{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CR1F4004F7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CR1F4004F7","canonicalUrl":"https://aoctrl.com/schneider/CR1F4004F7","factsUrl":"https://aoctrl.com/api/mcp/products/CR1F4004F7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F magnetic latching contactor, 4P (4 NO), 400 A, 110 V AC/DC coil, AC-4/AC-1/AC-3 utilisation.","salesMarkdown":"The CR1F4004F7 is a TeSys F magnetic latching contactor from Schneider Electric, configured with 4 normally-open power poles and rated for 400 A in AC-4 duty at 40 °C on a 440 V supply. The magnetic latching mechanism holds the contacts closed without continuous coil power — the coil draws 1600 VA during the latching pulse and only 16 VA to unlatch, so it's suited for applications where sustained coil hold-in current is undesirable or where a power loss must not drop the load out. Rated operational voltage goes to 1000 V AC, and the utilisation categories cover AC-1 (resistive), AC-3 (motor starting/running), and AC-4 (plugging/inching). Control circuit voltage is 110 V AC 50...400 Hz or 110 V DC. The 400 A AC-4 rating is the headline figure — this contactor is built for severe switching duty where the motor is reversed or jogged under load, not just started and run. AC-4 imposes higher arcing stress than AC-3, so the 400 A AC-4 rating means it can handle a 400 A motor load in that demanding cycle. For comparison, the same contactor is rated higher in AC-1 (resistive) and AC-3 (standard motor) duty, but the AC-4 number is the one that governs in harsh reversing applications. The rated breaking capacity reaches 4000 A at 220...440 V, and the making capacity is 4500 A — both confirm it can interrupt and close onto fault currents without welding. The short-time withstand current (Icw) is 3600 A for 1 second at 40 °C, giving coordination margin with upstream protection. The contactor measures 8.6 in deep by 10.3 in wide by 8.1 in tall — a substantial footprint that requires panel space and bolted connections. Power circuit terminals accept lugs or ring terminals up to 150 mm², or bars 30 x 5 mm, with a tightening torque of 35 N.m (309.8 lbf.in). The coil is AC/DC compatible (110 V) and draws a 1600 VA pulse to latch, then 16 VA to unlatch — the control circuit must be sized for that inrush. The mechanical durability is rated at 1 million cycles, so it is built for a long service life in a fixed installation.","metaTitle":"CR1F4004F7 TeSys F magnetic latching contactor, 400 A, 110 V","metaDescription":"Schneider Electric TeSys F magnetic latching contactor, 4P (4 NO), 400 A AC-4, 110 V AC/DC coil. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"8.6 in (219 mm)","Range":"TeSys","Width":"10.3 in (261 mm)","Height":"8.1 in (206 mm)","Category":"22336-CTR,F-LINE,AC,OPEN,NONREV","Product name":"TeSys F","Operating time":"40...75 ms latching 50...100 ms unlatching","lifecycle_stage":"current","Average impedance":"0.28 mOhm - Ith 500 A 50 Hz","Device short name":"CR1F","Poles description":"4P","Tightening torque":"309.8 lbf.in (35 N.m)","Device Application":"Control","Operating altitude":"9842.52 ft (3000 m) without derating","Average Consumption":"1600 VA AC 50...400 Hz latching 16 VA AC 50...400 Hz unlatching 1600 VA DC latching 16 VA DC unlatching","Control circuit type":"AC 50...400 Hz DC standard","Protective treatment":"TC","Utilisation category":"AC-4 AC-1 AC-3","Contactor application":"Motor control Resistive load","Mechanical durability":"1 Mcycles","Nbr. of units in pkg.":"1","Associated fuse rating":"400 A aM at 500 A BS88 at 500 A gG at <= 440 V","Maximum operating rate":"120 cyc/h 104 °F (40 °C)","Connections - terminals":"lugs-ring terminals 2 0.2 in² (150 mm²) bars 2 30 x 5 mm Power circuit bolted connection","Rated breaking capacity":"4000 A at 220...440 V 3500 A at 500 V 1200 A at 1000 V 3000 A at 660/690 V","Product or Component Type":"Magnetic latching contactor","Irms rated making capacity":"4500 A","Power dissipation per pole":"45 W AC-3 70 W AC-1","[Uc] control circuit voltage":"110 V AC 50...400 Hz 110 V DC","[Ui] rated insulation voltage":"1000 V IEC 60158-1 1000 V IEC 60947-4 1000 V BS 775 1500 V VDE 0110 group C","Control circuit voltage limits":"Latching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc","Power Pole Contact Composition":"4 NO","[Ie] rated operational current":"400 A (at 500 A (at 370 A (at <104 °F (40 °C)) at <= 440 V AC AC-4","[Ue] rated operational voltage":"1000 V AC 25...200 Hz","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"5...158 °F (-15...70 °C)","[Icw] rated short-time withstand current":"3600 A 104 °F (40 °C) - 1 s 3600 A 104 °F (40 °C) - 5 s 3600 A 104 °F (40 °C) - 10 s 2400 A 104 °F (40 °C) - 30 s 1700 A 104 °F (40 °C) - 1 min 1200 A 104 °F (40 °C) - 3 min 1000 A 104 °F (40 °C) - 10 min"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b977f057aa06a6dafc47f0d8c90604ba.pdf","sourceUrl":"https://www.se.com/th/en/product/CR1F4004F7/tesys-f-magnetic-latching-contactor-4p4-no-400-a-110-v-ac-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/CR1F4004F7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of the CR1F4004F7?","answer":"It is a 4-pole (4 NO) magnetic latching contactor rated 400 A in AC-4 duty at 40 °C, with a control voltage of 110 V AC/DC. Rated operational voltage is 1000 V AC, and it covers utilisation categories AC-1, AC-3, and AC-4."},{"question":"What is the physical size of the CR1F4004F7?","answer":"Dimensions are 8.6 in (219 mm) deep, 10.3 in (261 mm) wide, and 8.1 in (206 mm) high."},{"question":"What is the control circuit voltage and consumption?","answer":"The coil is rated 110 V AC 50...400 Hz or 110 V DC. Latching consumption is 1600 VA (AC or DC), and unlatching consumption is 16 VA (AC or DC)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CR1F4004F7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CR1F4004F7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}