated <=690V, 600V AC coil. Active production. UL/CSA/EN/IEC 60947-5-1. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Control Accessories"],"specifications":{"Depth":"93 mm","Range":"TeSys","Width":"45 mm","Height":"107 mm","Standards":"EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1","Product name":"TeSys CAD","lifecycle_stage":"current","Device short name":"CAD","Operating altitude":"0...3000 m","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-15 AC-14 DC-13","Contactor application":"Control circuit","Mechanical robustness":"Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP2X front face conforming to VDE 0106","Pole contact composition":"5 NO","Product or component type":"Control relay","[Ue] rated operational voltage":"10 MOhm","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/CAD50AX7/control-relay-tesys-deca-5no-690v-600v-ac-standard-coil-snapin-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/CAD50AX7/alternatives.json"},"ai":{"faq":[{"question":"What standards does CAD50AX7 comply with?","answer":"It complies with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1 — covering Europe, North America, China, and Japan."},{"question":"What is the contact arrangement on CAD50AX7?","answer":"Five normally open (5 NO) contacts. No NC contacts on this variant."},{"question":"What utilisation categories does it support?","answer":"AC-15 (solenoid valves, electromagnetic clutches), AC-14 (small contactor coils), and DC-13 (DC solenoids). This is a control-circuit relay, not a power contactor."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CAD50AX7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CAD50AX7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}