{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CV1BF0Z1FMD00","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CV1BF0Z1FMD00","canonicalUrl":"https://aoctrl.com/schneider/CV1BF0Z1FMD00","factsUrl":"https://aoctrl.com/api/mcp/products/CV1BF0Z1FMD00","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys B contactor, CV1BF0Z1FMD00, 1 NC pole, 80 A rated operational current, 220 V DC coil, motor power 37 kW at 400 V AC (AC-3).","salesMarkdown":"The Schneider Electric TeSys B contactor CV1BF0Z1FMD00 is a DC-coil, single-pole normally-closed (1 NC) switching device rated for 80 A in both AC-1 and AC-3 utilisation categories. The 80 A figure is the conventional free-air thermal current (Ith) at 40 °C, which also matches the rated operational current (Ie) for the control circuit — so the contactor carries its full rating without derating in open panel air. At 400 V AC, AC-3 duty, it handles a 37 kW motor load; that is the headline selection number for a three-phase induction motor on a conveyor, pump, or fan. The 220 V DC coil means it is intended for a DC control bus — common in 220 VDC substation or industrial DC distribution schemes — and the control circuit voltage limits (0.85 to 1.1 Uc for pickup, 0.1 to 0.65 Uc for dropout at 55 °C) define the reliable operating window: the coil will pull in at 187 V DC minimum and drop out below 143 V DC. ## Where it is used and how it integrates This contactor belongs to the TeSys B series, designed for motor starting and resistive load switching in control panels. The IP00 protection rating means it is intended for enclosure mounting — it has no integral housing and must be installed inside a panel that provides the environmental seal. The single NC pole is the normally-closed main contact; this is unusual for a power contactor (most are normally-open) and is specified for applications where the load must be connected when the coil is de-energised — for example, a bypass circuit or a fail-closed valve. Power connections are bolted, sized for cable lugs up to 25 mm² or connector up to 16 mm², with a tightening torque of 9 N.m. The control circuit accepts wire up to 25 mm² on a single lug or 2 x 16 mm² on a connector. The rated short-time withstand current (Icw) is 640 A for 5 seconds at 40 °C — this is the fault current the contactor can carry momentarily without welding its contacts, relevant for coordination with upstream fuses or breakers. The associated fuse recommendation is 80 A aM or 125 A g1 at up to 400 V for the control circuit. Mechanical durability is 5 million cycles; the maximum operating rate is 120 cycles per minute at 55 °C. Power dissipation per pole is 7.6 W in AC-3 and 9.6 W in AC-1 — useful for thermal calculations inside a sealed enclosure.","metaTitle":"TeSys CV1BF0Z1FMD00 Contactor, 80A AC-3, 220V DC Coil, 1 NC","metaDescription":"TeSys B contactor CV1BF0Z1FMD00, 37 kW at 400V AC-3, 80 A rated, 220 V DC coil, 1 NC pole. Active production. IEC 60947-4. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Range":"TeSys","title":"CV1BF0Z1FMD00","Category":"18402-WORLD SERVICE PARTS(CONTROL ACCESS)","Standards":"IEC 60947-4 EN 60947-4","description":"contactor TeSys CV1BF -without pole - 1N/C- 80A - coil 220 V DC","Product name":"TeSys B","Motor power kW":"37 kW at 400 V AC (AC-3)","lifecycle_stage":"current","Shock resistance":"4 gn 2 gn","Device short name":"CV1BF","Inrush power in W":"20...27 W","Poles description":"1P","Tightening torque":"Power circuit 79.7 lbf.in (9 N.m) cable with lug 0.04 in² (25 mm²) Power circuit 79.7 lbf.in (9 N.m) cable connector 0.02 in² (16 mm²)","Operating altitude":"6561.68 ft (2000 m)","Control circuit type":"DC","Utilisation category":"AC-1 AC-3","Vibration resistance":"4 gn 2 gn","Contactor application":"Motor Resistive circuits, heating, lighting","Mechanical durability":"5000000 cycles","Associated fuse rating":"80 A aM at 125 A g1 at <= 400 V for control circuit","Maximum operating rate":"120 cyc/mn 131 °F (55 °C)","Connections - terminals":"Control circuit cable with lug 1 x 0.04 in² (25 mm²) Control circuit cable connector 2 x 0.02 in² (16 mm²) Power circuit bolted connection","IP degree of protection":"IP00IEC 60529","Pole contact composition":"1 NC","Product or Component Type":"Contactor","Irms rated making capacity":"1600 A at 690 V DC for control circuit conforming to IEC 60947-4-1","Power dissipation per pole":"7.6 W AC-3 9.6 W AC-1","Rated operational power in W":"300 W 24 V 1000000 cycles - control circuit 115 W 24 V 3000000 cycles - control circuit 45 W 24 V 10000000 cycles - control circuit","[Uc] control circuit voltage":"220 V DC","[Ui] rated insulation voltage":"690 V IEC 60947-4","Control circuit voltage limits":"Operational: 0.85...1.1 Uc (at Drop-out: 0.1...0.65 Uc (at <131 °F (55 °C))","Hold-in power consumption in W":"20...27 W","[Ie] rated operational current":"80 A AC for control circuit","[Ue] rated operational voltage":"Control circuit 690 V AC","Current rating code of contactor":"BF","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"23...131 °F (-5...55 °C)","[Icw] rated short-time withstand current":"640 A 104 °F (40 °C) - 5 s for control circuit 640 A 104 °F (40 °C) - 10 s for control circuit 380 A 104 °F (40 °C) - 30 s for control circuit 320 A 104 °F (40 °C) - 60 s for control circuit 200 A 104 °F (40 °C) - 180 s for control circuit 130 A 104 °F (40 °C) - 600 s for control circuit","[Ith] conventional free air thermal current":"80 A (at 104 °F (40 °C)) for control circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/us/en/product/CV1BF0Z1FMD00/contactor-tesys-cv1bf-without-pole-1n-c-80a-coil-220-v-dc/"},"ai":{"faq":[{"question":"What is the rated motor power for this contactor?","answer":"37 kW at 400 V AC in AC-3 duty."},{"question":"What coil voltage does this contactor use?","answer":"220 V DC."},{"question":"What standards does the CV1BF0Z1FMD00 comply with?","answer":"IEC 60947-4 and EN 60947-4."},{"question":"What is the contact configuration?","answer":"1 normally-closed (NC) pole."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CV1BF0Z1FMD00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CV1BF0Z1FMD00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}