{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CR1F6304E7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CR1F6304E7","canonicalUrl":"https://aoctrl.com/schneider/CR1F6304E7","factsUrl":"https://aoctrl.com/api/mcp/products/CR1F6304E7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F series, magnetic latching contactor, CR1F6304E7, 4 NO poles, 630 A rated operational current, 48 V AC/DC control circuit.","salesMarkdown":"Rated operational current is 630 A, and the contactor handles motor loads across a wide voltage range: 450 kW at 690 V AC, 400 kW at 440 V AC, 335 kW at 380-400 V AC, and 200 kW at 220-230 V AC, all at 50/60 Hz. For UL/CSA applications, the motor power ratings are 800 hp at 575-600 V AC, 600 hp at 460-480 V AC, 300 hp at 220-240 V AC, and 250 hp at 200-208 V AC for three-phase motors. The 630 A rating in AC-3 duty means this contactor is sized for heavy motor switching — starting and stopping induction motors under load. Control circuit voltage is 48 V AC (50-400 Hz) or 48 V DC, with latching and unlatching limits of 0.85 to 1.1 times Uc. That means the coil must see at least 40.8 V and no more than 52.8 V to reliably latch or drop out — a tight window, so verify your control transformer regulation. Rated breaking capacity is 6300 A at 220-440 V, tapering to 3200 A at 1000 V for the power circuit. That gives selectivity headroom downstream — the contactor clears faults up to those levels without welding, provided upstream protection is coordinated. That's suitable for process lines with moderate cycling, not high-speed pick-and-place applications. Mounts on a notched AM1-EC rail — a dedicated mounting plate, not a standard DIN rail — so plan for panel space accordingly. The contactor is 15.3 inches wide, 12.0 inches tall, and 10.04 inches deep, with bar-type terminals accepting two 60 x 5 mm bars per pole. The contactor complies with IEC 60947-4, BS 5424, VDE 0660, NF C 63-110, and JEM 1038 standards. Associated fuse rating is 630 A aM or gG at up to 440 V for the power circuit.","metaTitle":"Schneider TeSys F CR1F6304E7 Magnetic Latching Contactor, 63","metaDescription":"Schneider Electric TeSys F CR1F6304E7 magnetic latching contactor. 630 A rated operational current, 4 NO poles, 48 V AC/DC coil. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"10.04 in (255 mm)","Range":"TeSys","Width":"15.3 in (389 mm)","title":"CR1F6304E7","Height":"12.0 in (304 mm)","Category":"22331-CTR,F-LINE,DC,OPEN,NONREV","Standards":"IEC 60947-4 BS 5424 VDE 0660 NF C 63-110 JEM 1038","description":"Bistable contactor CR1-F - 4P - AC-1 440V 1000 A - coil 48 V","Product name":"TeSys F","Motor power kW":"450 kW at 1000 V AC 50/60 Hz 450 kW at 690 V AC 50/60 Hz 400 kW at 500...660 V AC 50/60 Hz 400 kW at 440 V AC 50/60 Hz 375 kW at 415 V AC 50/60 Hz 335 kW at 380...400 V AC 50/60 Hz 200 kW at 220...230 V AC 50/60 Hz","Operating time":"40...80 ms latching 50...100 ms unlatching","lifecycle_stage":"current","Mounting Support":"Notched AM1-EC rail","Average impedance":"0.12 mOhm - Ith 1000 A 50 Hz","Device short name":"CR1F","Poles description":"4P","Tightening torque":"513.3 lbf.in (58 N.m)","Device Application":"Control","Operating altitude":"9842.52 ft (3000 m) without derating","Average Consumption":"11 VA AC 50...400 Hz unlatching 2300 VA AC 50...400 Hz latching 11 VA DC unlatching 2300 VA DC latching","Protective treatment":"TH","Utilisation category":"AC-3 AC-1 AC-4","Contactor application":"Resistive load Motor control","Mechanical durability":"1 Mcycles","Nbr. of units in pkg.":"1","Associated fuse rating":"630 A aM at 1000 A BS88 at 1000 A gG at <= 440 V for power circuit","Maximum operating rate":"120 cyc/h 104 °F (40 °C)","Connections - terminals":"bars 2 60 x 5 mm","IP degree of protection":"IP20 front face IEC 60529","Rated breaking capacity":"3200 A at 1000 V 6300 A at 220...440 V for power circuit 5400 A at 500 V for power circuit 4600 A at 660/690 V for power circuit","Product or Component Type":"Magnetic latching contactor","motor power HP (UL / CSA)":"800 hp at 575...600 V AC 50/60 Hz for 3 phase motors 600 hp at 460...480 V AC 50/60 Hz for 3 phase motors 300 hp at 220...240 V AC 50/60 Hz for 3 phase motors 250 hp at 200...208 V AC 50/60 Hz for 3 phase motors","Irms rated making capacity":"6740 A for power circuit","Power dissipation per pole":"48 W AC-3 120 W AC-1","[Uc] control circuit voltage":"48 V AC 50...400 Hz 48 V DC standard","[Ui] rated insulation voltage":"1000 V IEC 60158-1 1000 V IEC 60947-4 1000 V BS 775 1500 V VDE 0110 group C","Control circuit voltage limits":"Latching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc","Power Pole Contact Composition":"4 NO","[Ie] rated operational current":"630 A (at 1000 A (at 560 A (at <104 °F (40 °C)) at <= 440 V AC AC-4","[Ue] rated operational voltage":"1000 V AC 25...200 Hz","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"5...158 °F (-15...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"5.05 kA 104 °F (40 °C) - 1 s 5.05 kA 104 °F (40 °C) - 5 s 5.05 kA 104 °F (40 °C) - 10 s 4400 A 104 °F (40 °C) - 30 s 3400 A 104 °F (40 °C) - 1 min 2200 A 104 °F (40 °C) - 3 min 1600 A 104 °F (40 °C) - 10 min","[Ith] conventional free air thermal current":"1000 A (at 104 °F (40 °C)) for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3416f17ecf11dc08b01ac8c014cc373f.pdf","sourceUrl":"https://www.se.com/us/en/product/CR1F6304E7/bistable-contactor-cr1f-4p-ac1-440v-1000-a-coil-48-v/"},"ai":{"faq":[{"question":"What are the key ratings for CR1F6304E7?","answer":"Rated operational current is 630 A in AC-3 duty, with a rated operational voltage of 1000 V AC. The control circuit is 48 V AC/DC. It has four normally-open poles and handles motor loads up to 450 kW at 690 V or 800 hp at 575-600 V."},{"question":"What compliance standards does CR1F6304E7 meet?","answer":"It complies with IEC 60947-4, BS 5424, VDE 0660, NF C 63-110, and JEM 1038. The front face is rated IP20 per IEC 60529."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CR1F6304E7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CR1F6304E7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}