{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CJ1W-TS561","brand":"Omron","brandSlug":"omron","productSlug":"CJ1W-TS561","canonicalUrl":"https://aoctrl.com/omron/CJ1W-TS561","factsUrl":"https://aoctrl.com/api/mcp/products/CJ1W-TS561","rawCanonicalId":null},"summary":{"shortDescription":"Omron CJ1W, CJ1W series Input Module, 6 analog inputs, screw terminal, DIN rail mount, operating 0°C~55°C, order code CJ1W-TS561.","salesMarkdown":"The Omron CJ1W-TS561 is an analog input module on the CJ1W I/O family — six analog inputs landed on screw terminals, slotted into a CJ Series rack next to the CPU and the rest of the local I/O. It carries the same DIN-rail footprint and backplane connector as the rest of the CJ1W lineup, so the mechanical and bus side of the install follows family practice rather than a one-off cutout. ## What the key envelope means in the panel Operating range is 0 °C to 55 °C, which is the standard control-room envelope — the module does not need a cabinet heater or a cold-weather spec derate for a typical indoor cell, but anything outside that band is not on the menu without external conditioning. Termination is screw, not spring-cage or MIL connector, so the wireman is terminating with a standard blade driver rather than pushing ferruled leads into a cage — worth flagging on the wiring diagram if the rest of the rack has migrated to push-in. ## Sourcing posture and lifecycle flag The evidence lists the lifecycle flag but no successor order code; sourcing a like-for-like second source is an integrator step, not a datasheet statement. ## Integration checklist for the controls integrator Slot it on the CJ1W local rack next to the CPU; the analog count is six, so any tag database that assumed two channels (a PTS15 baseline) needs to be re-sized before the rack is powered up. Confirm the analog signal class — voltage, current, or TC/RTD — against the field wiring before termination; the listing names the module as analog input but does not carry the signal-class detail, which is a question for the supplier rather than a guess on the bench. Operating envelope of 0 °C to 55 °C is the standard indoor control-cabinet window; no special derating curve is published in this evidence, so the integrator should follow the family derating note rather than a per-module curve.","metaTitle":"Omron CJ1W-TS561 Analog Input Module, 6 Ch, CJ1W","metaDescription":"Omron CJ1W-TS561 CJ1W-series 6-channel analog input module, DIN-rail mount, screw terminations, 0–55 °C; EOL flag on the listing — quote to RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Type":"Input Module","title":"CJ1W-TS561","Series":"CJ1W","Weight":"0.331 lb (150.14 g)","Package":"Bulk","description":"INPUT MODULE 6 ANALOG","Mounting Type":"DIN Rail","lifecycle_stage":"eol_hot","Termination Style":"Screw Terminal","Operating Temperature":"0°C~55°C","Number of Inputs and Type":"6 - Analog","For Use With/Related Products":"CJ Series"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$375.48","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ef506bfa9bea7e5e1aa58d3c0ba7d11d.pdf","sourceUrl":null},"ai":{"faq":[{"question":"When sourcing CJ1W-TS561, what's the closest functional second-source — CJ1W-PTS15?","answer":"It is the same family and the same mechanical package, but the CJ1W-PTS15 only carries two analog inputs against the TS561's six — close in slot and wiring practice, not a channel-for-channel swap."},{"question":"What is CJ1W-TS561's listed type on this component line?","answer":"Input Module — six analog channels on screw terminations."},{"question":"What is CJ1W-TS561's listed series on this component line?","answer":"CJ1W, drop-in on the CJ Series rack."},{"question":"Will CJ1W-TS561 drop into a panel specified around CJ1W-PTS15 without rewiring?","answer":"Mechanically yes — same DIN-rail, same screw-terminal, same CJ1W backplane. Functionally no — six channels versus two means the IO table and tag database need re-mapping before commissioning."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/omron/CJ1W-TS561","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/omron/CJ1W-TS561 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}