{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CR1F5004N7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CR1F5004N7","canonicalUrl":"https://aoctrl.com/schneider/CR1F5004N7","factsUrl":"https://aoctrl.com/api/mcp/products/CR1F5004N7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F CR1F5004N7, magnetic latching contactor, 4-pole, 500 A rated operational current, 415 V AC 50/60 Hz coil, 335 kW motor power at 690 V.","salesMarkdown":"## Magnetic Latching Contactor for Heavy Motor Control The Schneider Electric CR1F5004N7 is a TeSys F magnetic latching contactor with 4 normally open power poles, rated for 500 A operational current (AC-3 duty) and capable of switching motor loads up to 335 kW at 690 V AC 50/60 Hz. The magnetic latching mechanism holds the contacts closed without continuous coil power — the 415 V AC coil draws 1800 VA during the latching pulse, then only 13 VA for unlatching. This makes it suited for applications where sustained coil power is undesirable or where a power loss must not drop out the load. The 500 A rating at <= 440 V AC under AC-4 category means this contactor handles the severe inrush and plugging duty of reversing or jogging motor loads — not just steady running. Mechanical durability is 1 Mcycles, reflecting the robust TeSys F frame. ## Where It Belongs in the Panel Mounts on a notched AM1-EC rail — the standard heavy-duty DIN rail for contactors this size. Front face carries IP20 protection per IEC 60529, so it's touch-safe in an enclosed panel but not for open washdown areas. Connections accept lugs, ring terminals up to 240 mm², or bars 40 x 5 mm, torqued to 309.8 lbf.in (35 N.m). The 9.1 in (232 mm) depth and 11.3 in (288 mm) width require generous cabinet space; plan for side clearance for arc-chamber venting and cable bending radius.","metaTitle":"Schneider TeSys F CR1F5004N7 Magnetic Latching Contactor, 50","metaDescription":"Schneider Electric CR1F5004N7 TeSys F magnetic latching contactor. 500 A rated operational current, 335 kW motor power at 690 V. 4-pole, 415 V AC coil. IEC 60947-4. Current lifecyc","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"9.1 in (232 mm)","Range":"TeSys","Width":"11.3 in (288 mm)","Height":"9.4 in (238 mm)","Category":"22336-CTR,F-LINE,AC,OPEN,NONREV","Standards":"IEC 60947-4 NF C 63-110 BS 5424 VDE 0660 JEM 1038","Product name":"TeSys F","Motor power kW":"335 kW at 1000 V AC 50/60 Hz 335 kW at 690 V AC 50/60 Hz 335 kW at 500...660 V AC 50/60 Hz 295 kW at 440 V AC 50/60 Hz 280 kW at 415 V AC 50/60 Hz 250 kW at 380...400 V AC 50/60 Hz 147 kW at 220...230 V AC 50/60 Hz","Operating time":"40...80 ms latching 50...100 ms unlatching","lifecycle_stage":"current","Mounting Support":"Notched AM1-EC rail","Average impedance":"0.18 mOhm - Ith 700 A 50 Hz","Device short name":"CR1F","Poles description":"4P","Tightening torque":"309.8 lbf.in (35 N.m)","Device Application":"Control","Operating altitude":"9842.52 ft (3000 m) without derating","Average Consumption":"1800 VA AC 50...400 Hz latching 13 VA AC 50...400 Hz unlatching 1800 VA DC latching 13 VA DC unlatching","Protective treatment":"TH","Utilisation category":"AC-4 AC-1 AC-3","Contactor application":"Resistive load Motor control","Mechanical durability":"1 Mcycles","Nbr. of units in pkg.":"1","Associated fuse rating":"500 A aM at 800 A BS88 at 800 A gG at <= 440 V for power circuit","Maximum operating rate":"120 cyc/h 104 °F (40 °C)","Connections - terminals":"lugs-ring terminals 2 0.4 in² (240 mm²) bars 2 40 x 5 mm","IP degree of protection":"IP20 front face IEC 60529","Rated breaking capacity":"5000 A at 220...440 V for power circuit 4500 A at 500 V for power circuit 2500 A at 1000 V for power circuit 3560 A at 660/690 V for power circuit","Product or Component Type":"Magnetic latching contactor","motor power HP (UL / CSA)":"500 hp at 575...600 V AC 50/60 Hz for 3 phase motors 400 hp at 460...480 V AC 50/60 Hz for 3 phase motors 200 hp at 220...240 V AC 50/60 Hz for 3 phase motors 150 hp at 200...208 V AC 50/60 Hz for 3 phase motors","Irms rated making capacity":"5000 A for power circuit","Power dissipation per pole":"45 W AC-3 88 W AC-1","[Uc] control circuit voltage":"415 V AC 50/60 Hz","[Ui] rated insulation voltage":"1000 V IEC 60158-1 1000 V IEC 60947-4 1000 V BS 775 1500 V VDE 0110 group C","Control circuit voltage limits":"Latching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc","Power Pole Contact Composition":"4 NO","[Ie] rated operational current":"500 A (at 700 A (at 460 A (at <104 °F (40 °C)) at <= 440 V AC AC-4","[Ue] rated operational voltage":"1000 V AC 25...200 Hz","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"5...158 °F (-15...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"4200 A 104 °F (40 °C) - 1 s 4200 A 104 °F (40 °C) - 5 s 4200 A 104 °F (40 °C) - 10 s 3200 A 104 °F (40 °C) - 30 s 2400 A 104 °F (40 °C) - 1 min 1500 A 104 °F (40 °C) - 3 min 1200 A 104 °F (40 °C) - 10 min","[Ith] conventional free air thermal current":"700 A (at 104 °F (40 °C)) for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cd390e1ccdbe7add5f8e6983048a5a8f.pdf","sourceUrl":"https://www.se.com/th/en/product/CR1F5004N7/bistable-contactor-cr1f-4p-ac1-440v-700-a-coil-415-v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/CR1F5004N7/alternatives.json"},"ai":{"faq":[{"question":"What is the control voltage for this contactor?","answer":"The control circuit voltage is 415 V AC 50/60 Hz. Latching and unlatching both operate within 0.85...1.1 Uc limits."},{"question":"What standards does the CR1F5004N7 comply with?","answer":"It complies with IEC 60947-4, NF C 63-110, BS 5424, VDE 0660, and JEM 1038. Rated insulation voltage is 1000 V per IEC 60947-4 and VDE 0110 group C."},{"question":"What is the breaking capacity?","answer":"Rated breaking capacity is 5000 A at 220...440 V, 4500 A at 500 V, 3560 A at 660/690 V, and 2500 A at 1000 V for the power circuit."},{"question":"What is the closest alternative in the TeSys F family?","answer":"Within the TeSys F range, variants differ by coil voltage and pole configuration. The CR1F5004N7 uses a 415 V AC coil and 4 NO poles. A unit with a different coil voltage (e.g., 110 V or 230 V) or a different pole count (3-pole) would be a different order code. Select based on your control voltage and number of switched phases."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CR1F5004N7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CR1F5004N7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}