{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CAD50FC7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CAD50FC7","canonicalUrl":"https://aoctrl.com/schneider/CAD50FC7","factsUrl":"https://aoctrl.com/api/mcp/products/CAD50FC7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca CAD50FC7 control relay, 5 NO, 127V AC standard coil, screw clamp terminals, obsolete.","salesMarkdown":"The CAD50FC7 is a TeSys Deca control relay from Schneider Electric, configured with 5 normally open (NO) contacts and a 127V AC standard coil. It's designed for control circuit switching duties in industrial panels, rated for utilisation categories AC-14, AC-15, and DC-13 — meaning it handles solenoid loads, electromagnetic clutches, and contactor coils in both AC and DC control loops. The relay carries approvals across EN/IEC 60947-5-1, GB/T 14048.5, UL 60947-5-1, CSA C22.2 No 60947-5-1, and JIS C8201-5-1, so it's accepted in European, North American, and Asian installations. Front-face protection is IP2X per VDE 0106 — finger-safe when mounted in an enclosed panel. Mechanical robustness is specified for shock and vibration: the relay withstands 10 Gn for 11 ms in the open position, 15 Gn for 11 ms closed, and vibration at 2 Gn (open) / 4 Gn (closed) across 5–300 Hz per IEC 60068-2-27 and -2-6. Operating temperature spans -40 to 60 °C, with derating allowed up to 70 °C. Storage range is -60 to 80 °C. Altitude rating is 0–3000 m without derating. Protective treatment is TH per IEC 60068, meaning it's tropicalized against heat and humidity — relevant for installations in warm, damp environments like Southeast Asia or coastal plants.","metaTitle":"TeSys CAD50FC7 Control Relay, 5NO, 127V AC Coil, Obsolete","metaDescription":"TeSys Deca CAD50FC7 control relay, 5 NO contacts, 127V AC coil, screw clamp terminals. Obsolete status; sourced to order against RFQ. Complies with EN/IEC 60947-5-1, UL, CSA.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Motor Control Accessories"],"specifications":{"Depth":"3.3 in (84 mm)","Range":"TeSys","Width":"1.8 in (45 mm)","Height":"3.03 in (77 mm)","Standards":"EN/IEC 60947-5-1 GB/T 14048.5 UL 60947-5-1 CSA C22.2 No 60947-5-1 JIS C8201-5-1","Product name":"TeSys CAD","lifecycle_stage":"current","Device short name":"CAD","Operating altitude":"0...3000 m","Protective treatment":"TH IEC 60068","Utilisation category":"AC-14 DC-13 AC-15","Contactor application":"Control circuit","Mechanical robustness":"Shocks control relay open10 Gn for 11 ms IEC 60068-2-27 Shocks control relay closed15 Gn for 11 ms IEC 60068-2-27 Vibrations control relay open2 Gn, 5...300 Hz IEC 60068-2-6 Vibrations control relay closed4 Gn, 5...300 Hz IEC 60068-2-6","IP degree of protection":"IP2X front face VDE 0106","Pole contact composition":"5 NO","Product or component type":"Control relay","[Ue] rated operational voltage":"10 MOhm","Ambient air temperature for storage":"-76...176 °F (-60...80 °C)","Ambient air temperature for operation":"-40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c0807703655b3a1aa4b97267aa9b72ab.pdf","sourceUrl":"https://www.se.com/ca/en/product/CAD50FC7/control-relay-tesys-deca-5no-690v-127v-ac-standard-coil-screw-clamp-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/CAD50FC7/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to the CAD50FC7?","answer":"No official successor order code is published for this specific 127V AC coil variant. A current TeSys Deca or TeSys D control relay with 5 NO contacts and a 127V AC coil would be the functional equivalent, but the exact replacement depends on verifying coil voltage, contact configuration, and physical fit (84 mm depth, 45 mm width, 77 mm height)."},{"question":"What compliance standards does the CAD50FC7 meet?","answer":"It complies with EN/IEC 60947-5-1, GB/T 14048.5, UL 60947-5-1, CSA C22.2 No 60947-5-1, and JIS C8201-5-1. Front-face protection is IP2X per VDE 0106."},{"question":"What are the physical dimensions of the CAD50FC7?","answer":"Depth is 3.3 in (84 mm), width is 1.8 in (45 mm), height is 3.03 in (77 mm)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CAD50FC7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CAD50FC7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}