{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"DPE40G7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"DPE40G7","canonicalUrl":"https://aoctrl.com/schneider/DPE40G7","factsUrl":"https://aoctrl.com/api/mcp/products/DPE40G7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys DPE, IEC contactor, 40 A, 3 poles, 25 HP at 480 V AC, 120 V AC 50/60 Hz coil, screw terminals.","salesMarkdown":"The 40 A figure is the rated operational current (Ie) in AC-3 duty — the category that governs switching of squirrel-cage motors during starting and running. That means it handles a 40 A motor load under the standard IEC 60947-4-1 test profile, not just a resistive heater bank. For resistive loads (AC-1), the same contactor can carry higher current, but the AC-3 rating is the one that decides motor fit. The 120 V AC 50/60 Hz coil matches standard North American control voltages; the coil draws from the signalling circuit, which is rated for 25...400 Hz, so it works on both 50 and 60 Hz supplies without derating. Rated insulation voltage (Ui) is 690 V for the power circuit per IEC 60947-4-1 and 600 V per cUL — so the contactor is suitable for 480 V and 600 V class systems. The 3-pole block with one normally-open auxiliary contact (1 NO) gives you one feedback or status signal without needing an add-on block. The screw terminals accept power conductors from 2.5 mm² up to 25 mm² (flexible with or without cable end) and control conductors from 1 mm² to 4 mm². Torque the power terminals to 7 N·m for the larger wire range, 5 N·m for the smaller — the control terminals take 1.7 N·m. Operating altitude is limited to 2000 m; above that, dielectric strength and air clearance derate. The contactor is rated for vibration: 2 Gn open, 4 Gn closed (5...300 Hz), and shock: 10 Gn open, 15 Gn closed (11 ms). That's enough for most industrial machinery but not for extreme mobile or marine applications without additional isolation. Climatic withstand per IACS and IEC 60947-1 Annex Q category D confirms it handles damp heat and cyclic humidity typical of non-condensing environments. Certified to IEC 60947-4-1 (contactor standard for motor starters), IEC 60947-5-1 (control circuit devices), EN 60947-4-1, EN 60947-5-1, UL 60947-4-1, and CSA C22.2 No 14. That covers the major industrial control standards for North America and Europe. The lifecycle status is Active, so this is a current-production part, not an NRND or obsolete line.","metaTitle":"Schneider Electric DPE40G7 Easy TeSys Contactor, 40A, 3P, 12","metaDescription":"Active IEC contactor, Easy TeSys DPE, 40A rated operational current, 3P, 25HP at 480V AC, 120V AC 50/60Hz coil. UL/CSA/IEC certified. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"4.8 in (122 mm)","Range":"Easy TeSys","Width":"2.2 in (55 mm)","title":"DPE40G7","Height":"4.8 in (122 mm)","Category":"US10I1222329","Standards":"CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 60947-4-1","description":"IEC contactor,Easy TeSys DPE,nonreversing,40A,3P,25HP at 480V AC,120V AC 50/60Hz coil","Product name":"Easy TeSys DPE","Fire resistance":"1562 °F (850 °C) IEC 60695-2-1","lifecycle_stage":"current","Mounting Support":"Rail Plate","Pollution degree":"3","Device short name":"DPE","Poles description":"3P","Tightening torque":"Power circuit 62.0 lbf.in (7 N.m) screw connectors 0.02...0.04 in² (16...25 mm²) hexagonal 0.2 in (4 mm) Power circuit 44.3 lbf.in (5 N.m) screw connectors 0.004...0.02 in² (2.5...16 mm²) hexagonal 0.2 in (4 mm) Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2 Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2","Climatic withstand":"IACS E10 IEC 60947-1 Annex Q category D","Operating altitude":"0...6561.68 ft (0...2000 m)","Overvoltage category":"III","Utilisation category":"AC-1 AC-3","Contactor application":"Motor control Resistive load","Mechanical robustness":"Vibrations contactor open 2 Gn, 5...300 Hz) Vibrations contactor closed 4 Gn, 5...300 Hz) Shocks contactor open 10 Gn for 11 ms) Shocks contactor closed 15 Gn for 11 ms)","Nbr. of units in pkg.":"1","Connections - terminals":"Power circuit: screw connection 1 0.004...0.04 in² (2.5...25 mm²) - cable stiffness: flexible without cable end Power circuit: screw connection 2 0.004...0.02 in² (2.5...16 mm²) - cable stiffness: flexible without cable end Power circuit: screw connection 1 0.004...0.04 in² (2.5...25 mm²) - cable stiffness: flexible with cable end Power circuit: screw connection 2 0.004...0.02 in² (2.5...10 mm²) - cable stiffness: flexible with cable end Power circuit: screw connection 1 0.004...0.04 in² (2.5...25 mm²) - cable stiffness: solid without cable end Power circuit: screw connection 2 0.004...0.02 in² (2.5...16 mm²) - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid without cable end","IP degree of protection":"IP20 front face IEC 60529","Pole contact composition":"3 NO","Product or Component Type":"Contactor","Signalling circuit frequency":"25...400 Hz","Auxiliary contact composition":"1 NO","[Ui] rated insulation voltage":"Power circuit 690 V IEC 60947-4-1 Power circuit 600 V cUL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V cUL","[Ie] rated operational current":"60 A (at 40 A (at 10 MOhm for signalling circuit","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"-40...140 °F (-40...60 °C)","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$85.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f54fb897c668efd9a854bac18efb861d.pdf","sourceUrl":"https://www.se.com/us/en/product/DPE40G7/iec-contactoreasy-tesys-dpenonreversing40a3p25hp-at-480v-ac120v-ac-50-60hz-coil/"},"ai":{"faq":[{"question":"What is the closest alternative to the DPE40G7 in the Easy TeSys family?","answer":"Within the Easy TeSys DPE range, the closest sibling is the DPE40G7 itself — it is the 40 A, 120 V AC coil variant. If you need a different coil voltage (e.g., 24 V AC, 240 V AC) or a higher current rating (e.g., 50 A or 65 A), the DPE series offers those order codes with the same physical footprint and terminal layout. The deciding factor is coil voltage and rated operational current — not form factor or mounting."},{"question":"What is the depth of the DPE40G7?","answer":"The depth is 4.8 in (122 mm). Width is 2.2 in (55 mm), height is 4.8 in (122 mm)."},{"question":"What compliance documentation does Schneider provide for the DPE40G7?","answer":"The contactor carries certifications to IEC 60947-4-1, IEC 60947-5-1, EN 60947-4-1, EN 60947-5-1, UL 60947-4-1, and CSA C22.2 No 14. Fire resistance is tested per IEC 60695-2-1 at 850 °C. RoHS and REACH declarations are standard for Schneider's Easy TeSys range; request the specific declaration of conformity or material data sheet with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/DPE40G7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/DPE40G7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}