{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"CV1BJ2J0ZMD22","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"CV1BJ2J0ZMD22","canonicalUrl":"https://aoctrl.com/schneider/CV1BJ2J0ZMD22","factsUrl":"https://aoctrl.com/api/mcp/products/CV1BJ2J0ZMD22","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys B contactor, CV1BJ2J0ZMD22, 2-pole, 470 A AC-3 at 690 V, 220 V DC coil, IP00.","salesMarkdown":"The Schneider Electric TeSys B CV1BJ2J0ZMD22 is a 2-pole power contactor rated for 470 A in AC-3 duty at 690 V AC, with a 220 V DC control coil. The AC-1 rating covers resistive loads like heating elements, where the current is lower-stress on the contacts. The 220 V DC coil has an operational range of 0.85 to 1.1 Uc (187 to 242 V DC) and drops out between 0.1 and 0.65 Uc (22 to 143 V DC) at 55 °C. That dropout margin is generous — it stays pulled in through a significant dip, but drops reliably when the control signal is removed. The coil is DC, so verify polarity and free-wheel diode placement if you're wiring it into an existing AC-coil panel. Rated insulation voltage (Ui) is 690 V, matching the operational voltage — no derating needed for standard 400/480 V systems, and it handles 690 V line-to-line without issue. The 2-pole configuration with 2 NO main poles is typical for single-phase or DC switching, or for three-phase motor circuits where a third pole is handled externally. The auxiliary contact block is built in: 2 NO + 2 NC instantaneous contacts, which covers feedback and interlocking without an add-on block. That's a fast cycling rate — suitable for applications like conveyor indexing or press feeders where the contactor opens and closes frequently. The vibration resistance of 4 gn (2 gn in some axes) and shock resistance of 4 gn / 2 gn mean it holds up on machinery that sees moderate mechanical shock, but it's not rated for extreme impact environments. Maximum operating altitude is 2000 m without derating. The contactor is certified to EN 60947-4 and IEC 60947-4, which covers the full scope of low-voltage switchgear and controlgear for motor starting and switching. These standards define the AC-1 and AC-3 ratings, the insulation voltage, and the operational performance. The part is classified under Schneider's 18402-WORLD SERVICE PARTS (CONTROL ACCESS) category, which is their internal service-parts coding for control components.","metaTitle":"Schneider TeSys CV1BJ2J0ZMD22 Contactor, 470A AC-3, 220VDC C","metaDescription":"Active-production TeSys B contactor, 2-pole, 470A AC-3 at 690V, 220VDC coil. EN/IEC 60947-4 rated. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Range":"TeSys","title":"CV1BJ2J0ZMD22","Category":"18402-WORLD SERVICE PARTS(CONTROL ACCESS)","Standards":"EN 60947-4 IEC 60947-4","description":"contactor TeSys CV1BJ - 2 poles - AC-3 690 V 470A - coil 220 V DC","Product name":"TeSys B","lifecycle_stage":"current","Shock resistance":"4 gn 2 gn","Device short name":"CV1BJ","Poles description":"2P","Operating altitude":"6561.68 ft (2000 m)","Control circuit type":"DC","Utilisation category":"AC-3 AC-1","Vibration resistance":"4 gn 2 gn","Contactor application":"Resistive circuits, heating, lighting Motor","Mechanical durability":"5000000 cycles","Maximum operating rate":"120 cyc/mn 131 °F (55 °C)","Auxiliary contacts type":"Instantaneous 2 NO + 2 NC","IP degree of protection":"IP00IEC 60529","Pole contact composition":"2 NO","Product or Component Type":"Contactor","[Uc] control circuit voltage":"220 V DC","Auxiliary contact composition":"2 NO + 2 NC","[Ui] rated insulation voltage":"690 V IEC 60947-4","Control circuit voltage limits":"Operational: 0.85...1.1 Uc (at Drop-out: 0.1...0.65 Uc (at <131 °F (55 °C))","[Ie] rated operational current":"470 A AC for power circuit","[Ue] rated operational voltage":"690 V AC","Current rating code of contactor":"BJ","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/844f7781574243d79d365916d0aca897.pdf","sourceUrl":"https://www.se.com/in/en/product/CV1BJ2J0ZMD22/contactor-tesys-cv1bj-2-poles-ac3-690-v-470a-coil-220-v-dc/"},"ai":{"faq":[{"question":"What are the key ratings I need to check for fit?","answer":"The headline rating is 470 A in AC-3 (motor switching) at 690 V AC. The coil is 220 V DC with a dropout range of 0.1 to 0.65 Uc. It's a 2-pole contactor with 2 NO main poles and built-in 2 NO + 2 NC auxiliary contacts. Insulation voltage is 690 V, and it's rated for 5 million mechanical cycles."},{"question":"What standards does this contactor comply with?","answer":"It's certified to EN 60947-4 and IEC 60947-4, the governing standards for contactors and motor-starters. The AC-1 and AC-3 utilisation categories are defined under these standards."},{"question":"What is the TeSys range and where does this part fit?","answer":"The CV1BJ2J0ZMD22 belongs to the TeSys B range, which is Schneider's family of contactors for motor control and resistive load switching. The 'BJ' current rating code corresponds to the 470 A AC-3 rating, placing it in the higher-current segment of the TeSys B line."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/CV1BJ2J0ZMD22","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/CV1BJ2J0ZMD22 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}