{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CR1F500Q7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CR1F500Q7","canonicalUrl":"https://aoctrl.com/schneider/CR1F500Q7","factsUrl":"https://aoctrl.com/api/mcp/products/CR1F500Q7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F CR1F500Q7, magnetic latching contactor, 3-pole, 500 A rated operational current, 335 kW motor power at 690 V AC, 380-400 V AC 50/60 Hz coil.","salesMarkdown":"The Schneider CR1F500Q7 is a TeSys F magnetic latching contactor — a 3-pole device that uses a pulse on the coil to latch closed and a separate pulse to unlatch, so it holds its state without continuous coil power. That makes it the right choice for applications where you want to avoid coil heating or need the contactor to stay closed through a control-power dip. It's rated for motor control (AC-3, AC-4) and resistive loads (AC-1), with a rated operational current of 500 A in AC-4 duty at 440 V. The coil is wound for 380-400 V AC 50/60 Hz, and the latching coil draws 1800 VA while the unlatching coil draws 13 VA — a big difference that matters when sizing the control transformer or pulse capacitors. Operating time is 40-80 ms to latch, 50-100 ms to unlatch. The rated operational current of 500 A in AC-4 (the toughest motor starting category, with inrush and plugging) tells you this contactor handles heavy reversing or jogging duty. In AC-3 (normal start-run), the current rating is higher — 700 A at 440 V — so it comfortably covers a 335 kW motor at 690 V or a 250 kW motor at 400 V. The motor power table covers voltages from 220 V to 1000 V, so you can match it to the line voltage without recalculating. The associated fuse recommendation is 500 A aM or 800 A gG — that's the upstream protection the contactor expects to coordinate with. Power dissipation per pole is 45 W in AC-3 and 88 W in AC-1 — that's the heat you need to vent from the enclosure. At 120 cycles per hour maximum operating rate, it's not a high-speed switching device; it's built for sustained motor duty. Certified to EN/IEC 60947-1, EN/IEC 60947-4-1, JIS C8201-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. That covers the main industrial control standards for Europe, Japan, North America, and Canada. The rated insulation voltage is 1000 V per IEC and BS, 1500 V per VDE 0110 group C.","metaTitle":"Schneider CR1F500Q7 TeSys F Magnetic Latching Contactor, 500","metaDescription":"Schneider CR1F500Q7 TeSys F magnetic latching contactor, 3-pole, 500 A rated operational current, 335 kW motor power at 690 V. Current lifecycle stage. UL/CSA/IEC certified.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"9.1 in (232 mm)","Range":"TeSys","Width":"9.2 in (233 mm)","Height":"9.4 in (238 mm)","Category":"22336-CTR,F-LINE,AC,OPEN,NONREV","Standards":"EN/IEC 60947-1 EN/IEC 60947-4-1 JIS C8201-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1","Product name":"TeSys F","Motor power kW":"335 kW at 1000 V AC 50/60 Hz 335 kW at 690 V AC 50/60 Hz 335 kW at 500...660 V AC 50/60 Hz 295 kW at 440 V AC 50/60 Hz 280 kW at 415 V AC 50/60 Hz 250 kW at 380...400 V AC 50/60 Hz 147 kW at 220...230 V AC 50/60 Hz","Operating time":"40...80 ms latching 50...100 ms unlatching","lifecycle_stage":"current","Mounting Support":"Notched AM1-EC rail","Average impedance":"0.18 mOhm - Ith 700 A 50 Hz","Device short name":"CR1F","Poles description":"3P","Tightening torque":"309.8 lbf.in (35 N.m)","Device Application":"Control","Operating altitude":"9842.52 ft (3000 m) without derating","Average Consumption":"1800 VA AC 50...400 Hz latching 13 VA AC 50...400 Hz unlatching 1800 VA DC latching 13 VA DC unlatching","Protective treatment":"TH","Utilisation category":"AC-3 AC-1 AC-4","Contactor application":"Motor control Resistive load","Mechanical durability":"1 Mcycles","Nbr. of units in pkg.":"1","Associated fuse rating":"500 A aM at 800 A BS88 at 800 A gG at <= 440 V for power circuit","Maximum operating rate":"120 cyc/h 104 °F (40 °C)","Connections - terminals":"lugs-ring terminals 2 0.4 in² (240 mm²) bars 2 40 x 5 mm","IP degree of protection":"IP20 front face IEC 60529","Rated breaking capacity":"5000 A at 220...440 V for power circuit 4500 A at 500 V for power circuit 2500 A at 1000 V for power circuit 3560 A at 660/690 V for power circuit","Product or Component Type":"Magnetic latching contactor","motor power HP (UL / CSA)":"500 hp at 575...600 V AC 50/60 Hz for 3 phase motors 400 hp at 460...480 V AC 50/60 Hz for 3 phase motors 200 hp at 220...240 V AC 50/60 Hz for 3 phase motors 150 hp at 200...208 V AC 50/60 Hz for 3 phase motors","Irms rated making capacity":"5000 A for power circuit","Power dissipation per pole":"45 W AC-3 88 W AC-1","[Uc] control circuit voltage":"380...400 V AC 50/60 Hz","[Ui] rated insulation voltage":"1000 V IEC 60158-1 1000 V IEC 60947-4 1000 V BS 775 1500 V VDE 0110 group C","Control circuit voltage limits":"Latching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"500 A (at 700 A (at 460 A (at <104 °F (40 °C)) at <= 440 V AC AC-4","[Ue] rated operational voltage":"1000 V AC 25...200 Hz","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"5...158 °F (-15...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"4200 A 104 °F (40 °C) - 1 s 4200 A 104 °F (40 °C) - 5 s 4200 A 104 °F (40 °C) - 10 s 3200 A 104 °F (40 °C) - 30 s 2400 A 104 °F (40 °C) - 1 min 1500 A 104 °F (40 °C) - 3 min 1200 A 104 °F (40 °C) - 10 min","[Ith] conventional free air thermal current":"700 A (at 104 °F (40 °C)) for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c80686265e3a1dbc5646dad51afda3cc.pdf","sourceUrl":"https://www.se.com/sg/en/product/CR1F500Q7/bistable-contactor-cr1f-3p-ac3-440v-500-a-coil-380-400-v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/CR1F500Q7/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does Schneider provide for CR1F500Q7?","answer":"The contactor carries UL, CSA, IEC, and JIS certifications as listed on the nameplate. Standard Schneider documentation includes the declaration of conformity to the applicable directives and the product datasheet with full specifications."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CR1F500Q7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CR1F500Q7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}