{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CR1F6304EZ7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CR1F6304EZ7","canonicalUrl":"https://aoctrl.com/schneider/CR1F6304EZ7","factsUrl":"https://aoctrl.com/api/mcp/products/CR1F6304EZ7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F CR1F6304EZ7, magnetic latching contactor, 4-pole 4 NO, 630 A rated operational current (AC-4 at ≤440 V), 48 V DC control.","salesMarkdown":"The Schneider Electric CR1F6304EZ7 is a TeSys F magnetic latching contactor — a 4-pole, 4 NO device rated for motor control and resistive loads across AC-1, AC-3, and AC-4 utilisation categories. Its magnetic latching mechanism holds the main poles closed without continuous coil power; the coil draws 620 W DC during the latching pulse and 45 W DC during the unlatching pulse, then drops to zero holding current. This makes it suited for applications where sustained coil power is undesirable or where a contactor must stay closed through a control-power interruption. For AC-3 (starting/running) the conventional free-air thermal current Ith is 1000 A at 40 °C, which is the thermal limit for the main pole assembly. Motor power spans from 200 kW at 220–230 V up to 450 kW at 690 V and 1000 V AC, 50/60 Hz. The UL/CSA horsepower ratings follow a similar curve: 800 hp at 575–600 V for 3-phase motors. The control circuit is 48 V DC with a latching range of 0.85–1.1 Uc and unlatching range of 0.85–1.1 Uc. Operating time is 40–80 ms latching, 50–100 ms unlatching. The rated insulation voltage Ui is 1000 V per IEC 60947-4 and BS 775, with an impulse withstand Uimp of 8 kV. Short-time withstand Icw is 5050 A for 1 s, tapering to 1600 A for 10 min — this defines how long the contactor can carry fault current while a breaker clears. This is a large-frame contactor — 15.3 in wide, 12.0 in tall, 10.04 in deep — designed for bolted bus-bar connection via two 60 x 5 mm bars per pole. The tightening torque on the main connections is 513.3 lbf·in (58 N·m). It is not a DIN-rail snap-on device; it mounts on a backplate or chassis, and the bus-bar interface means it integrates into a switchboard or motor control centre lineup. The associated fuse rating is 630 A aM or gG at ≤440 V, or BS88 at 1000 A — use that as the starting point for coordination studies.","metaTitle":"Schneider TeSys F CR1F6304EZ7 Magnetic Latching Contactor, 6","metaDescription":"Schneider Electric TeSys F CR1F6304EZ7 magnetic latching contactor, 4-pole, 630 A rated operational current in AC-4, 450 kW at 690 V. Current lifecycle stage. Sourced to order agai","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"10.04 in (255 mm)","Range":"TeSys","Width":"15.3 in (389 mm)","title":"CR1F6304EZ7","Height":"12.0 in (304 mm)","Category":"22331-CTR,F-LINE,DC,OPEN,NONREV","description":"TeSys F magnetic latching contactor - 4P - 1000 A - 48 V DC coil - low consum.","Product name":"TeSys F","Motor power kW":"450 kW at 1000 V AC 50/60 Hz 450 kW at 690 V AC 50/60 Hz 400 kW at 500...660 V AC 50/60 Hz 400 kW at 440 V AC 50/60 Hz 375 kW at 415 V AC 50/60 Hz 335 kW at 380...400 V AC 50/60 Hz 200 kW at 220...230 V AC 50/60 Hz","Operating time":"40...80 ms latching 50...100 ms unlatching","lifecycle_stage":"current","Average impedance":"0.12 mOhm - Ith 1000 A 50 Hz","Device short name":"CR1F","Poles description":"4P","Tightening torque":"513.3 lbf.in (58 N.m)","Device Application":"Control","Operating altitude":"9842.52 ft (3000 m) without derating","Average Consumption":"620 W DC latching 45 W DC unlatching","Protective treatment":"TH","Utilisation category":"AC-4 AC-1 AC-3","Contactor application":"Motor control Resistive load","Mechanical durability":"1 Mcycles","Nbr. of units in pkg.":"1","Associated fuse rating":"630 A aM at 1000 A BS88 at 1000 A gG at <= 440 V","Maximum operating rate":"120 cyc/h 104 °F (40 °C)","Connections - terminals":"bars 2 60 x 5 mm","Rated breaking capacity":"6300 A at 220...440 V 5400 A at 500 V 3200 A at 1000 V 4600 A at 660/690 V","Product or Component Type":"Magnetic latching contactor","motor power HP (UL / CSA)":"800 hp at 575...600 V AC 50/60 Hz for 3 phase motors 600 hp at 460...480 V AC 50/60 Hz for 3 phase motors 300 hp at 220...240 V AC 50/60 Hz for 3 phase motors 250 hp at 200...208 V AC 50/60 Hz for 3 phase motors","Irms rated making capacity":"6740 A","Power dissipation per pole":"48 W AC-3 120 W AC-1","[Uc] control circuit voltage":"48 V DC low consumption","[Ui] rated insulation voltage":"1000 V IEC 60158-1 1000 V IEC 60947-4 1000 V BS 775 1500 V VDE 0110 group C","Control circuit voltage limits":"Latching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc","Power Pole Contact Composition":"4 NO","[Ie] rated operational current":"630 A (at 1000 A (at 560 A (at <104 °F (40 °C)) at <= 440 V AC AC-4","[Ue] rated operational voltage":"1000 V AC 25...200 Hz","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"5...158 °F (-15...70 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"4400 A 104 °F (40 °C) - 30 s 3400 A 104 °F (40 °C) - 1 min 2200 A 104 °F (40 °C) - 3 min 1600 A 104 °F (40 °C) - 10 min 5050 A 104 °F (40 °C) - 1 s 5050 A 104 °F (40 °C) - 5 s 5050 A 104 °F (40 °C) - 10 s","[Ith] conventional free air thermal current":"1000 A (at 104 °F (40 °C))"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/212bd453da115cbe207f2bcb3d7db633.pdf","sourceUrl":"https://www.se.com/th/en/product/CR1F6304EZ7/tesys-f-magnetic-latching-contactor-4p-1000-a-48-v-dc-coil-low-consum-/"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"Rated operational current Ie is 630 A in AC-4 at ≤440 V. Conventional free-air thermal current Ith is 1000 A at 40 °C. Motor power reaches 450 kW at 690 V AC. Control voltage is 48 V DC latching. Rated insulation voltage Ui is 1000 V per IEC 60947-4."},{"question":"What compliance documentation is available for this part?","answer":"The insulation voltage ratings reference IEC 60158-1, IEC 60947-4, BS 775, and VDE 0110 group C. The protective treatment is TH (tropicalised). For specific RoHS/REACH/UL documentation, request the manufacturer's compliance declaration with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CR1F6304EZ7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CR1F6304EZ7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}