{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CAE31N5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CAE31N5","canonicalUrl":"https://aoctrl.com/schneider/CAE31N5","factsUrl":"https://aoctrl.com/api/mcp/products/CAE31N5","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys Control, CAE31N5, 3NO+1NC, <=690V, 415V AC 50Hz coil, IP2X.","salesMarkdown":"## Control relay for panel builders The Schneider Electric CAE31N5 is an Easy TeSys control relay with a 3 NO + 1 NC pole configuration, designed for switching control circuits in industrial panels. It carries a 415 V AC 50 Hz coil and is rated for operational voltages up to 690 V, covering most standard motor control centre (MCC) and distribution panel signal levels. Rated for utilisation categories AC-15 and AC-14 per EN/IEC 60947-5-1, meaning it handles electromagnetic loads like contactor coils and solenoid valves (AC-15) as well as resistive and lightly inductive pilot-duty loads (AC-14). This is the key selection parameter — if your circuit drives a contactor or relay coil, AC-15 is the rating that confirms the relay can handle the inrush without contact welding. Operating temperature spans -20 to 70 °C with storage from -60 to 80 °C, and the relay operates without derating up to 3000 m altitude. The IP2X finger-safe enclosure means it can be mounted in open panel sections without additional shrouding, though not in washdown zones. The CAE31N5 occupies a 45 mm wide by 74 mm high by 80 mm deep footprint — standard for Easy TeSys control relays. Spring-cage or screw-clamp terminals accept 0.2–2.5 mm² conductors; strip 8 mm for reliable cage closure. Mechanical robustness is specified at 7 Gn shock (relay open) and 10 Gn (closed), with vibration resistance of 1.5 Gn open and 3 Gn closed across 5–300 Hz. This makes it suitable for mounting on machine frames or in mobile equipment panels where shock and vibration are present.","metaTitle":"Schneider Electric CAE31N5 Easy TeSys Control Relay, 3NO+1NC","metaDescription":"Active Schneider CAE31N5 Easy TeSys control relay. 3NO+1NC contacts, 415V AC 50Hz coil, rated up to 690V. AC-15/AC-14 utilisation. IP2X. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"80 mm","Range":"Easy TeSys","Width":"45 mm","title":"CAE31N5","Colour":"Grey (RAL 7011)","Height":"74 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.5","description":"Control relay,Easy TeSys Control,CAE,3NO+1NC,<=690V,415V AC 50Hz coil","lifecycle_stage":"current","Range of product":"Easy TeSys Control Relay","Device short name":"CAE","Operating altitude":"3000 m without derating","Protective treatment":"TH conforming to IEC 60068","Utilisation category":"AC-15 AC-14","Contactor application":"Control circuit","Mechanical robustness":"Shocks control relay open: 7 Gn for 11 ms Shocks control relay closed: 10 Gn for 11 ms Vibrations control relay open: 1.5 Gn, 5...300 Hz Vibrations control relay closed: 3 Gn, 5...300 Hz","IP degree of protection":"IP2X conforming to IEC 60529","Pole contact composition":"3 NO + 1 NC","Product or component type":"Control relay","[Ue] rated operational voltage":"10 MOhm","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-20...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/53f6ee385f0243c796f4c0b1afcd430a.pdf","sourceUrl":"https://www.se.com/vn/en/product/CAE31N5/control-relayeasy-tesys-controlcae3no+1nc690v415v-ac-50hz-coil/"},"ai":{"faq":[{"question":"What are the key ratings for the CAE31N5?","answer":"The CAE31N5 is a 3 NO + 1 NC control relay with a 415 V AC 50 Hz coil, rated for operational voltages up to 690 V. It is certified for AC-15 and AC-14 utilisation categories per IEC 60947-5-1, operates from -20 to 70 °C, and carries IP2X finger-safe protection."},{"question":"What compliance standards does the CAE31N5 meet?","answer":"The CAE31N5 complies with EN/IEC 60947-1, EN/IEC 60947-5-1, GB/T 14048.1, and GB/T 14048.5. It also carries TH protective treatment per IEC 60068 for humid environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CAE31N5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CAE31N5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}