{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CR1F2654G7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CR1F2654G7","canonicalUrl":"https://aoctrl.com/schneider/CR1F2654G7","factsUrl":"https://aoctrl.com/api/mcp/products/CR1F2654G7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F CR1F2654G7 magnetic latching contactor, 4-pole, 265 A AC-3 at 440 V, 127 V AC/DC control, panel or DIN-rail mount.","salesMarkdown":"The CR1F2654G7 is a TeSys F magnetic latching contactor — a 4-pole, 4-NO device rated for motor control and resistive loads. The magnetic latching mechanism holds the closed position without continuous coil power, which cuts standby consumption and heat in the panel. Control voltage is 127 V AC (50–400 Hz) or 127 V DC standard, with a latching coil draw of 1800 VA AC or 1800 W DC and an unlatching draw of 12 VA/W. The operating time is 40–75 ms latching, 50–100 ms unlatching. This is a part for applications where a sustained hold-in coil is undesirable — think battery-backed or UPS-fed circuits, or panels where coil heat must be minimized. The same contactor carries an AC-1 resistive rating of 350 A at ≤ 440 V, and an AC-4 rating of 245 A — the AC-4 figure matters for reversing or inching duty where the contactor makes and breaks stalled-rotor current. For UL/CSA markets, the motor power equivalents are 150 hp at 460–480 V and 175 hp at 575–600 V three-phase. Rated breaking capacity is 2450 A at 220–440 V for the power circuit, with a making capacity of 2940 A. That gives headroom for starting inrush on motors within the rated range. The associated fuse recommendation is 315 A aM or 400 A gG at ≤ 440 V — coordinate the upstream protection to the contactor's breaking capability, not the motor FLA alone. Power dissipation per pole is 22 W in AC-3 and 39 W in AC-1. In a closed panel with multiple contactors, that heat adds up — the 0.32 mOhm average impedance at 350 A 50 Hz gives you the resistive loss to calculate for your thermal budget. Rated insulation voltage (Ui) is 1000 V per IEC 60947-4 and BS 775, with a VDE 0110 group C rating of 1500 V. Ambient operating range is -15 to 70 °C, storage -60 to 80 °C. Dimensions are 8.4 in deep, 9.6 in wide, 8.0 in high — a substantial footprint that needs clearance for the lug/ring terminal connections (accepts up to 240 mm² cable or two 32 x 4 mm bars). Tightening torque is 35 N·m on the power terminals. IP20 front-face protection per IEC 60529; the contactor is intended for inside an enclosure.","metaTitle":"CR1F2654G7 TeSys F Magnetic Latching Contactor, 265 A AC-3","metaDescription":"CR1F2654G7 TeSys F magnetic latching contactor, 265 A AC-3 at 440 V, 4-pole, 127 V control. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"8.4 in (213 mm)","Range":"TeSys","Width":"9.6 in (244.5 mm)","Height":"8.0 in (203 mm)","Category":"22331-CTR,F-LINE,DC,OPEN,NONREV","Standards":"IEC 60947-4 NF C 63-110 VDE 0660 BS 5424 JEM 1038","Product name":"TeSys F","Motor power kW":"147 kW at 1000 V AC 50/60 Hz 160 kW at 690 V AC 50/60 Hz 160 kW at 500...660 V AC 50/60 Hz 140 kW at 440 V AC 50/60 Hz 140 kW at 415 V AC 50/60 Hz 132 kW at 380...400 V AC 50/60 Hz 75 kW at 220...230 V AC 50/60 Hz","Operating time":"40...75 ms latching 50...100 ms unlatching","lifecycle_stage":"current","Mounting Support":"Notched AM1-EC rail Panel mounting","Average impedance":"0.32 mOhm - Ith 350 A 50 Hz","Device short name":"CR1F","Poles description":"4P","Tightening torque":"309.8 lbf.in (35 N.m)","Device Application":"Control","Operating altitude":"9842.52 ft (3000 m) without derating","Average Consumption":"1800 VA AC 50...400 Hz latching 12 VA AC 50...400 Hz unlatching 1800 VA DC latching 12 VA DC unlatching","Protective treatment":"TH","Utilisation category":"AC-3 AC-1 AC-4","Contactor application":"Resistive load Motor control","Mechanical durability":"1 Mcycles","Nbr. of units in pkg.":"1","Associated fuse rating":"315 A aM at 400 A BS88 at 400 A gG at <= 440 V for power circuit","Maximum operating rate":"120 cyc/h 104 °F (40 °C)","Connections - terminals":"lugs-ring terminals 1 0.4 in² (240 mm²) connector 1 0.4 in² (240 mm²) bars 2 32 x 4 mm","IP degree of protection":"IP20 front face IEC 60529","Rated breaking capacity":"2450 A at 220...440 V for power circuit 2200 A at 500 V for power circuit 800 A at 1000 V for power circuit 1700 A at 660/690 V for power circuit","Product or Component Type":"Magnetic latching contactor","motor power HP (UL / CSA)":"175 hp at 575...600 V AC 50/60 Hz for 3 phase motors 150 hp at 460...480 V AC 50/60 Hz for 3 phase motors 75 hp at 220...240 V AC 50/60 Hz for 3 phase motors 60 hp at 200...208 V AC 50/60 Hz for 3 phase motors","Irms rated making capacity":"2940 A for power circuit","Power dissipation per pole":"22 W AC-3 39 W AC-1","[Uc] control circuit voltage":"127 V AC 50...400 Hz 127 V DC standard","[Ui] rated insulation voltage":"1000 V IEC 60158-1 1000 V IEC 60947-4 1000 V BS 775 1500 V VDE 0110 group C","Control circuit voltage limits":"Latching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc","Power Pole Contact Composition":"4 NO","[Ie] rated operational current":"265 A (at 350 A (at 245 A (at <104 °F (40 °C)) at <= 440 V AC AC-4","[Ue] rated operational voltage":"1000 V AC 25...200 Hz","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"5...158 °F (-15...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"2200 A 104 °F (40 °C) - 1 s 2200 A 104 °F (40 °C) - 5 s 2200 A 104 °F (40 °C) - 10 s 1230 A 104 °F (40 °C) - 30 s 950 A 104 °F (40 °C) - 1 min 620 A 104 °F (40 °C) - 3 min 480 A 104 °F (40 °C) - 10 min","[Ith] conventional free air thermal current":"350 A (at 104 °F (40 °C)) for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/930748089f788e33cd048e1cdbfedc78.pdf","sourceUrl":"https://www.se.com/vn/en/product/CR1F2654G7/bistable-contactor-cr1f-4p-ac1-440v-350-a-coil-127-v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/CR1F2654G7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings I need to check for fit?","answer":"The headline rating is 265 A AC-3 at ≤ 440 V for motor switching. Also verify the 127 V AC/DC control voltage, the 4-pole 4-NO configuration, and the 1000 V rated insulation voltage. The AC-1 resistive rating is 350 A."},{"question":"What compliance standards does this contactor meet?","answer":"It is certified to IEC 60947-4, NF C 63-110, VDE 0660, BS 5424, and JEM 1038. The UL/CSA motor horsepower ratings are also listed, confirming North American acceptance."},{"question":"What is the physical size of this contactor?","answer":"Depth is 8.4 in (213 mm), width is 9.6 in (244.5 mm), height is 8.0 in (203 mm). It mounts on a notched AM1-EC DIN rail or directly to a panel."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CR1F2654G7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CR1F2654G7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}