{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CR1F265PF7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CR1F265PF7","canonicalUrl":"https://aoctrl.com/schneider/CR1F265PF7","factsUrl":"https://aoctrl.com/api/mcp/products/CR1F265PF7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F magnetic latching contactor, CR1F265PF7, 3-pole (3 NO), 265 A rated operational current, 230 V & 110 V AC/DC coil.","salesMarkdown":"The Schneider CR1F265PF7 is a TeSys F magnetic latching contactor, a 3-pole (3 NO) device rated for 265 A operational current in AC-4 duty, meaning it handles the demanding inrush and plugging cycles of motor reversing or jogging applications. The latching mechanism holds the main contacts closed without continuous coil power — the coil draws 1800 VA only during the latching pulse (40...75 ms), then drops to 12 VA for the unlatching pulse (50...100 ms). This makes it suitable for applications where sustained coil dissipation is undesirable, such as in warm enclosures or on UPS-backed control circuits where every VA counts. The headline rating is 265 A at ≤440 V AC in AC-4, which governs motor reversing and inching duty. For resistive loads (AC-1), the contactor can carry 350 A thermally (Ith) with an average impedance of 0.32 mΩ per pole, so voltage drop across the contacts stays under 0.1 V at full load — relevant for low-voltage-drop circuits like heater banks. Rated insulation voltage is 1000 V per IEC 60947-4, so it can be used on 690 V line-to-line systems with adequate clearance. This is a bolted-contact device, not a DIN-rail snap-on. Power connections accept lugs, ring terminals, or bars — the busbar cross-section can go up to 32 x 4 mm, and the bolted connection torque is 35 N·m. The footprint is 201.5 mm wide by 203 mm high by 213 mm deep, so plan for a backplate or mounting bracket that clears adjacent devices. The control circuit accepts both AC (50...400 Hz) and DC at 230 V or 110 V nominal, with a tolerance band of 0.85...1.1 Uc for both latching and unlatching. That means a 230 V AC coil will reliably pick and drop between 195.5 V and 253 V. ## Protection and coordination For short-circuit coordination, the associated fuse ratings are 315 A aM or 400 A gG at ≤440 V, or 400 A BS88. The rated short-time withstand current (Icw) is 2200 A for 1 second at 40 °C, which gives selectivity headroom for downstream motor starters. ## Environmental limits The protective treatment is TC (tropicalized coating), which resists humidity and mild corrosive atmospheres typical of industrial environments.","metaTitle":"Schneider CR1F265PF7 TeSys F Magnetic Latching Contactor, 26","metaDescription":"Schneider Electric CR1F265PF7 TeSys F magnetic latching contactor, 3P (3 NO), 265 A rated operational current, 132 kW motor power at 400 V AC (AC-4). Active production. Source to o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"213 mm","Range":"TeSys","Width":"201.5 mm","title":"CR1F265PF7","Height":"203 mm","description":"TeSys F magnetic latching contactor - 3P(3 NO)- 265 A - 230 V & 110 V AC/DC coil","Product name":"TeSys F","Motor power kW":"132 kW at 400 V AC 50/60 Hz (AC-4)","Operating time":"40...75 ms latching 50...100 ms unlatching","lifecycle_stage":"current","Average impedance":"0.32 mOhm - Ith 350 A 50 Hz","Device short name":"CR1F","Poles description":"3P","Tightening torque":"35 N.m","Device application":"Control","Operating altitude":"3000 m without derating","Average Consumption":"1800 VA AC 50...400 Hz latching 12 VA AC 50...400 Hz unlatching 1800 VA DC latching 12 VA DC unlatching","Control circuit type":"AC at 50...400 Hz DC standard","Protective treatment":"TC","Utilisation category":"AC-1 AC-3 AC-4","Contactor application":"Resistive load Motor control","Mechanical durability":"1 Mcycles","Associated fuse rating":"315 A aM at 400 A BS88 at 400 A gG at <= 440 V","Maximum operating rate":"120 cyc/h 40 °C","Connections - terminals":"Lugs-ring terminals 1 cable(s) 240 mm² Connector 1 cable(s) 240 mm² Bars 2 cable(s) - busbar cross section: 32 x 4 mm Power circuit: bolted connection","Rated breaking capacity":"2450 A at 220...440 V 2200 A at 500 V 800 A at 1000 V 1700 A at 660/690 V","Product or component type":"Magnetic latching contactor","Irms rated making capacity":"2940 A","Power dissipation per pole":"22 W AC-3 39 W AC-1","[Uc] control circuit voltage":"230 V AC 50...400 Hz 110 V AC 50...400 Hz 230 V DC 110 V DC","[Ui] rated insulation voltage":"1000 V conforming to IEC 60158-1 1000 V conforming to IEC 60947-4 1000 V conforming to BS 775 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Latching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"265 A (at 350 A (at 245 A (at <40 °C) at <= 440 V AC AC-4","[Ue] rated operational voltage":"1000 V AC 25...200 Hz","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-15...70 °C","[Icw] rated short-time withstand current":"2200 A 40 °C - 1 s 2200 A 40 °C - 5 s 2200 A 40 °C - 10 s 1230 A 40 °C - 30 s 950 A 40 °C - 1 min 620 A 40 °C - 3 min 480 A 40 °C - 10 min"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/16b2132cf4249968fb4a878b9715fdad.pdf","sourceUrl":"https://www.se.com/th/en/product/CR1F265PF7/tesys-f-magnetic-latching-contactor-3p3-no-265-a-230-v-110-v-ac-dc-coil/"},"ai":{"faq":[{"question":"What are the key ratings I need to verify for fit?","answer":"The critical ratings are: 265 A operational current in AC-4 at ≤440 V AC, 132 kW motor power at 400 V AC (AC-4), rated insulation voltage 1000 V per IEC 60947-4, and control coil options of 230 V or 110 V AC/DC. The latching coil draws 1800 VA during the 40...75 ms pulse, then 12 VA for the unlatching pulse."},{"question":"What compliance documentation is available for this contactor?","answer":"The contactor carries rated insulation voltage of 1000 V conforming to IEC 60158-1, IEC 60947-4, and BS 775, plus 1500 V conforming to VDE 0110 group C. These standards cover the electrical safety and performance certification typically required for industrial control panels."},{"question":"How do I source this part?","answer":"The CR1F265PF7 is an active-production item sourced to order against an RFQ. Submit a request with your required quantity and target delivery window for a firm quotation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CR1F265PF7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CR1F265PF7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}