{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CR1F400PF7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CR1F400PF7","canonicalUrl":"https://aoctrl.com/schneider/CR1F400PF7","factsUrl":"https://aoctrl.com/api/mcp/products/CR1F400PF7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F CR1F400PF7, magnetic latching contactor, 3P (3 NO), 400 A, 200 kW at 400 V AC (AC-4), 230/110 V AC/DC coil, bolted connection.","salesMarkdown":"The CR1F400PF7 is a TeSys F magnetic latching contactor from Schneider Electric — a 3-pole (3 NO) device rated for 400 A operational current and capable of switching a 200 kW motor at 400 V AC under AC-4 duty, the most demanding category for plugging and inching. The magnetic latching mechanism holds the main poles closed without continuous coil power, so the coil only draws current during the latching and unlatching transitions — 1600 VA for 40–75 ms to latch, 16 VA for 50–100 ms to unlatch. The coil accepts dual control voltages — 230 V or 110 V, both AC 50–400 Hz and DC — giving flexibility across different control circuits without changing the contactor. The rated insulation voltage is 1000 V per IEC 60947-4, and the operational voltage goes up to 1000 V AC. It is built for motor control and resistive loads, with utilisation categories AC-3 (squirrel-cage motors: starting, switching off running motors), AC-1 (resistive loads), and AC-4 (plugging, inching, reversing). The headline 400 A rated operational current (Ie) is the continuous current the main poles carry in free air at ≤40 °C. Under AC-4, that figure drops to 370 A at <40 °C and ≤440 V — the duty cycle matters. The motor power rating of 200 kW at 400 V AC-4 tells you the heaviest motor load this contactor can handle under reversing or inching duty. For AC-3 (normal starting/running), the same contactor handles higher currents, but the evidence does not give that specific figure — the AC-4 number is the conservative bound. The short-time withstand current (Icw) is 3600 A for 1, 5, and 10 seconds at 40 °C — that is the fault current the contactor can carry without welding or damage until an upstream protective device clears. The rated breaking capacity reaches 4000 A at 220–440 V, 3500 A at 500 V, and 3000 A at 660/690 V. Associated fuse ratings are 400 A aM or gG at ≤440 V, or 500 A BS88. These numbers govern coordination with upstream fuses or circuit breakers. Power dissipation per pole runs 45 W under AC-3 and 70 W under AC-1 — relevant for enclosure thermal design. The contactor operates from -15 °C to 70 °C ambient and stores from -60 °C to 80 °C. ## Physical integration and connections The CR1F400PF7 measures 219 mm deep, 213 mm wide, and 206 mm tall — a substantial frame for a 400 A contactor. Power connections are bolted, accepting lugs or ring terminals for up to two 150 mm² cables per pole, or bars with a busbar cross-section of 30 x 5 mm. Tightening torque is 35 N·m. This is a panel-mount device, not DIN-rail; it bolts directly to a backplate or mounting bracket.","metaTitle":"Schneider CR1F400PF7 TeSys F Magnetic Latching Contactor, 40","metaDescription":"Obsolete TeSys F magnetic latching contactor, 3P, 400 A, 200 kW at 400 V AC-4. 230/110 V AC/DC coil. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"219 mm","Range":"TeSys","Width":"213 mm","Height":"206 mm","Product name":"TeSys F","Motor power kW":"200 kW at 400 V AC 50/60 Hz (AC-4)","Operating time":"40...75 ms latching 50...100 ms unlatching","lifecycle_stage":"current","Average impedance":"0.28 mOhm - Ith 500 A 50 Hz","Device short name":"CR1F","Poles description":"3P","Tightening torque":"35 N.m","Device application":"Control","Operating altitude":"3000 m without derating","Average Consumption":"1600 VA AC 50...400 Hz latching 16 VA AC 50...400 Hz unlatching 1600 VA DC latching 16 VA DC unlatching","Protective treatment":"TC","Utilisation category":"AC-3 AC-1 AC-4","Contactor application":"Motor control Resistive load","Mechanical durability":"1 Mcycles","Associated fuse rating":"400 A aM at 500 A BS88 at 500 A gG at <= 440 V","Maximum operating rate":"120 cyc/h 40 °C","Connections - terminals":"Lugs-ring terminals 2 cable(s) 150 mm² Bars 2 cable(s) - busbar cross section: 30 x 5 mm Power circuit: bolted connection","Rated breaking capacity":"4000 A at 220...440 V 3500 A at 500 V 1200 A at 1000 V 3000 A at 660/690 V","Product or component type":"Magnetic latching contactor","Irms rated making capacity":"4500 A","Power dissipation per pole":"45 W AC-3 70 W AC-1","[Uc] control circuit voltage":"230 V AC 50...400 Hz 110 V AC 50...400 Hz 230 V DC 110 V DC","[Ui] rated insulation voltage":"1000 V conforming to IEC 60158-1 1000 V conforming to IEC 60947-4 1000 V conforming to BS 775 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Latching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"400 A (at 500 A (at 370 A (at <40 °C) at <= 440 V AC AC-4","[Ue] rated operational voltage":"1000 V AC 25...200 Hz","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-15...70 °C","[Icw] rated short-time withstand current":"3600 A 40 °C - 1 s 3600 A 40 °C - 5 s 3600 A 40 °C - 10 s 2400 A 40 °C - 30 s 1700 A 40 °C - 1 min 1200 A 40 °C - 3 min 1000 A 40 °C - 10 min"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/07086576ad3af6834579bcb53135700b.pdf","sourceUrl":"https://www.se.com/sg/en/product/CR1F400PF7/tesys-f-magnetic-latching-contactor-3p3-no-400-a-230-v-110-v-ac-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/CR1F400PF7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the CR1F400PF7?","answer":"It is a 3-pole magnetic latching contactor rated 400 A operational current, 200 kW at 400 V AC under AC-4 duty, with a 230/110 V AC/DC coil. The rated insulation voltage is 1000 V per IEC 60947-4, and the short-time withstand current is 3600 A for 1 second."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CR1F400PF7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CR1F400PF7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}