{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CR1F500N7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CR1F500N7","canonicalUrl":"https://aoctrl.com/schneider/CR1F500N7","factsUrl":"https://aoctrl.com/api/mcp/products/CR1F500N7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F series, CR1F500N7, magnetic latching contactor, 3-pole, 500 A rated operational current (AC-4), 335 kW at 690 V AC, 415 V AC control.","salesMarkdown":"It's rated for motor control and resistive loads across utilisation categories AC-1, AC-3, and AC-4. The headline rating is 500 A in AC-4 duty at ≤440 V (the severest category, for plugging and inching of motors), with a 700 A rating in AC-3 at the same voltage. That translates to 335 kW at 690 V AC or 280 kW at 400 V AC, which covers large pumps, compressors, or conveyor drives on a 690 V industrial network. The AC-4 current of 500 A is the number that governs the real-world switching of reversing or jogging motor loads — the heavier the duty cycle, the more this rating matters over the AC-3 figure. For resistive loads (AC-1), the contactor is rated at 700 A Ith, with a power dissipation of 88 W per pole under that load. The control circuit is 415 V AC 50/60 Hz, with a latching coil draw of 1800 VA and unlatching at 13 VA. The operating time is 40–80 ms to latch, 50–100 ms to unlatch. That latching pulse is brief but substantial — the coil supply needs to handle that inrush without sag. The associated fuse recommendation is 500 A aM or 800 A gG/gG-type up to 440 V. This is a panel-mount contactor sized for a notched AM1-EC rail — the mounting support is specific, not a standard DIN rail. At 9.1 in deep, 9.2 in wide, and 9.4 in tall, it needs a generous enclosure. The terminals accept lugs or ring terminals up to 240 mm², or bars 40 x 5 mm, torqued to 35 N·m. The CR1F500N7 carries compliance with IEC 60947-4, JEM 1038, VDE 0660, BS 5424, and NF C 63-110. Rated insulation voltage is 1000 V per IEC 60947-4 and 1500 V per VDE 0110 Group C. The protective treatment is TH (tropicalised) for humid environments.","metaTitle":"Schneider Electric CR1F500N7 TeSys F Magnetic Latching Conta","metaDescription":"Schneider Electric CR1F500N7 TeSys F magnetic latching contactor, 3-pole, 500 A rated operational current in AC-4, 335 kW at 690 V. Current production. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"9.1 in (232 mm)","Range":"TeSys","Width":"9.2 in (233 mm)","title":"CR1F500N7","Height":"9.4 in (238 mm)","Category":"22336-CTR,F-LINE,AC,OPEN,NONREV","Standards":"IEC 60947-4 JEM 1038 VDE 0660 BS 5424 NF C 63-110","description":"Bistable contactor CR1-F - 3P - AC-3 440V 500 A - coil 415 V","Product name":"TeSys F","Motor power kW":"335 kW at 1000 V AC 50/60 Hz 335 kW at 690 V AC 50/60 Hz 335 kW at 500...660 V AC 50/60 Hz 295 kW at 440 V AC 50/60 Hz 280 kW at 415 V AC 50/60 Hz 250 kW at 380...400 V AC 50/60 Hz 147 kW at 220...230 V AC 50/60 Hz","Operating time":"40...80 ms latching 50...100 ms unlatching","lifecycle_stage":"current","Mounting Support":"Notched AM1-EC rail","Average impedance":"0.18 mOhm - Ith 700 A 50 Hz","Device short name":"CR1F","Poles description":"3P","Tightening torque":"309.8 lbf.in (35 N.m)","Device Application":"Control","Operating altitude":"9842.52 ft (3000 m) without derating","Average Consumption":"1800 VA AC 50...400 Hz latching 13 VA AC 50...400 Hz unlatching 1800 VA DC latching 13 VA DC unlatching","Protective treatment":"TH","Utilisation category":"AC-4 AC-3 AC-1","Contactor application":"Motor control Resistive load","Mechanical durability":"1 Mcycles","Nbr. of units in pkg.":"1","Associated fuse rating":"500 A aM at 800 A BS88 at 800 A gG at <= 440 V for power circuit","Maximum operating rate":"120 cyc/h 104 °F (40 °C)","Connections - terminals":"lugs-ring terminals 2 0.4 in² (240 mm²) bars 2 40 x 5 mm","IP degree of protection":"IP20 front face IEC 60529","Rated breaking capacity":"5000 A at 220...440 V for power circuit 4500 A at 500 V for power circuit 2500 A at 1000 V for power circuit 3560 A at 660/690 V for power circuit","Product or Component Type":"Magnetic latching contactor","motor power HP (UL / CSA)":"500 hp at 575...600 V AC 50/60 Hz for 3 phase motors 400 hp at 460...480 V AC 50/60 Hz for 3 phase motors 200 hp at 220...240 V AC 50/60 Hz for 3 phase motors 150 hp at 200...208 V AC 50/60 Hz for 3 phase motors","Irms rated making capacity":"5000 A for power circuit","Power dissipation per pole":"45 W AC-3 88 W AC-1","[Uc] control circuit voltage":"415 V AC 50/60 Hz","[Ui] rated insulation voltage":"1000 V IEC 60158-1 1000 V IEC 60947-4 1000 V BS 775 1500 V VDE 0110 group C","Control circuit voltage limits":"Latching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"500 A (at 700 A (at 460 A (at <104 °F (40 °C)) at <= 440 V AC AC-4","[Ue] rated operational voltage":"1000 V AC 25...200 Hz","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"5...158 °F (-15...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"4200 A 104 °F (40 °C) - 1 s 4200 A 104 °F (40 °C) - 5 s 4200 A 104 °F (40 °C) - 10 s 3200 A 104 °F (40 °C) - 30 s 2400 A 104 °F (40 °C) - 1 min 1500 A 104 °F (40 °C) - 3 min 1200 A 104 °F (40 °C) - 10 min","[Ith] conventional free air thermal current":"700 A (at 104 °F (40 °C)) for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/52c2e850cd9e86b5089744ddadbc9f00.pdf","sourceUrl":"https://www.se.com/sg/en/product/CR1F500N7/bistable-contactor-cr1f-3p-ac3-440v-500-a-coil-415-v/"},"ai":{"faq":[{"question":"What are the key motor power ratings for the CR1F500N7?","answer":"At 690 V AC three-phase, it handles 335 kW; at 400 V AC, 250 kW; at 230 V AC, 147 kW. UL/CSA ratings are 500 hp at 575–600 V and 400 hp at 460–480 V."},{"question":"What compliance standards does the CR1F500N7 meet?","answer":"It complies with IEC 60947-4, JEM 1038, VDE 0660, BS 5424, and NF C 63-110. Rated insulation voltage is 1000 V per IEC 60947-4."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CR1F500N7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CR1F500N7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}