{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CR1F2654U7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CR1F2654U7","canonicalUrl":"https://aoctrl.com/schneider/CR1F2654U7","factsUrl":"https://aoctrl.com/api/mcp/products/CR1F2654U7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F CR1F2654U7, magnetic latching contactor, 4-pole, 265 A rated operational current, 240 V AC 50/60 Hz coil.","salesMarkdown":"The Schneider CR1F2654U7 is a TeSys F magnetic latching contactor — a 4-pole, DC-operated device that holds its state without continuous coil power. Rated for motor control and resistive loads across AC-1, AC-3, and AC-4 utilisation categories, it switches up to 265 A at 440 V AC (AC-3 duty) and handles motor power up to 160 kW at 690 V AC. The latching coil draws 1800 VA on closure and 12 VA holding, meaning the control circuit only needs a pulse to change state, not a sustained signal. The 240 V AC 50/60 Hz control circuit has a latching and unlatching voltage range of 0.85 to 1.1 Uc. Power connections accept lugs, ring terminals, or bars up to 240 mm². For resistive loads (AC-1), the thermal current Ith is 350 A at 50 Hz, with average impedance of 0.32 mOhm per pole. Power dissipation runs 22 W per pole in AC-3 and 39 W in AC-1, so panel ventilation or spacing matters when grouping multiple contactors. Rated breaking capacity is 2450 A at 440 V for the power circuit, dropping to 800 A at 1000 V. Rated insulation voltage is 1000 V per IEC 60947-4 and BS 775, with a VDE 0110 group C rating of 1500 V. For UL/CSA installations, motor power ratings are 175 hp at 575-600 V AC and 150 hp at 460-480 V AC for three-phase motors. Associated fuse protection calls for 315 A aM or 400 A gG fuses at ≤ 440 V for the power circuit. The CR1F2654U7 complies with BS 5424, NF C 63-110, IEC 60947-4, VDE 0660, and JEM 1038. The contactor measures 8.4 in (213 mm) deep, 9.6 in (244.5 mm) wide, and 8.0 in (203 mm) tall. Terminal tightening torque is 309.8 lbf·in (35 N·m). Mounting options include panel mount or notched AM1-EC rail — the rail option simplifies enclosure layout changes without drilling.","metaTitle":"Schneider CR1F2654U7 TeSys F Magnetic Latching Contactor, 26","metaDescription":"Schneider CR1F2654U7 TeSys F magnetic latching contactor. 265 A rated operational current, 4-pole, 240 VAC coil. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"8.4 in (213 mm)","Range":"TeSys","Width":"9.6 in (244.5 mm)","title":"CR1F2654U7","Height":"8.0 in (203 mm)","Category":"22331-CTR,F-LINE,DC,OPEN,NONREV","Standards":"BS 5424 NF C 63-110 IEC 60947-4 VDE 0660 JEM 1038","description":"Bistable contactor CR1-F - 4P - AC-1 440V 350 A - coil 240 V","Product name":"TeSys F","Motor power kW":"147 kW at 1000 V AC 50/60 Hz 160 kW at 690 V AC 50/60 Hz 160 kW at 500...660 V AC 50/60 Hz 140 kW at 440 V AC 50/60 Hz 140 kW at 415 V AC 50/60 Hz 132 kW at 380...400 V AC 50/60 Hz 75 kW at 220...230 V AC 50/60 Hz","Operating time":"40...75 ms latching 50...100 ms unlatching","lifecycle_stage":"current","Mounting Support":"Panel mounting Notched AM1-EC rail","Average impedance":"0.32 mOhm - Ith 350 A 50 Hz","Device short name":"CR1F","Poles description":"4P","Tightening torque":"309.8 lbf.in (35 N.m)","Device Application":"Control","Operating altitude":"9842.52 ft (3000 m) without derating","Average Consumption":"1800 VA AC 50...400 Hz latching 12 VA AC 50...400 Hz unlatching 1800 VA DC latching 12 VA DC unlatching","Protective treatment":"TH","Utilisation category":"AC-1 AC-3 AC-4","Contactor application":"Motor control Resistive load","Mechanical durability":"1 Mcycles","Nbr. of units in pkg.":"1","Associated fuse rating":"315 A aM at 400 A BS88 at 400 A gG at <= 440 V for power circuit","Maximum operating rate":"120 cyc/h 104 °F (40 °C)","Connections - terminals":"lugs-ring terminals 1 0.4 in² (240 mm²) connector 1 0.4 in² (240 mm²) bars 2 32 x 4 mm","IP degree of protection":"IP20 front face IEC 60529","Rated breaking capacity":"2450 A at 220...440 V for power circuit 2200 A at 500 V for power circuit 800 A at 1000 V for power circuit 1700 A at 660/690 V for power circuit","Product or Component Type":"Magnetic latching contactor","motor power HP (UL / CSA)":"175 hp at 575...600 V AC 50/60 Hz for 3 phase motors 150 hp at 460...480 V AC 50/60 Hz for 3 phase motors 75 hp at 220...240 V AC 50/60 Hz for 3 phase motors 60 hp at 200...208 V AC 50/60 Hz for 3 phase motors","Irms rated making capacity":"2940 A for power circuit","Power dissipation per pole":"22 W AC-3 39 W AC-1","[Uc] control circuit voltage":"240 V AC 50/60 Hz","[Ui] rated insulation voltage":"1000 V IEC 60158-1 1000 V IEC 60947-4 1000 V BS 775 1500 V VDE 0110 group C","Control circuit voltage limits":"Latching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc","Power Pole Contact Composition":"4 NO","[Ie] rated operational current":"265 A (at 350 A (at 245 A (at <104 °F (40 °C)) at <= 440 V AC AC-4","[Ue] rated operational voltage":"1000 V AC 25...200 Hz","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"5...158 °F (-15...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"2200 A 104 °F (40 °C) - 1 s 2200 A 104 °F (40 °C) - 5 s 2200 A 104 °F (40 °C) - 10 s 1230 A 104 °F (40 °C) - 30 s 950 A 104 °F (40 °C) - 1 min 620 A 104 °F (40 °C) - 3 min 480 A 104 °F (40 °C) - 10 min","[Ith] conventional free air thermal current":"350 A (at 104 °F (40 °C)) for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5880771423104b1ef6a51248c761def9.pdf","sourceUrl":"https://www.se.com/th/en/product/CR1F2654U7/bistable-contactor-cr1f-4p-ac1-440v-350-a-coil-240-v/"},"ai":{"faq":[{"question":"What are the key ratings for the CR1F2654U7?","answer":"Rated operational current is 265 A in AC-3 duty at ≤ 440 V AC. Motor power reaches 160 kW at 690 V AC. Control circuit voltage is 240 V AC 50/60 Hz. Breaking capacity is 2450 A at 440 V for the power circuit."},{"question":"What standards does the CR1F2654U7 comply with?","answer":"It complies with BS 5424, NF C 63-110, IEC 60947-4, VDE 0660, and JEM 1038. Rated insulation voltage is 1000 V per IEC 60947-4 and BS 775."},{"question":"What mounting options are available for the CR1F2654U7?","answer":"The contactor can be panel mounted or snapped onto a notched AM1-EC rail. It measures 8.4 in deep, 9.6 in wide, and 8.0 in tall."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CR1F2654U7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CR1F2654U7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}