{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CAE22F5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CAE22F5","canonicalUrl":"https://aoctrl.com/schneider/CAE22F5","factsUrl":"https://aoctrl.com/api/mcp/products/CAE22F5","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, CAE22F5, 2NO+2NC, <=690V, 110V AC 50Hz coil.","salesMarkdown":"The CAE22F5 is a control relay from Schneider Electric's Easy TeSys range, designed for switching control circuits in industrial panels. It carries 2 normally-open and 2 normally-closed contacts, with a 110 V AC 50 Hz coil. Rated for utilisation categories AC-15 and AC-14, this relay is built for switching electromagnetic loads (contactors, solenoid valves) and resistive/lightly inductive loads in control circuits — not for direct motor power switching. The AC-15 rating means the contacts are tested for switching inductive loads like contactor coils — the typical job for a control relay. AC-14 covers smaller solenoid loads. Both categories are defined under EN/IEC 60947-5-1, which this relay complies with. The 2NO+2NC contact arrangement gives you flexibility: use the NO pair to latch a holding circuit and the NC pair for a status feedback or interlock, all in one 45 mm wide package. Operates from -20 to 70 °C and stores from -60 to 80 °C, with no derating needed up to 3000 m altitude. The IP2X finger protection means it's safe for open-panel mounting where accidental contact is a concern. Mechanical robustness is specified: the relay withstands 7 Gn shocks when open and 10 Gn when closed, plus 1.5 Gn vibration open and 3 Gn closed across 5–300 Hz. This makes it suitable for installation on machinery or conveyors with moderate vibration. The 45 mm wide, 80 mm deep, 74 mm tall footprint fits standard DIN-rail enclosures. The grey (RAL 7011) housing is typical for control components in European-style panels. No pin-compatible alternative is listed by the manufacturer, so stick with the exact order code for a drop-in fit.","metaTitle":"Schneider Electric CAE22F5 Easy TeSys Control Relay, 2NO+2NC","metaDescription":"Active CAE22F5 control relay from Schneider Electric Easy TeSys range. 2NO+2NC contacts, 110V AC 50Hz coil, rated for AC-15/AC-14 control circuits. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["General Purpose Relays"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","title":"CAE22F5","Colour":"Grey (RAL 7011)","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.5","description":"Control relay,Easy TeSys Control,CAE,2NO+2NC,<=690V,110V AC 50Hz coil","lifecycle_stage":"current","Range of product":"Easy TeSys Control Relay","Device short name":"CAE","Operating altitude":"3000 m without derating","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-15 AC-14","Contactor application":"Control circuit","Mechanical robustness":"Shocks control relay open: 7 Gn for 11 ms Shocks control relay closed: 10 Gn for 11 ms Vibrations control relay open: 1.5 Gn, 5...300 Hz Vibrations control relay closed: 3 Gn, 5...300 Hz","IP degree of protection":"IP2X conforming to IEC 60529","Pole contact composition":"2 NO + 2 NC","Product or component type":"Control relay","[Ue] rated operational voltage":"10 MOhm","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-20...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/977c1b487b902bc1e75c5db1e864fac0.pdf","sourceUrl":"https://www.se.com/au/en/product/CAE22F5/control-relayeasy-tesys-controlcae2no+2nc690v110v-ac-50hz-coil/"},"ai":{"faq":[{"question":"What are the key ratings for the CAE22F5?","answer":"It is a control relay with 2NO+2NC contacts, a 110 V AC 50 Hz coil, rated for AC-15 and AC-14 utilisation categories. It operates from -20 to 70 °C, up to 3000 m altitude without derating, and has IP2X finger protection."},{"question":"What standards does the CAE22F5 comply with?","answer":"It complies with EN/IEC 60947-1, EN/IEC 60947-5-1, GB/T 14048.1, and GB/T 14048.5. It also carries TH protective treatment per IEC 60068 for tropical environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CAE22F5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CAE22F5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}