{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CR1F265FZ7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CR1F265FZ7","canonicalUrl":"https://aoctrl.com/schneider/CR1F265FZ7","factsUrl":"https://aoctrl.com/api/mcp/products/CR1F265FZ7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F magnetic latching contactor, CR1F265FZ7, 3P (3 NO), 265 A rated operational current (AC-4), 110 V DC coil, 132 kW motor power at 400 V AC.","salesMarkdown":"The CR1F265FZ7: The headline 265 A is the AC-4 rated operational current — that's the motor-switching duty cycle where the contactor closes onto a locked-rotor inrush and breaks the full-load current. If your application is resistive heating (AC-1) or light motor starting (AC-3), the contactor can handle higher currents: the average impedance per pole is 0.32 mOhm, and the power dissipation runs 22 W per pole in AC-3 and 39 W per pole in AC-1. The 110 V DC control voltage has a latching range of 0.85 to 1.1 Uc and an unlatching range of 0.85 to 1.1 Uc, so the coil will hold in at 93.5 V DC and drop out reliably at the same threshold. Average consumption is 500 W DC during latching and 40 W DC during unlatching — the coil only draws power during the switching transient, not continuously. The rated insulation voltage is 1000 V per IEC 60947-4 and BS 775, and 1500 V per VDE 0110 group C. The rated short-time withstand current (Icw) is 2200 A for 1, 5, and 10 seconds at 40 °C, tapering to 480 A for 10 minutes. That means it can ride through a downstream fault long enough for a backup fuse or breaker to clear — coordination study input, not a continuous rating. The CR1F265FZ7 is a panel-mount contactor, not DIN-rail — it bolts in. The power circuit connections accept lugs, ring terminals, or bars up to 240 mm² per pole, with a bolted connection torqued to 35 N·m (309.8 lbf·in). The footprint is 8.4 in deep by 7.9 in wide by 8.0 in tall (213 x 201.5 x 203 mm). That's a substantial block — plan the gland plate and busbar routing accordingly. The associated fuse recommendation is 315 A aM or 400 A gG at ≤ 440 V, so the upstream protection should be sized to that.","metaTitle":"Schneider TeSys F CR1F265FZ7 Magnetic Latching Contactor, 26","metaDescription":"Schneider Electric TeSys F CR1F265FZ7 magnetic latching contactor, 3-pole, 265 A rated operational current (AC-4), 110 V DC coil, 132 kW motor power at 400 V. Current production. S","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"8.4 in (213 mm)","Range":"TeSys","Width":"7.9 in (201.5 mm)","Height":"8.0 in (203 mm)","Category":"22336-CTR,F-LINE,AC,OPEN,NONREV","Product name":"TeSys F","Motor power kW":"132 kW at 400 V AC 50/60 Hz (AC-4)","Operating time":"40...75 ms latching 50...100 ms unlatching","lifecycle_stage":"current","Average impedance":"0.32 mOhm - Ith 350 A 50 Hz","Device short name":"CR1F","Poles description":"3P","Tightening torque":"309.8 lbf.in (35 N.m)","Device Application":"Control","Operating altitude":"9842.52 ft (3000 m) without derating","Average Consumption":"500 W DC latching 40 W DC unlatching","Control circuit type":"DC low consumption","Protective treatment":"TC","Utilisation category":"AC-1 AC-3 AC-4","Contactor application":"Resistive load Motor control","Mechanical durability":"1 Mcycles","Nbr. of units in pkg.":"1","Associated fuse rating":"315 A aM at 400 A BS88 at 400 A gG at <= 440 V","Maximum operating rate":"120 cyc/h 104 °F (40 °C)","Connections - terminals":"lugs-ring terminals 1 0.4 in² (240 mm²) connector 1 0.4 in² (240 mm²) bars 2 32 x 4 mm Power circuit bolted connection","Rated breaking capacity":"2450 A at 220...440 V 2200 A at 500 V 800 A at 1000 V 1700 A at 660/690 V","Product or Component Type":"Magnetic latching contactor","Irms rated making capacity":"2940 A","Power dissipation per pole":"22 W AC-3 39 W AC-1","[Uc] control circuit voltage":"110 V DC","[Ui] rated insulation voltage":"1000 V IEC 60158-1 1000 V IEC 60947-4 1000 V BS 775 1500 V VDE 0110 group C","Control circuit voltage limits":"Latching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"265 A (at 350 A (at 245 A (at <104 °F (40 °C)) at <= 440 V AC AC-4","[Ue] rated operational voltage":"1000 V AC 25...200 Hz","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"5...158 °F (-15...70 °C)","[Icw] rated short-time withstand current":"2200 A 104 °F (40 °C) - 1 s 2200 A 104 °F (40 °C) - 5 s 2200 A 104 °F (40 °C) - 10 s 1230 A 104 °F (40 °C) - 30 s 950 A 104 °F (40 °C) - 1 min 620 A 104 °F (40 °C) - 3 min 480 A 104 °F (40 °C) - 10 min"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2018cc93e7c917baa6db9ded25d897a9.pdf","sourceUrl":"https://www.se.com/ie/en/product/CR1F265FZ7/tesys-f-magnetic-latching-contactor-3p3-no-265-a-110-v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/CR1F265FZ7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the CR1F265FZ7?","answer":"The contactor is rated 265 A in AC-4 duty at ≤ 440 V, with a 110 V DC latching coil. It can switch a 132 kW motor at 400 V AC in AC-4 duty. The rated insulation voltage is 1000 V, and the short-time withstand current is 2200 A for 10 seconds at 40 °C."},{"question":"What is the closest alternative to the CR1F265FZ7 in the TeSys F family?","answer":"Within the TeSys F range, the closest peer would be a standard (non-latching) contactor of the same frame size, such as the LC1F series with a 265 A AC-3 rating. The CR1F265FZ7's distinguishing feature is the magnetic latching coil — it holds position without continuous power, which is useful for battery-backed or energy-saving control circuits. The mounting footprint and power circuit connections are shared across the TeSys F frame, so a swap between latching and non-latching variants would require a coil circuit change, not a panel re-drill."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CR1F265FZ7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CR1F265FZ7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}