{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CR1F2654Q7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CR1F2654Q7","canonicalUrl":"https://aoctrl.com/schneider/CR1F2654Q7","factsUrl":"https://aoctrl.com/api/mcp/products/CR1F2654Q7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F CR1F2654Q7, magnetic latching contactor, 4 NO poles, 265 A AC-3, 380 V AC 50/60 Hz coil, IP20 front face.","salesMarkdown":"The magnetic latching mechanism means the coil only draws power during the transition; once latched, it holds position without continuous coil current, which cuts standby losses and keeps the coil cool in enclosed panels. Its headline rating is 265 A in AC-3 duty (motor starting), so it handles induction motors up to that current — roughly 160 kW at 690 V or 150 hp at 480 V under UL/CSA. The utilisation categories span AC-1 (resistive), AC-3 (squirrel-cage motor start/run), and AC-4 (plugging/inching), so it covers both steady-state and demanding reversing applications. The control circuit is 380 V AC 50/60 Hz, with latching and unlatching limits of 0.85 to 1.1 Uc. Coil consumption peaks at 1800 VA during latching, dropping to 12 VA unlatching — that transient load matters when sizing the control transformer. Mounts on a notched AM1-EC rail or directly to a panel. Dimensions are 8.4 in deep by 9.6 in wide by 8.0 in tall — a substantial footprint that needs clearance for cable entry and heat dissipation. Terminals accept lugs, ring terminals, or bars up to 240 mm², with a tightening torque of 35 N·m on the power connections. The TH protective treatment adds resistance to tropical humidity, which matters for non-climate-controlled plant floors. ## Electrical performance and protection Rated insulation voltage is 1000 V per IEC 60947-4 and BS 775, with a 1500 V group C rating per VDE 0110. That gives headroom for 690 V systems and confirms the contactor can be used in 1000 V circuits with proper coordination. Breaking capacity is 2450 A at 440 V, tapering to 800 A at 1000 V — the contactor can interrupt fault currents within those limits, but upstream fusing or a breaker must handle the full prospective fault. Associated fuse ratings are 315 A aM or 400 A gG at ≤440 V for the power circuit. Making capacity is 2940 A, so it can close into a stalled motor or shorted load without welding contacts — that's the peak inrush it can handle once. Average impedance per pole is 0.32 mΩ at 350 A, which keeps voltage drop and heat low during continuous current. Standards compliance includes VDE 0660, NF C 63-110, JEM 1038, BS 5424, and IEC 60947-4. Motor power HP ratings are given in UL/CSA terms.","metaTitle":"Schneider CR1F2654Q7 TeSys F Magnetic Latching Contactor, 26","metaDescription":"Schneider Electric TeSys F CR1F2654Q7 magnetic latching contactor. 265 A AC-3 rated operational current, 4-pole, 380 V AC coil. Current production. Sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"8.4 in (213 mm)","Range":"TeSys","Width":"9.6 in (244.5 mm)","Height":"8.0 in (203 mm)","Category":"22331-CTR,F-LINE,DC,OPEN,NONREV","Standards":"VDE 0660 NF C 63-110 JEM 1038 BS 5424 IEC 60947-4","Product name":"TeSys F","Motor power kW":"147 kW at 1000 V AC 50/60 Hz 160 kW at 690 V AC 50/60 Hz 160 kW at 500...660 V AC 50/60 Hz 140 kW at 440 V AC 50/60 Hz 140 kW at 415 V AC 50/60 Hz 132 kW at 380...400 V AC 50/60 Hz 75 kW at 220...230 V AC 50/60 Hz","Operating time":"40...75 ms latching 50...100 ms unlatching","lifecycle_stage":"current","Mounting Support":"Notched AM1-EC rail Panel mounting","Average impedance":"0.32 mOhm - Ith 350 A 50 Hz","Device short name":"CR1F","Poles description":"4P","Tightening torque":"309.8 lbf.in (35 N.m)","Device Application":"Control","Operating altitude":"9842.52 ft (3000 m) without derating","Average Consumption":"1800 VA AC 50...400 Hz latching 12 VA AC 50...400 Hz unlatching 1800 VA DC latching 12 VA DC unlatching","Protective treatment":"TH","Utilisation category":"AC-4 AC-1 AC-3","Contactor application":"Motor control Resistive load","Mechanical durability":"1 Mcycles","Nbr. of units in pkg.":"1","Associated fuse rating":"315 A aM at 400 A BS88 at 400 A gG at <= 440 V for power circuit","Maximum operating rate":"120 cyc/h 104 °F (40 °C)","Connections - terminals":"lugs-ring terminals 1 0.4 in² (240 mm²) connector 1 0.4 in² (240 mm²) bars 2 32 x 4 mm","IP degree of protection":"IP20 front face IEC 60529","Rated breaking capacity":"2450 A at 220...440 V for power circuit 2200 A at 500 V for power circuit 800 A at 1000 V for power circuit 1700 A at 660/690 V for power circuit","Product or Component Type":"Magnetic latching contactor","motor power HP (UL / CSA)":"175 hp at 575...600 V AC 50/60 Hz for 3 phase motors 150 hp at 460...480 V AC 50/60 Hz for 3 phase motors 75 hp at 220...240 V AC 50/60 Hz for 3 phase motors 60 hp at 200...208 V AC 50/60 Hz for 3 phase motors","Irms rated making capacity":"2940 A for power circuit","Power dissipation per pole":"22 W AC-3 39 W AC-1","[Uc] control circuit voltage":"380 V AC 50/60 Hz","[Ui] rated insulation voltage":"1000 V IEC 60158-1 1000 V IEC 60947-4 1000 V BS 775 1500 V VDE 0110 group C","Control circuit voltage limits":"Latching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc","Power Pole Contact Composition":"4 NO","[Ie] rated operational current":"265 A (at 350 A (at 245 A (at <104 °F (40 °C)) at <= 440 V AC AC-4","[Ue] rated operational voltage":"1000 V AC 25...200 Hz","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"5...158 °F (-15...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"2200 A 104 °F (40 °C) - 1 s 2200 A 104 °F (40 °C) - 5 s 2200 A 104 °F (40 °C) - 10 s 1230 A 104 °F (40 °C) - 30 s 950 A 104 °F (40 °C) - 1 min 620 A 104 °F (40 °C) - 3 min 480 A 104 °F (40 °C) - 10 min","[Ith] conventional free air thermal current":"350 A (at 104 °F (40 °C)) for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e0832187b703669813ebaba6bb7315ba.pdf","sourceUrl":"https://www.se.com/sg/en/product/CR1F2654Q7/bistable-contactor-cr1f-4p-ac1-440v-350-a-coil-380-400-v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/CR1F2654Q7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"Rated operational current is 265 A in AC-3 duty, with motor power up to 160 kW at 690 V AC or 150 hp at 480 V per UL/CSA. Control coil is 380 V AC 50/60 Hz. Breaking capacity is 2450 A at 440 V, making capacity is 2940 A."},{"question":"What mounting options does the CR1F2654Q7 support?","answer":"It mounts on a notched AM1-EC DIN rail or directly to a panel. The enclosure dimensions are 8.4 in deep, 9.6 in wide, and 8.0 in tall."},{"question":"What compliance documentation does this part carry?","answer":"It complies with VDE 0660, NF C 63-110, JEM 1038, BS 5424, and IEC 60947-4. Motor power ratings are given in both IEC (kW) and UL/CSA (hp) terms, indicating evaluation under those standards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CR1F2654Q7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CR1F2654Q7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}