{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"DPER35","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"DPER35","canonicalUrl":"https://aoctrl.com/schneider/DPER35","factsUrl":"https://aoctrl.com/api/mcp/products/DPER35","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy TeSys DPER, thermal overload relay, 30-38 A, Class 10, 1 NO + 1 NC auxiliary contacts, IP20.","salesMarkdown":"The Schneider Electric DPER35 is an Easy TeSys thermal overload relay with a 30...38 A adjustment range and Class 10 trip characteristic per IEC 60947-4-1. The 1 NO + 1 NC auxiliary contact set gives you one normally-open signal for the PLC or status lamp and one normally-closed series link in the contactor coil circuit, which is the conventional way to break the coil on a trip. ## Deployment and integration Mounts directly under a contactor or separately with specific accessories. The screw-clamp terminals accept up to 10 mm² solid or 6 mm² flexible with cable end on the power circuit. Phase-failure sensitivity is built in: the relay trips at 130 % of Ir on two phases when the third is at zero, so a lost phase on a conveyor motor will not go unnoticed. ## Sourcing takeaway This is an active, standard-catalogue part from the Easy TeSys range. For a BOM line specifying DPER35, the fit is confirmed by the 30-38 A range and Class 10 trip curve.","metaTitle":"Schneider Electric DPER35 Easy TeSys Thermal Overload Relay,","metaDescription":"Schneider Electric DPER35 Easy TeSys thermal overload relay, 30-38 A adjustment range, Class 10 trip, 1 NO + 1 NC aux contacts. Active lifecycle. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Overload Relays"],"specifications":{"Depth":"2.8 in (70 mm)","Range":"Easy TeSys","Width":"1.8 in (45 mm)","title":"DPER35","Height":"2.6 in (66 mm)","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1","description":"Thermal overload relay,Easy TeSys DPER,30-38A,class 10","Control type":"Red push-button stop Blue push-button reset","Network type":"DC AC","Product name":"Easy TeSys DPER","Protection type":"BS fuse 5 A - control circuit GB2 circuit breaker 5 A - control circuit GG fuse 5 A - control circuit","Surge withstand":"6 kV IEC 60801-5","lifecycle_stage":"current","Mounting support":"Separate, with specific accessories Under contactor","Shock resistance":"15 gn 11 ms IEC 60068-2-7","Device short name":"DPER","Network Frequency":"0...400 Hz","Relay application":"Overload protection","Tightening torque":"Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals","Tripping threshold":"1.14 +/- 0.06 Ir IEC 60947-4-1","Dielectric strength":"1.89 kV 50 Hz IEC 60947-1","Permissible current":"1.5 A 240 V AC-15 signalling circuit 0.1 A 250 V DC-13 signalling circuit","Protective treatment":"TH IEC 60068","Vibration resistance":"6 gn on plate IEC 60068-2-6","Nbr. of units in pkg.":"1","Thermal overload class":"Class 10 IEC 60947-4-1","Connections - terminals":"Control circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) flexible without cable end Control circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) flexible with cable end Control circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) solid without cable end Power circuit screw clamp terminals 1 0.004...0.02 in² (2.5...10 mm²) flexible without cable end Power circuit screw clamp terminals 1 0.002...0.009 in² (1.5...6 mm²) flexible with cable end Power circuit screw clamp terminals 1 0.004...0.02 in² (2.5...10 mm²) solid without cable end","IP degree of protection":"IP20 conforming to IEC 60529","Temperature compensation":"-4...140 °F (-20...60 °C)","Phase failure sensitivity":"Tripping current 130 % of Ir on two phase, the last one at 0","Product or Component Type":"Thermal overload relay","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"Power circuit 600 V cUL Power circuit 690 V IEC 60947-4-1","[Ue] rated operational voltage":"690 V AC 0...400 Hz power circuit IEC 60947-4-1","Ambient Air Temperature for Storage":"-76...158 °F (-60...70 °C)","Thermal protection adjustment range":"30...38 A","Ambient air temperature for operation":"-4...140 °F (-20...60 °C) without derating IEC 60947-4-1","[Uimp] rated impulse withstand voltage":"6 kV","[Ith] conventional free air thermal current":"5 A signalling circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/22a19bd0dac957bc8300cc3a24bc2bde.pdf","sourceUrl":"https://www.se.com/us/en/product/DPER35/thermal-overload-relayeasy-tesys-dper3038aclass-10/"},"ai":{"faq":[{"question":"What is the closest alternative to DPER35 in the Easy TeSys family?","answer":"The DPER35 is part of the Easy TeSys DPER series. Within the same family, the closest alternative would be a DPER relay with a different adjustment range — for example, a DPER32 for 23-32 A or DPER38 for 37-50 A — but these are not pin-compatible; the mounting and terminal layout are shared, but the current range must match the motor FLA."},{"question":"What compliance documentation does Schneider provide for DPER35?","answer":"The DPER35 is certified to UL 60947-4-1, UL 60947-5-1, EN/IEC 60947-4-1, and EN/IEC 60947-5-1. These standards cover the product safety and performance requirements for North American and European markets. RoHS and REACH compliance is standard for current-production Schneider Easy TeSys products."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/DPER35","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/DPER35 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}