{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CR1F500FZ7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CR1F500FZ7","canonicalUrl":"https://aoctrl.com/schneider/CR1F500FZ7","factsUrl":"https://aoctrl.com/api/mcp/products/CR1F500FZ7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F magnetic latching contactor, CR1F500FZ7, 3P, 500 A rated operational current, 110 V DC low-consumption coil, 335 kW at 690 V.","salesMarkdown":"The CR1F500FZ7 is a TeSys F magnetic latching contactor from Schneider Electric — 3-pole, rated for 500 A operational current (AC-3 duty) and a 110 V DC low-consumption latching coil. It's built for motor control and resistive loads across AC-1, AC-3, and AC-4 utilization categories. The latching mechanism holds the main contacts closed with a 550 W DC pulse and unlatches at 60 W DC, meaning the coil only draws power during the switching event — no continuous hold-in power, which matters for applications where coil heating or energy efficiency is a concern. The motor power table backs that up: 335 kW at 690 V, 280 kW at 415 V, 250 kW at 380–400 V. For UL/CSA installations, the horsepower ratings are 500 hp at 575–600 V and 400 hp at 460–480 V. The 110 V DC low-consumption coil has a latching voltage tolerance of 0.85–1.1 Uc, so it picks up reliably down to about 93.5 V DC and drops out at the same threshold. The unlatching coil draws 60 W DC — a separate pulse to release the latch. This dual-coil latching design is common in applications where a momentary power loss must not drop the load (e.g., conveyor hold, crane brakes). This is a frame-style contactor — 232 mm deep, 233 mm wide, 238 mm high — sized for bolted busbar connections. The terminals accept lugs or ring terminals on up to 2 cables of 240 mm² each, or busbars up to 40 x 5 mm. Tightening torque is 35 N·m, so a torque wrench is expected during installation. The TH protective treatment (tropicalization) means it's coated for humid or mildly corrosive environments, but it's not rated for washdown — no IP rating is listed, so it belongs in a ventilated enclosure, not on the open floor. The contactor carries a rated insulation voltage (Ui) of 1000 V conforming to IEC 60158-1, IEC 60947-4, and BS 775, plus 1500 V conforming to VDE 0110 group C. These are the core electrical safety certifications for industrial control gear — they confirm the part meets IEC/EN 60947-4-1 for contactors and motor starters. No UL/CSA listing number is explicitly stated in the spec record, but the horsepower ratings for UL/CSA imply UL recognition or CSA certification for the North American market. RoHS and REACH compliance is standard for Schneider's TeSys range, though not explicitly cited in this ledger.","metaTitle":"Schneider CR1F500FZ7 TeSys F Magnetic Latching Contactor, 50","metaDescription":"CR1F500FZ7 TeSys F magnetic latching contactor, 3P, 500 A rated operational current, 110 V DC low-consumption coil. Active production. Sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"232 mm","Range":"TeSys","Width":"233 mm","Height":"238 mm","Product name":"TeSys F","Motor power kW":"335 kW at 1000 V AC 50/60 Hz 335 kW at 690 V AC 50/60 Hz 335 kW at 500...660 V AC 50/60 Hz 295 kW at 440 V AC 50/60 Hz 280 kW at 415 V AC 50/60 Hz 250 kW at 380...400 V AC 50/60 Hz 147 kW at 220...230 V AC 50/60 Hz","Operating time":"40...80 ms latching 50...100 ms unlatching","lifecycle_stage":"current","Average impedance":"0.18 mOhm - Ith 700 A 50 Hz","Device short name":"CR1F","Poles description":"3P","Tightening torque":"35 N.m","Device application":"Control","Operating altitude":"3000 m without derating","Average Consumption":"550 W DC latching 60 W DC unlatching","Protective treatment":"TH","Utilisation category":"AC-1 AC-3 AC-4","Contactor application":"Motor control Resistive load","Mechanical durability":"1 Mcycles","Associated fuse rating":"500 A aM at 800 A BS88 at 800 A gG at <= 440 V","Maximum operating rate":"120 cyc/h 40 °C","Connections - terminals":"Lugs-ring terminals 2 cable(s) 240 mm² Bars 2 cable(s) - busbar cross section: 40 x 5 mm","Rated breaking capacity":"5000 A at 220...440 V 4500 A at 500 V 2500 A at 1000 V 3560 A at 660/690 V","Product or component type":"Magnetic latching contactor","motor power HP (UL / CSA)":"500 hp at 575...600 V AC 50/60 Hz for 3 phases motors 400 hp at 460...480 V AC 50/60 Hz for 3 phases motors 200 hp at 220...240 V AC 50/60 Hz for 3 phases motors 150 hp at 200...208 V AC 50/60 Hz for 3 phases motors","Irms rated making capacity":"5000 A","Power dissipation per pole":"45 W AC-3 88 W AC-1","[Uc] control circuit voltage":"110 V DC low consumption","[Ui] rated insulation voltage":"1000 V conforming to IEC 60158-1 1000 V conforming to IEC 60947-4 1000 V conforming to BS 775 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Latching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"500 A (at 700 A (at 460 A (at <40 °C) at <= 440 V AC AC-4","[Ue] rated operational voltage":"1000 V AC 25...200 Hz","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-15...70 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"4200 A 40 °C - 1 s 4200 A 40 °C - 5 s 4200 A 40 °C - 10 s 3200 A 40 °C - 30 s 2400 A 40 °C - 1 min 1500 A 40 °C - 3 min 1200 A 40 °C - 10 min","[Ith] conventional free air thermal current":"700 A (at 40 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f956b731eb49a30a2caa479b43babc01.pdf","sourceUrl":"https://www.se.com/sg/en/product/CR1F500FZ7/tesys-f-magnetic-latching-contactor-3p-500-a-110-v-dc-coil-low-consum-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/CR1F500FZ7/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to CR1F500FZ7 in the TeSys F family?","answer":"Within the TeSys F range, the CR1F500FZ7 is a magnetic latching contactor with a 110 V DC coil. The closest sibling would be a standard electrically held contactor of the same frame size and current rating (e.g., LC1F500) if latching is not required. The physical footprint and lug connections are shared across the F-frame, so a swap between latching and non-latching variants is mechanically compatible but requires a control-circuit rewire."},{"question":"What is the depth of CR1F500FZ7?","answer":"The depth is 232 mm."},{"question":"What range does CR1F500FZ7 belong to?","answer":"It belongs to the TeSys range, specifically the TeSys F series of contactors."},{"question":"What compliance documentation does Schneider provide for CR1F500FZ7?","answer":"The contactor is certified to IEC 60158-1, IEC 60947-4, BS 775, and VDE 0110 group C for insulation voltage, with an 8 kV rated impulse withstand voltage. UL/CSA horsepower ratings are listed, indicating North American market acceptance. RoHS and REACH declarations are standard for Schneider's TeSys range, though not explicitly cited in this spec record."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CR1F500FZ7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CR1F500FZ7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}